Proline Prosonic Flow 93W Technical Information Download Page 1

TI00084D/06/EN/13.11
71136723

Technical Information

Proline Prosonic Flow 93W

Ultrasonic flow measuring system
Volume flow measurement for standard applications 
with drinking water, wastewater and process water

Applications

The sensors are perfectly suited for the non-contact
measurement of pure or slightly contaminated liquids, 
regardless of the pressure or electrical conductivity.

• Suitable for pipe diameters up to DN 15 to 4000 

(

½

 to 160")

• Can be used with all metal and plastic pipes lined or 

unlined and with composite pipes

• Ideal solution for applications with water, e.g. drinking 

water, industrial water, wastewater, saltwater, 
deionized water, cooling water and heating water

• Perfectly suitable for

– retrofit measurement
– flow monitoring
– improving measuring points

• Interface for easy integration into all common 

distributed control systems:
– HART
– PROFIBUS  DP/PA
– FOUNDATION Fieldbus

Features and benefits

The Prosonic Flow ultrasonic clamp-on system allows 
accurate and cost-effective flow measurement from 
outside the pipe and without the need to interrupt the 
process. The flow measurement is bidirectional and 
causes no pressure loss.

• Easy, safe and menu-guided sensor mounting ensures 

precise measuring results

• Long-term system integrity thanks to robust sensor 

and industrial mounting kit design

• Automatic frequency scan for optimized installation 

and maximum measuring performance

• IP 68 for pipes under water
• Also available as insert version
• Can also be supplied as two-path system for short 

inlet runs

• Remote configuration using Hauser's 

FieldCare software

Summary of Contents for Prosonic Flow 93W

Page 1: ...ly suitable for retrofit measurement flow monitoring improving measuring points Interface for easy integration into all common distributed control systems HART PROFIBUS DP PA FOUNDATION Fieldbus Featu...

Page 2: ...bility 14 Operating conditions installation 14 Installation instructions 14 Inlet and outlet runs 15 Operating conditions environment 16 Ambient temperature range 16 Storage temperature 16 Degree of p...

Page 3: ...oss sectional area The measuring system calculates the volume flow of the fluid from the measured transit time difference and the pipe cross sectional area In addition to measuring the transit time di...

Page 4: ...n the table and you do not have the corresponding sound velocities for these fluids materials you can use the DDU18 and DDU19 sensors to determine the values Prosonic Flow 93 wall mount housing For mo...

Page 5: ...sensors are located on the same side of the pipe A0001108 Sensor mounting arrangement A Mounting arrangement for measurement via one traverse B Mounting arrangement for measurement via two traverses D...

Page 6: ...Type of Mounting 1 Prosonic Flow W DN 15 to 65 to 2 6 MHz W CL 6F 2 traverses 5 DN 50 to 65 2 to 2 2 MHz W CL 2F 2 or 1 traverses 2 DN 80 3 2 MHz W CL 2F 2 traverses DN 100 to 300 4 to 12 2 MHz or 1...

Page 7: ...e Averaging function generally provides you with a more stable measured value The function is thus suitable for measurements under conditions that are not ideal e g short inlet runs The two measuring...

Page 8: ...ctor 30 V DC 250 mA Time constant selectable 0 05 to 100 s Frequency output End frequency 2 to 10000 Hz fmax 12500 Hz On off ratio 1 1 pulse width max 10 s Pulse output Pulse value and pulse polarity...

Page 9: ...A Error current FDE fault disconnection electronic 0 mA Signal encoding Manchester II Function blocks 8 Analog Input AI 1 Discrete Output 1 PID Output data volume flow channel 1 or channel 2 sound vel...

Page 10: ...o 26 DP B PA FF with polarity protection Terminal No 27 DP A PA FF with polarity protection e Ground terminal for signal cable shield Fieldbus cable f Service adapter for connecting service interface...

Page 11: ...t output HART 93 B Relay output 2 Relay output 1 Frequency output Current output HART 93 H PROFIBUS PA 93 J PROFIBUS DP 93 K FOUNDATION Fieldbus Flexible communication boards 93 C Relay output 2 Relay...

Page 12: ...4 mm 2 0 16 Cable gland M20 1 5 Thread for cable entry NPT G A0008152 Cable gland for two connecting cables per cable entry Connecting cable sensor transmitter Only use the connecting cables supplied...

Page 13: ...or at the measuring point 0 5 o r 3 mm s 1 5 o r 2 o r 3 mm s Measured error at the measuring point The measured error at the measuring point is made up of the measured error of the device 0 5 o r and...

Page 14: ...l the sensors in a riser Note Entrained air or gas bubbles in the measuring tube can result in an increase in measuring errors For this reason avoid the following mounting locations Highest point of a...

Page 15: ...installation range max 120 Inlet and outlet runs If possible install the sensor well clear of fittings such as valves T pieces elbows etc Compliance with the following inlet and outlet runs is require...

Page 16: ...te It is permitted to insulate the sensors mounted on the pipe Mount the transmitter in a shady location and avoid direct sunlight particularly in warm climatic regions Storage temperature The storage...

Page 17: ...ement Standard 40 to 80 C 40 to 176 F Optional 0 to 170 C 32 to 338 F DDU19 sensor accessories wall thickness measurement 20 to 60 C 4 to 140 F Medium pressure range nominal pressure No pressure limit...

Page 18: ...0 81 53 L M N O P Q R S T 1 95 53 102 81 5 11 5 192 8 M5 20 2 6 5 1 Securing screw for wall mounting M6 screw head max 10 5 mm All dimensions in mm A B C D E F G H J K 8 46 9 84 3 56 6 27 5 31 3 54 1...

Page 19: ...aid mounting mounting kits are available as accessories 28 A0001131 Pipe mounting Note To aid mounting mounting kits are available as accessories 28 A0001132 245 9 65 110 4 33 210 8 27 0 5 0 019 0 5...

Page 20: ...Hauser Prosonic Flow W sensor DN 15 to 65 to 2 A0011502 Dimensions in SI units Dimensions in US units B A C E F D A B C D E F 72 331 39 28 233 450 All dimensions in mm A B C D E F 2 83 13 03 1 541 1...

Page 21: ...0 5 H I Depends on the measuring point conditions pipe fluid etc Dimension H can be determined Via transmitter programming Quick Setup or FieldCare Online Applicator Pipe outer diameter All dimension...

Page 22: ...ring point conditions pipe fluid etc Dimension G can be determined Via transmitter programming Quick Setup or FieldCare Online Applicator Pipe outer diameter All dimensions in mm A B C D E F 2 20 2 44...

Page 23: ...suring point conditions pipe fluid etc Dimensions F and G can be determined Via transmitter programming Quick Setup or FieldCare Online Applicator All dimensions in mm A B C D E F G 2 28 5 91 2 56 25...

Page 24: ...e fluid etc Dimensions F G and H can be determined Via transmitter programming Quick Setup or FieldCare Online Applicator All dimensions in mm A B C D E F G H 2 28 5 91 3 15 25 Pipe outer diameter Sen...

Page 25: ...cket textile or stainless steel 1 4301 304 Sensor contact surfaces chemically stable plastic Prosonic Flow W insertion version Sensor holder stainless steel 1 4301 Sensor housing stainless steel 1 430...

Page 26: ...k Setup menus for straightforward commissioning Language group Language groups available for operation in different countries Western Europe and America WEA English German Spanish Italian French Dutch...

Page 27: ...ATION Fieldbus H1 Interoperability Test Kit ITK revision status 5 01 device certification number on request The device can also be operated with certified devices of other manufacturers Physical Layer...

Page 28: ...ppropriate plug in point modules for converting the current input output configuration to a new version DK9UI Sensor W DN 15 to 4000 to 160 Clamp on version DN 15 to 65 to 2 20 to 80 C 4 to 176 F 6 0...

Page 29: ...nic Flow W DN 15 to 65 to 2 Conduit adapter incl cable entry M20 1 5 Conduit adapter incl cable entry NPT Conduit adapter incl cable entry G Prosonic Flow W DN 50 to 4000 2 to 160 Conduit adapter incl...

Page 30: ...browser and or WAP cellular phone Limit value monitoring with alarm signaling via e mail or SMS Synchronized time stamping of all measured values Remote diagnosis and remote configuration of connected...

Page 31: ...ieldbus BA078D and BA079D Supplementary documentation on Ex ratings ATEX FM CSA IECEx NEPSI Registered trademarks HART Registered trademark of HART Communication Foundation Austin USA PROFIBUS Registe...