Page 1: ...http prolux net ua 1 MATRIX BAR 2 IP Wi USER MANUAL...

Page 2: ...obe eotic gradual change fading and so on It uses power switch performs low weight and consumption stable capability and long life International standard DMX 512 signal is requested Packing list Conte...

Page 3: ...Input voltage AC 100V 264V 47 63HZ Power consumption 60W Lamp Type 25W LED 5 in 1 RGBWA 2PCS Life span 50000 100000hours PWM Dimmer 1500HZ 16666 grades Control Signal DMX512 Control mode standalone s...

Page 4: ...trobe slow to fast 116 130 No strobe 131 170 Electronic Sinewave slow to fast 171 210 Opening pulse slow to fast 211 250 Closing pulse slow to fast 251 255 No strobe CH8 CH8 Prior to CH10 0 5 No effec...

Page 5: ...d 0 Green up Blue full White 0 proportional 51 Light Blue Red 0 Green full Blue full White 0 step 52 90 Red 0 Green full Blue down White 0 proportional 91 Green Red 0 Green full Blue 0 White 0 step 92...

Page 6: ...smooth 61 70 Square law curve and smooth 71 80 Inverse square law curve and smooth 81 90 S curve and smooth 91 255 Use the dimmer mode which menu had set up 6 DISPLAY OPERATION INSTRUCTION MENU acces...

Page 7: ...eset YES NO KEY BAT battery output HIGH MIDDLE LO W CAL Calibration R 0 25 G 0 255 B 0 255 A 0 255 W 0 255 USE YES NO CHMD Channel mode 11CH 8CH 6CH 5CH DIM Dimming mode LIN linear SQR square law ISQR...

Page 8: ...RUN RUN RUN AT05 RUN ATSP Auto speed 0 255 S CHS1 Chase 1 RUN CHS2 Chase 2 RUN CHS3 Chase 3 RUN SOU1 Sound1 RUN Sound change color SOU2 Sound2 RUN Sound Strobe white color only PROG Program CHS1 Chase...

Page 9: ...in these position it will not return back to the default display after two minutes 6 1 DMX ADDRESS SETTING 1 Press the ENTER button in ADDR menu then enter to the DMX address setting 2 Press the UP D...

Page 10: ...ss the UP DOWN button to set up the 0 255 numerical value 4 On the USE interface pressing YES button means valid NO means invalid 5 Press the ENTER button to escape and save Illustrations When pressin...

Page 11: ...NUTES TIME OUT DISPLAY SETTING 1 Press the ENTER button in DISY menu then enter to the two minutes time out display setting 2 Press the UP DOWN button to select ADDR BAT 3 Press the ENTER button to es...

Page 12: ...6 Then press the UP DOWN button to select RED SHUT TIME WAIT USE 7 Press the UP DOWN button to set up the parameter which are needed 8 Press the ENTER button to escape and save Illustrations When USE...

Page 13: ...OWN button to select YES 3 Press the ENTER button to confirm sending Illustrations 1 Please disconnect the connection of projector and DMX console before sending the parameter 2 The information of ADD...

Page 14: ...defined function is not available 7 Notice compatible Sweden DMX mode in this lights has complete data for sending and receiving but transmit function is not available here 8 IFRARED KEYBOARD OPERATI...

Page 15: ...l pin 3 positive signal Noted In order to avoid failures and interference signal transmission we connect a resistance120 1 4W at the end of the DMX connecting as below Termination reduces signal error...

Page 16: ...on is connected correctly or not It means having signal if it shows twinkling of the decimal point which in the lower right corner of the screen when exiting the screen saver Please check the DMX addr...