Prolitec Air-Q 1100 User Manual Download Page 18

Air-Q 1100 User Guide

 

Page

 

16

 

of

 

18

 

 

 

(rev 1.0 5/13/09)

 

 

 

© Copyright 2009 Prolitec Inc 

The

 

O

Rings

 

on

 

the

 

stem

 

that

 

fits

 

into

 

the

 

head

 

may

 

be

 

worn

 

out

 

and

 

causing

 

an

 

air

 

leak

  

Replace

 

the

 

O

Rings

 

by

 

removing

 

the

 

worn

 

one

 

with

 

a

 

pointy

 

tool

 

and

 

rolling

 

on

 

the

 

new

 

ones

 

 

You

 

detect

 

the

 

fragrance

 

when

 

entering

 

the

 

room

 

but

 

after

 

a

 

while

 

you

 

no

 

longer

 

notice

 

it.

  

This

 

is

 

called

 

olfactory

 

adaptation

 

and

 

is

 

normal.

  

Leave

 

the

 

area

 

for

 

5

 

to

 

10

 

minutes.

 

Come

 

back

 

inside,

 

you

 

will

 

smell

 

the

 

fragrance

 

once

 

again.

 

Do

 

not

 

hesitate

 

to

 

repeat

 

this

 

process

 

every

 

time

 

that

 

you

 

doubt

 

the

 

presence

 

of

 

the

 

fragrance

 

in

 

the

 

area.

 

Summary of Contents for Air-Q 1100

Page 1: ...Page 1 of 18 Air Q 1100 User Guide Rev 1 0 5 13 09 2009 Prolitec Inc...

Page 2: ...utions B Fragrance Precautions III Appliance and Controls 4 IV General Maintenance 5 A Changing the Cartridge B O ring replacement C Battery Replacement V Commissioning Air Q 1100 7 A Unit Programming...

Page 3: ...1100 applications include air treatment for odor remediation scent branding and ambient scenting in public spaces such as casinos malls hotels theaters ballrooms convention centers hospitals and restr...

Page 4: ...osol droplet The Air Q droplet is 1 1 000 000th the weight of an aerosol droplet This means the droplets behave as if they were dry do not leave any residue on the blades or interior duct surfaces and...

Page 5: ...wer the appliance Unplug before cleaning B Air Q Cartridge Precautions Read the Product Safety Information Sheet and the Material Safety Data Sheet enclosed provided with each shipment of Cartridges I...

Page 6: ...f 18 rev 1 0 5 13 09 Copyright 2009 Prolitec Inc III Appliance and Controls Air Q 1100 Cartridge Injector Hose Control Display Control Buttons Power Cord Program Selector Battery Tab Air Nozzle Hose C...

Page 7: ...ge output port 5 Insert air nozzle and rotate the handle 90 degrees until secured by stem retaining tab on cartridge head See Picture 2 6 Turn appliance on Verify that the plume is not escaping inside...

Page 8: ...e door to access the enclosure 2 Using a pair of tweezers or needle nose pliers remove battery from the center opening of the oval grommet The grommet is located on the front of the blue bracket below...

Page 9: ...er right side of the time digits Hold to fast forward 4 Using the 24 7 Mode If you want the Air Q 1100 to run continuously 7 days a week 24 hours a day turn the dial to 24 7 If not skip to Step 5 5 Se...

Page 10: ...0 91 000 1 900 2 600 26 thru 30 91 000 117 000 2 600 3 300 31 thru 35 117 000 146 000 3 300 4 100 36 thru 40 146 000 177 000 4 100 5 000 41thru 45 177 000 214 000 5 000 6 000 46 thru 50 214 000 250 00...

Page 11: ...ion for placement of the appliance See section C Appliance Positioning 6 Note the distance between the insertion point and the proposed appliance location NEVER MORE THAN 6 FEET and there should NEVER...

Page 12: ...Guide Page 10 of 18 rev 1 0 5 13 09 Copyright 2009 Prolitec Inc Optional One hose quick disconnect fitting with 3 feet hose extension with hose clamps to increase distance up to 6 feet see note 6 abo...

Page 13: ...hilled water and DX coils Open gas flames should absolutely be avoided If installation must be over gas heated coils or open gas flames contact Prolitec Technical Support The best location for the App...

Page 14: ...ct to a nearby outlet 4 Open the enclosure door and unscrew the aluminum cap of the waterproof collar located on top of the appliance enclosure Remove and set aside the grommet see photo on Page 13 5...

Page 15: ...inside of the grommet if needed to allow the Injector hose to easily slide through Leave approximately 2 inches of hose length inside the appliance to provide enough play when replacing the cartridge...

Page 16: ...in a straight section of duct and far away from any turns branches or cross section changes as practical and not immediately after the supply fan 1 At the insertion point drill a hole using a drill bi...

Page 17: ...ith a pointy tool and rolling on the new ones Fragrance intensity is stronger than just detectable The output rate is too high Lower the output rate in increments of one or two settings or down to the...

Page 18: ...the worn one with a pointy tool and rolling on the new ones You detect the fragrance when entering the room but after a while you no longer notice it This is called olfactory adaptation and is normal...

Page 19: ...tions must be outside these ranges contact Prolitec Safety and Support Hotline at 888 615 9282 Do not drop Air Q 1100 on the floor Do not drop it in or position it near an open basin of water Do not p...

Page 20: ...Frequency 50 60 Hz Protection Switching power supply Internal Power 12 VDC at 1 5 A Back up battery Lithium 3V CR2032 Performance Up to 250 000 cu feet 7 080 cu meters subject to air flow conditions C...

Reviews: