7
GHOST GH100F
Refer to the table below to access and settings:
BUTTON
INSTRUCTIONS
FUNCTION
Can be select the desired function:
[INTERVAL SET]
,
[DURATION SET], [TIMER OUT], [VOLUME
OUT], [DMX512], [LOW>HI] e [HEATER & FAN OPEN].
•
[INTERVAL SET] -
Setting of interval time from 1-200 seconds, with the button UP/DOWN,
effective when starting the TIMER mode.
•
[DURATION SET] -
Setting of duration time from 1-200 seconds, with the button UP/DOWN,
effective when starting the TIMER mode.
•
[TIMER OUT] -
Setting the amount of emission from 1% - 100% with the button UP/DOWN, for
TIMER mode.
•
[VOLUME OUT] -
Setting the amount of the volume of emission from 1%-100%, with the
button UP/DOWN, effective when starting the VOLUME mode.
•
[DMX 512] -
Setting of DMX address, their the numerical values change by using the UP/DOWN
buttons.
•
[LOW>HI] -
Select the fan speed with the button UP/DOWN.
•
[HEATER & FAN OPEN] -
This function allows to activate or disable the fan and heater. Using the
MANUAL buttons to switch the fan and the heater on or off.
UP
Button for increasing numerical value
DOWN
Button for decreasing numerical value
TIMER
Pushing this button, the machine will work according to the set up interval time, duration and
adjusted volume.
VOLUME
Pushing this button, the unit will issue the volume in accord with VOLUME OUT.
MANUAL
Pushing this button, the unit will issue its maximum volume. When the button is released the unit
will return to its original state. This function can be executed under any circumstances.
2.3 TIMER MODE
When the LCD panel display “READY TO FAZER”, push the TIMER button will enable the user to initiate
preset up preferred timer mode. Machine will work according to the set up interval time, and amount to
deliver the most satisfactory fog. The unit counts down to 0 seconds and emits fog.
To deactivate the timer mode, press the button TIMER again
2.4 VOLUME MODE
When the LCD panel display “READY TO FAZER”, push VOLUME button , to activate continuos fog output.
The display indicates VOLUME followed by the value that was set in menu item VOLUME OUT or NON STOP
BURST when maximum fog volume was selected. To stop the fog output, press the button VOLUME once
again.