29
Z700SPOT
4.
2
REPLACEMENT OF THE GOBOS
The rotating gobos can be replaced and e. g. be exchanged for individual gobos.
1. Disconnect the main plug from the socket and let the unit cool down for 20 minutes.
2. Release the screws and remove the upper part of the housing of the pan head.
3. Turn the gobo wheel as indicated in fig. 9 in such a way that the gobo to be replaced is on top.
4. Push the gobo plate follow the direction A, and pull out the plate follow the direction B.
5. Move the ring over the gobo away, so you can take out the gobo.
6. Never release the screws on the gobo support; they keep the ball bearing together!
7. Insert the new gobo into the gobo support and fasten it with the retaining ring. If the gobo has a side
which is darker or more matt, this side must be directed towards the lamp.
8. Make sure the gobo plate is installed under the pressure plate (C).
9. Replace the housing of the pan head and retighten the screws.
Fig.10
Ring
Fig.9
Pressure plate
B
A
(C)