http://prolux.net.ua
16
Not Used
Do Not Use
11 CONNECTING PICTURE
12 TROUBLE SHOOTING
Problem
Reason and action
The lighting can’t be
started normally
Check the power connection is correct or not.
Please detect the voltage.
Power supply is damaged or incorrect connected. Call a
qualified personnel to fix it.
Connection of control board is not correct. Call a qualified
personnel to fix it.
Out of console’s
control
Please check the DMX connector and the power connection
is connected correctly or not. It means having signal if it
shows twinkling of the decimal point which in the lower right
corner of the screen when exiting the screen saver.
Please check the DMX address setting of lighting is correct
or not.
Check
【
CHMD
】
setting is correct or not.
Please check whether the DMX line is near to the high
voltage wire or not. In that case, it will damage or interfere
the DMX electric circuit.
The beam appears
dim, the brightness
declines obviously
Check whether the
【
CAL
】
is started or not and the set
value is too small.
Check whether the
【
POW
】
is in over temperature
protection situation or not, if yes, please take measures for
ventilation.