Problem 

Cause 

Action 

Ref # 

Power Button on 
Digital Controller 
face is depressed but 
doesn’t turn on. 

1.   Power cord is not plugged in. 
 
 
2.  Circuit breaker is tripped off in the 
site's breaker box. 
 
 
3.  Transformer has taken an 
electrical surge and is damaged. 
 
 
 
4.  Check voltage on the secondary 
side of the Transformer. If you read 
12VDC then you are receiving 
voltage to the controller. 
 
5.  Possible blown fuse. 
 

1. Plug the power cord into wall 
receptacle and power button. 
 
2. Reset circuit breaker that the 
grill is plugged into. Depress 
Power Button to turn on. 
 
3. Replace Transformer after you 
check secondary side of 
transformer. If working properly, 
you should receive 12vdc. 
 
4. Replace controller. Controller 
should be on once the power 
button is depressed. 
 
 
5. Replace fuse. 
 

 
68 
 
 
----- 
 
 
 
91 
 
 
 
 
85 
 
 
 
105 

Digital controller's 
LED's are scrambled 
or randomly erratic. 
If when turning on, 
the display will first 
go to segment check 

1.  Possibly a component on the 
Digital controller is damaged. 
 
2. Control needs to reset. 

1. Replace digital controller. 
 
 
2. While unit is on unplug unit, 
wait for 1 min. Then plug machine 
on again  and depress the power 
button. 
 

----- 
 
 
 
85 

Digital controller on 
startup goes through 
LED segment check 
(8888) then to 
version # and then 
loops back to to the 
above reboot. 

The relay driver on the digital control 
may be blown. 

Replace digital controller. 

85 

Digital display shows 
PROB. No heat on 
Upper Platen. 
 

Sensor lost it's continuity as shown 
on a muti-meter. 

Disconnect prob that is open (no 
continuity as shown on a multi- 
meter. Must replace sensor 
(RTD). Do not cut and splice new 
sensor. Install new 2000 ohm 
RTD sensor to under side of heat 
platen and reconnect to the 
controller. 
 

41 

When depressing the  The tactile buttons under the overlay  Carefully (no too much at one 

 

Summary of Contents for Endurance Pro X2

Page 1: ...Operations Manual Endurance Pro X2 Dual Heat Semi automatic Dough Press Model DP2010SE WWW PROLUXE COM Version 41219...

Page 2: ...Only industrial extension cords with proper wire size 2 5 sq mm shall be used Make sure there is a proper electrical wall outlet located within reach of the cord and plug attached to the press Place...

Page 3: ...other warranties expressed or implied in law or in fact including the warranties of merchantability and fitness for a particular use and is accepted such by the purchaser in taking delivery of this pr...

Page 4: ...faces while operating the machine Caution During normal operation the base of the machine must be installed or placed above the wall socket When servicing or cleaning the machine make sure that the po...

Page 5: ...have the correct type of electrical current or serious damage could occur 2 Press the power button the green light above will illuminate when powered on 3 Set your desired temperature on the control p...

Page 6: ...oil across lower platen with paper towel 4 Wipe oil across upper platen 5 Mix a warm dish soap and water solution 6 Soak washcloth and wring to remove excess water 7 Wipe lower and upper platen with d...

Page 7: ...rt 3 Squeeze handle of grease gun This will force the grease into the piston The lubricant use must be USDA H I authorized for food machinery This lubricant can be ordered through Proluxe part 110 002...

Page 8: ...place fuse 68 91 85 105 Digital controller s LED s are scrambled or randomly erratic If when turning on the display will first go to segment check 1 Possibly a component on the Digital controller is d...

Page 9: ...te temperature 2 Beeper on digital control board failed 1 Replace the relay 2 Replace digital controller board 92 85 If setpoint is reached but slightly off in temperature Offset may need to be calibr...

Page 10: ...9...

Page 11: ...10...

Page 12: ...17 1 15 HANDLE SWING AWAY 11023004501 1 16 CAP VINYL ADJUSTMENT SCREWS SC0687 4 17 SPRING DIE RED MEDIUM HEAVY DUTY 11020106 4 18 ASSEMBLY BASE 1106191101 1 19 SHIM GEAR RACK 110144120 1 20 COVER PLAT...

Page 13: ...2 NUT HEX 6 32 NH632 8 53 WASHER 6 INTERNAL TOOTH LOCK WLIT6 8 54 POWER DISTRIBUTION CABLE 11017815467 1 55 WASHER 8 INTERNAL TOOTH LOCK WLIT8 4 56 NUT HEX 8 32 NH832 4 57 TERMINAL BLOCK BASE 5 DOUBLE...

Page 14: ...6 X 3 4 SB381634 2 94 CONTACT N O SCREW TYPE GE 110101751 1 95 SWITCH MOM P S OP SCREW ON GE P9XPLOSO 1 96 BUTTON BLACK MUSHROOM SCREW ON GE P9ARB3N 1 97 MANUAL DP2010 MDP2010SE 1 98 BUSHING ALIGNMENT...

Page 15: ...NSUL BLUE 1670FIN 1 127 SCREW SET 1 4 20 X 1 2 SST142012 1 128 EYELET END MACHINED 1101098154C5 1 129 GAS SPRING 30LB FORCE DP12810 1 130 CLEVIS STEEL DP12809 1 131 CLEVIS PIN 1 4 DIA X 3 4 LONG 11010...

Page 16: ...15...

Page 17: ...rnable unless defective within the terms of this warranty In no event shall Proluxe be liable for consequential damages arising out of the failure of any of its products if operated improperly or caus...

Page 18: ...cing Prices specifications model numbers capacities and accessories are subject to change without notice 5 F reight Routing Method of shipment will be determined by Proluxe unless otherwise advised by...

Reviews: