IV.
General
Maintenance
A.
Changing
the
Cartridge
•
Unlatch
and
open
the
door
to
access
the
cartridge
:
The
door
should
be
opened
only
to
perform
a
cartridge
or
programming
change.
When
in
use,
the
door
must
be
closed.
1.
Remove
air
nozzle
(located
on
the
side
of
the
cartridge
head)
by
rotating
90
degrees
and
pulling
towards
you.
(See
Picture
#
1)
2.
Detach
Injector
hose
and
hose
connector
from
the
cartridge
output
port
(located
on
the
top
of
the
cartridge
head).
This
is
done
by
unscrewing
the
hose
connector
from
the
cartridge
output
port
and
pulling
out.
3.
Remove
cartridge
from
appliance
enclosure.
4.
Install
new
cartridge,
place
and
tighten
hose
connector
firmly
on
cartridge
output
port.
5.
Insert
air
nozzle
and
rotate
the
handle
90
degrees
until
secured
(by
stem
retaining
tab
on
cartridge
head).
(See
Picture
#2)
6.
Turn
appliance
on.
Verify
that
the
plume
is
not
escaping
inside
the
appliance
and
that
all
connections
are
tight.
Close
the
door
when
complete.
B.
O
‐
ring
Replacement
–
every
6
months
or
as
needed:
•
Replace
the
air
nozzle
3
o
‐
rings
(Part
number
10208)
if
wore
down
or
swollen.
A
partially
full
cartridge
may
indicate
an
air
leak
between
the
air
nozzle
and
the
cartridge,
reducing
plume
output.
Replace
as
needed
and/or
every
six
months
for
preventative
maintenance.
•
If
there
is
any
Agent
that
leaks
during
the
cartridge
installation,
clean
it
carefully
with
a
paper
towel
with
some
ethanol
or
another
alcohol.
C.
Air
Filter
–
every
6
months
or
as
needed.
•
Replace
air
filter
(part
number
10417)
if
dirty.
If
any
dust
has
gathered
inside
the
unit,
remove
it
with
a
damp
paper
towel.
Picture
1
Picture
2
Cartridge
Retaining
Tab