background image

ERRORS

ERROR SHOWED ON SCREEN

POSSIBLE CAUSES 

CODE ERROR

[DMX ACTIVE]

DMX Signal is present when using TRANSFER 

CONFIG function

1

[TEMPERATURE ERROR]

TEMPERATURE is out of standard 

temperature range use (minus or plus) 

2

[BATTERY ERROR]

Recharge the main battery, keeping the 

product under charge for some hours. 

3

If the error still occurrs, the battery is faulty . 

Replace the battery.

4

[NO BATTERY]

Battery not detected. It may be faulty or 

disconnected.

5

[LOW BATTERY]

Battery is almost empty (20%). Need to 

recharge 

6

[BATTERY CHARGER ERROR]

Battery charger circuit not working

7

13 - ERROR MESSAGES

The error is shown on the unit display. In the table below, the "ERROR SHOWED ON SCREEN" column 

lists the possible errors, accompanied by a possible cause ("POSSIBLE" CAUSES "column) and a code 

error.

PROLIGHTS - SmartBat 

Wash

32

Summary of Contents for SmartBat Wash

Page 1: ...USER MANUAL REV 01 10 22 English version SmartBat Wash 15x20W LED Wash Light IP65 rated with an RGB Warm White LED source wirelessly controlled with battery or wired with mains power...

Page 2: ...onomic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this document Product user manual can be downloaded from the website www prolights i...

Page 3: ...1 CONNECTION OF THE DMX LINE 11 CONSTRUCTION OF THE DMX TERMINATION 12 DMX ADDRESSING 12 OPERATION AS A WIRELESS TRANSMITTER 12 IN TO WDMX 13 OPERATION AS A WIRELESS RECEIVER 13 WDMX TO DMX RX 13 8 CO...

Page 4: ...batteries that do not complete full charge cycles the life expectancy can be less than two years also Rechargeable Lithium Ion batteries have a limited life and will gradually lose their capacity to h...

Page 5: ...en 5 C and 20 C 41 F and 68 F Handling Precautions Do not disassemble crush or puncture a battery Do not short the external contacts on a battery Do not dispose of a battery in fire or water Do not ex...

Page 6: ...formed or showing signs of overheating Do not reapply power until repairs have been completed Refer any service operation not described in this manual to PROLIGHTS Service team or an authorized PROLIG...

Page 7: ...utes before handling Only technicians who are authorized by PROLIGHTS or Authorised service partners are permitted to open the fixture Users may carry out external cleaning following the warnings and...

Page 8: ...s 2 FCC Compliance This device complies with Part 15 of the FCC Rules Operation is subject to the fol lowing two conditions 5 This device may not cause harmful interference and 6 This device must acce...

Page 9: ...WASH PRL IRC RGBWA IR controller 29 buttons manual static colours auto programs fade C6002A B slim aluminium clamp 200 kg loading 48 51 mm tubes M10 bolt silver black RSR0630A B steel security cable f...

Page 10: ...primary attachments by attaching a safety wire that is approved as a safety attachment for the weight of the fixture to an anchor point on the product main frame Do not use removable parts or weak an...

Page 11: ...er from the product disconnect the Mains from the socket 4 CONNECTION TO THE MAINS SUPPLY WARNING For protection from electric shock the fixture must be earthed The product is equipped with auto switc...

Page 12: ...on to the Mains 100 240V 50 60Hz 7 POWER OUT power output for connection of multiple units in series 8 BUTTON to turn on ff the unit 9 HOLES to attach Quick lock 10 USER INTERFACE with display and but...

Page 13: ...connection line Do not overload the link Up to 32 devices may be connected on a serial link CONNECTION DAISY CHAIN Connect the DMX data output from the DMX source to the product DMX input male connec...

Page 14: ...Press Menu to exit and return to the Home screen OPERATION AS A WIRELESS TRANSMITTER SMARTBATWASH can be used as wireless transmitter to transmit DMX signal to different wireless re ceivers To use SMA...

Page 15: ...CT on display then press ENTER button to confirm 2 Use UP DOWN buttons for select Wireless then press ENTER to confirm 3 Push ENTER button on WDMX ON OFF function and enable it to ON 4 Select WDMX mod...

Page 16: ...play and buttons for access to the control panel functions Used to access the menu tree or to return a previous menu window Browse upwards through the menu list and increases the numeric value display...

Page 17: ...scription 1 CONNECT DMX ADDRESS 1 512 Set DMX Address DMX MODE FIXTURE UNO FIXED COLORS R Set DMX Mode G B W RG RB RW GB GW BW RGB RGW RBW GBW RGBW COLOR MACRO See Color Macro page WHITE PRESETS 2700K...

Page 18: ...the retransmis sion of the DMX from the receiv er to the other units connected by cable to the receiver itself OFF 2 SETUP SCREEN BACKLIGHT ON Select the timing after that dis play will switch automa...

Page 19: ...Define the behaviour of fixture in case of AC DC signal presence AC Mode has priority over DMX Fault BLACKOUT BATTERY RECHARGE AUTO AUTO Fixture will charge im mediately in case of no signal at startu...

Page 20: ...is used to individu ally STROBE the selected color HOLD TIME defines how long the color is hold on the output FADE IN OUT TIME defines the timings of fading in out The effects can be considered as CH...

Page 21: ...menu MENU ENTER then power on CLEAR ALL Clear all the infor reset counter and set all to default value PROLIGHTS SmartBat Wash 19 WHITE PRESETS 2700K DIMMER 000 255 HUE 025 025 2800K 3200K 3500K 4000K...

Page 22: ...mation 0x0060 x N A PRODUCT_DETAIL_ID_LIST Product Information 0x0070 x N A DEVICE_MODEL_DESCRIPTION Product Information 0x0080 x N A x MANUFACTURER_LABEL Product Information 0x0081 x N A DEVICE_LABEL...

Page 23: ..._STATE Power Lamp Settings 0x0403 x x N A LAMP_ON_MODE Power Lamp Settings 0x0404 x x N A DEVICE_POWER_CYCLES Power Lamp Settings 0x0405 x x N A DISPLAY_INVERT Display Settings 0x0500 x x N A DISPLAY_...

Page 24: ...LUE Manufacturer PIDs x x 0 255 Refer to menu section MANUAL WHITE Manufacturer PIDs x x 0 255 Refer to menu section FX Manufacturer PIDs x x 0 4 Refer to menu section WH CAL 0 OFF 1 STUDIO 2 MANUAL 3...

Page 25: ...Address GET SET Value Description Default Value CURRENT HOURS Manufacturer PIDs x MAINTENANCE TIME ALERT PERIOD Manufacturer PIDs x x MAINTENANCE TIME ELAPSED TIME Manufacturer PIDs x x WIRELESS QUAL...

Page 26: ...DM Model ID 0xD097 MODE PARAMETER UNO DUO BASIC STANDARD EXTENDED DIMMER 1 1 1 1 1 DIMMER FINE 2 2 2 STROBE 3 3 CCT 4 4 TINT 5 CROSSFADE 5 6 RED 2 7 RED FINE 8 GREEN 3 9 GREEN FINE 10 BLUE 4 11 BLUE F...

Page 27: ...Fast 2 62 Open 63 64 Pulse In from slow to fast 65 125 Open 126 127 Pulse Out from slow to fast 128 188 Open 189 190 Random from slow to fast 191 251 Open 252 255 Dimmer Function 8 bit value 16 bit v...

Page 28: ...00 78 81 20025 20935 5100 5200 81 85 20935 21845 5200 5300 85 89 21845 22755 5300 5400 89 92 22755 23665 5400 5500 92 96 23665 24576 5500 5600 96 99 24576 25486 5600 5700 99 103 25486 26396 5700 5800...

Page 29: ...4 60984 9500 9600 237 241 60984 61894 9600 9700 241 244 61894 62804 9700 9800 244 248 62804 63715 9800 9900 248 251 63715 64625 9900 10000 251 255 64625 65535 Tint Function 8 bit value 16 bit value No...

Page 30: ...27 FLAME RED 28 29 BASTARD AMBER 30 31 DEEP ORANGE 32 33 PALE GOLD 34 35 APRICOT 36 37 BRIGHT BLUE 38 39 PRIMARY GREEN 40 41 SPECIAL LAVENDER 42 43 PALE LAVENDER 44 45 DEEP GOLDEN AMBER 46 47 MEDIUM...

Page 31: ...8 119 MEDIUM YELLOW 120 121 LEE MINUS GREEN 122 123 PALE GOLD 124 125 ORANGE 126 127 DEEP STRAW 128 129 ROSE PURPLE 130 131 DEEP PURPLE 132 133 SOFT GREEN 134 135 Reserved for future use 136 209 2700K...

Page 32: ...RATED 24 25 DIMMER CURVE LINEAR 26 27 DIMMER CURVE S CURVE 28 29 DIMMER CURVE SQUARE LAW 30 31 DIMMER CURVE INVERSE SQUARE LAW 32 33 DIMMER SPEED AUTO 34 35 DIMMER SPEED FAST 36 37 DIMMER SPEED MEDIUM...

Page 33: ...N 94 95 STAND ALONE MASTER DMX 96 97 STAND ALONE MASTER NO DMX 98 99 STAND ALONE SLAVE 100 101 STAND ALONE EFFECT 1 102 103 STAND ALONE EFFECT 2 104 105 STAND ALONE EFFECT 3 106 107 STAND ALONE EFFECT...

Page 34: ...ours 3 If the error still occurrs the battery is faulty Replace the battery 4 NO BATTERY Battery not detected It may be faulty or disconnected 5 LOW BATTERY Battery is almost empty 20 Need to recharge...

Page 35: ...FFUSION FILTER CODE SBWFILTER25 40 1060 OPTIONAL B A DETAIL Mount the accessory light diffusion filter A on the front cover B the hooking is magnetic due to the magnets on the frame of the accessory l...

Page 36: ...door A insert the two marked pin on down edge of the barn door B into the holes provided on the bottom edge of the unit head C 2 Then positioning the spring pin on the hardware into the hole provided...

Page 37: ...to the IPTESTBOX by inserting the quick connect fitting into the coupler 3 Insert the threaded end into the threaded valve hole socket For the operating procedure using the instrument refer to the IP...

Page 38: ...other service operations on the product must be carried out by PROLIGHTS its approved service agents or trained and qualified personnel It is PROLIGHTS policy to apply the strictest possible calibrati...

Page 39: ...tors and connect them directly together to bypass one product at a time until normal operation is regained Once found the error have that fixture serviced by a qualified technician Timeout error after...

Page 40: ...Note...

Page 41: ...Note...

Page 42: ...Note...

Page 43: ......

Page 44: ...PROLIGHTS is a trademark of MUSIC LIGHTS S r l musiclights it prolights it support prolights it Via A Olivetti snc 04026 Minturno LT ITALY Tel 39 0771 72190...