Beta Draft Confidential
Installing and Wiring the Thermostat
Proliphix Internet Managed Thermostat (IMT) 350c/350w Installation Guide, Release 1.0
9
Part No. 600-03000-350, Rev. 1
To wire the base plate terminals:
1
Use
Table 2 on page 6
to match the letter of your existing thermostat wire to the
corresponding terminal letter on the Proliphix base plate.
2
Strip the wire insulation from the wire ends. Verify that the wire ends are straight. To
avoid damaging the labels, use caution when handling the wires and push any excess
wire back into the wall.
3
Using
Figure 1 on page 7
or
Figure 2 on page 8
as a guide, connect the labeled wires
to the terminal post with the corresponding letter on the IMT base plate. For example,
connect the wire labeled “W1” to the W1 terminal post.
4
Loosen the terminal post screw used to secure the wires. Insert the wire straight down
into the square hole and secure the corresponding screw to the wire.
5
Verify that the wire is securely attached to the terminal post in the base plate by gently
tugging on the wire.
Configuring Remote Sensors
The Proliphix thermostats provide two remote (external) sensor ports. The IMT
supports Thermistor and contact closure sensing. (Go to www.proliphix.com for a
complete list of supported sensors.) You must configure the two switches for each
sensor to match the sensor category. See
Figure 3
and
Table 3 on page 10
.
Figure 3
shows and example of the remote sensor switch settings.
Figure 3 Remote Sensor Switch Settings - Base Plate Label