background image

PROLIGHTS - StudioCob  

PFC2

09

7 - DMX CONNECTION 

CONNECTION OF THE CONTROL SIGNAL: DMX LINE

The product has XLR sockets for DMX input and output.

The default pin-out on both socket is as the following diagram:

Fig. 04

Pin1 : GND - Shield

Pin2 : - Signal

Pin3 : + Signal

Pin4 : N/C

Pin5 : N/C

DMX - OUTPUT

XLR socket

DMX - INPUT

XLR plug

INSTRUCTIONS FOR A RELIABLE DMX CONNECTION

Use shielded twisted-pair cable designed for RS-485 devices: standard microphone cable cannot trans-

mit control data reliably over long runs. 24 AWG cable is suitable for runs up to 300 meters (1000 ft). 

Heavier gauge cable and/or an amplifier is recommended for longer runs.

To split the data link into branches, use splitter-amplifiers in the connection line.

Do not overload the link. Up to 32 devices may be connected on a serial link.

CONNECTION DAISY CHAIN

Connect the DMX data output from the DMX source to the product DMX input (male connector XLR) 

socket.

Run the data link from the product XLR output (female connector XLR) socket to the DMX input of the 

next fixture.

Terminate the data link by connecting a 120 Ohm signal termination. If a splitter is used, terminate 

each branch of the link.

Install a DMX termination plug on the last fixture on the link.

CONNECTION OF THE DMX LINE

DMX connection employs standard XLR connectors. Use shielded pair-twisted cables with 120Ω im-

pedance and low capacity.

The following diagram shows the connection mode:

Fig. 05 - Example 10 DMX channels configuration

.  .  .  .  .  .  .  .  .  .  .  .  

DMX Address: 33

DMX Address: 63

DMX Address: 43

DMX Address: 53

.  .  .  .  .  .  .  .  .  .  .  .  

DMX512 Controller

DMX IN

DMX IN

DMX IN

DMX IN

DMX OUT

DMX OUT

DMX OUT

DMX OUT

Summary of Contents for StudioCob PFC2

Page 1: ...USER MANUAL English version StudioCob PFC2 150W IP65 rated full colour COB LED Par REV 01 09 21...

Page 2: ...conomic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this document Product user manual can be downloaded from the website www prolights...

Page 3: ...LINE 09 INSTRUCTIONS FOR A RELIABLE DMX CONNECTION 09 CONNECTION DAISY CHAIN 09 CONNECTION OF THE DMX LINE 09 CONSTRUCTION OF THE DMX TERMINATION 10 DMX ADDRESSING 10 8 CONTROL PANEL 11 DISPLAY AND B...

Page 4: ...ments of all connected devices Isolate the fixture from power immediately if the power plug or any seal cover cable or other components are damaged defective deformed or showing signs of overheating D...

Page 5: ...ace of the fixture can reach up to 60 C 140 F during operation Avoid contact with people and materials Maintenance Warning Disconnect the fixture from AC mains power and allow to cool for at least 10...

Page 6: ...electrical equipment supplied at low voltage LVD 2014 30 EU Electromagnetic Compatibility EMC 2011 65 EU Restriction of the use of certain hazardous substances RoHS Other approvals The product meets...

Page 7: ...ocket L 3m C6002 slim aluminium clamp 200 kg loading 48 51 mm tubes M10 bolt RSR0630A B steel security cable for hanging bodies inox steel shackle L 60 cm silver black STUDIOCOBPLUSL18 optics for STUD...

Page 8: ...imary attachments by attaching a safety wire that is approved as a safety attachment for the weight of the fixture to an anchor point on the product main frame Do not use removable parts or weak ancho...

Page 9: ...er from the product disconnect the Mains from the socket 4 CONNECTION TO THE MAINS SUPPLY WARNING For protection from electric shock the fixture must be earthed The product is equipped with auto switc...

Page 10: ...t 4 DMX IN 5 p XLR 1 GND 2 sign 3 sign 4 N C 5 N C 5 POWER IN for connection to the Mains 100 240V 50 60Hz 6 USER INTERFACE with display and buttons for access to the control panel functions 7 DMX OUT...

Page 11: ...e connection line Do not overload the link Up to 32 devices may be connected on a serial link CONNECTION DAISY CHAIN Connect the DMX data output from the DMX source to the product DMX input male conne...

Page 12: ...be executing the same behaviour Selecting the same address to multiple fixtures can be useful for diagnostic purposes and symmetrical control DMX addressing is limited to make it impossible to set the...

Page 13: ...r access to the control panel functions MENU used to access the menu tree or to return a previous menu window UP browse upwards through the menu list and increases the numeric value displayed DOWN bro...

Page 14: ...0 255 4 Auto Show Auto 1 Auto 2 Auto 3 Auto 4 Auto 5 Speed 0 100 Speed 0 100 Speed 0 100 Speed 0 100 Speed 0 100 5 Master Slave Master Slave Allow you to link and operating in synk multiple units wit...

Page 15: ...ctive 11 Key Lock On Of Allows you lock the buttons on the control panel by a password Press following com binations password in order to access to the user menu UP DOWN UP DOWN ENTER 12 Information F...

Page 16: ...1 x x Power Lamp Settings DEVICE_HOURS 0x0400 x x LAMP_HOURS 0x0401 x x LAMP_STRIKES 0x0402 x x Display Settings DISPLAY_INVERT 0x0500 x x Control IDENTIFY_DEVICE 0x1000 x x 10 RDM FUNCTIONS The produ...

Page 17: ...h 4 Ch 6 Ch 10 Ch 1 RED DIMMER DIMMER 2 GREEN RED RED 3 BLUE GREEN GREEN 4 WHITE BLUE BLUE 5 WHITE WHITE 6 STROBE STROBE 7 COLOR FUNCTION 8 COLOR PRESETS WHITE PRESETS COLOR MACRO 9 COLOR MACRO SPEED...

Page 18: ...100 100 RGB 0 100 0 100 RGB 100 0 0 100 RGB 100 0 100 0 100 RGB 0 100 0 100 100 RGBW 100 100 100 100 WHITE PRESETS active when Color function is on White presets RGBW 2000K 3000K RGBW 3000K 4000K RGBW...

Page 19: ...er using the four screws to the four holes on the front cover of the unit 2 C A B DETAIL Push the pin A and open upward the gel frame lock B Insert the filter frame C from above into the guides DETAIL...

Page 20: ...ur holes on the front cover of the unit 2 C A B DETAIL Push the pin A and open upward the frame lock gel B Insert the barn doors C into from above by inserting the linking holders into the guides DETA...

Page 21: ...A washer B front cover C glass lens D filter E Insert the optic by replacing the one already present and follow the reverse procedure to reassemble the parts NOTE To remove the accessory reverse the p...

Page 22: ...other service operations on the product must be carried out by PROLIGHTS its approved service agents or trained and qualified personnel It is PROLIGHTS policy to apply the strictest possible calibrat...

Page 23: ...ctors and connect them directly together to bypass one product at a time until normal operation is regained Once found the error have that fixture serviced by a qualified technician Timeout error afte...

Page 24: ...Note...

Page 25: ...Note...

Page 26: ...Note...

Page 27: ......

Page 28: ...PROLIGHTS is a trademark of MUSIC LIGHTS S r l musiclights it prolights it support prolights it Via A Olivetti snc 04026 Minturno LT ITALY Tel 39 0771 72190...

Reviews: