3 - INSTALLATION
MOUNTING
Check that the supporting structure can safely bear the weight of all installed fixtures, clamps, cables,
auxiliary equipment, etc. and complies with locally applicable regulations.
When suspending the fixture above ground level, secure it against failure of primary attachments by
attaching a safety wire that is approved as a safety attachment for the weight of the fixture to an anchor
point on the product main frame.
Do not use removable parts or weak anchors for secondary attachment.
Warning! When clamping the fixture to a truss or other structure at any angle, use clamps of half-cou-
pler type. Do not use any type of clamp that does not completely encircle the structure when fastened.
RSR0630A/B
steel security cable
C6002
clamp
RSR0630A/B
steel security cable
C6040
clamp
RSR0630A/B
steel security cable
C6040
clamp
Ø10.5 mm
Ø0.41 in