3
PROLIGHTS - Ecl
PanelTWCJR
Minimun
distance
Risk
Group 2
Risk
Group 1
0.2 m
0.7 ft
14 m
47.93 ft
Protection and Warning against electrical shock
• Do not remove any cover from the product and disconnect the product from AC
power before servicing.
•
Ensure that the fixture is electrically connected to ground (earth). And use only a
source of AC power that complies with local building and electrical codes and has
both overload and ground-fault (earth-fault) protection.
•
Before using the fixture, check that all power distribution equipment and cables are
in perfect condition and rated for the current requirements of all connected devices.
•
Isolate the fixture from power immediately if the power plug or any seal, cover, cable,
or other component is damaged, defective, deformed or showing signs of overheat-
ing. Do not reapply power until repairs have been completed.
• Refer any service operation not described in this manual to PROLIGHTS Service team
or an authorized PROLIGHTS service center.
Connection to mains supply
•
The Connection to the mains supply must be carried out by a qualified electrical
installer.
•
Use only AC supplies 100-240V 50-60Hz, the fixture must be electrically connected
to ground (earth).
• Select the cable cross section in according with the maximum current draw of the
product and the possible number of products connected at the same power line.
• The AC mains power distribution circuit must be equipped with mresidual
current circuit breaker protection.
• Do not connect it to a dimmer system; doing so may damage the product.
T 70°C
c
Temperature of the external surface
•
The surface of the fixture can reach up to 70 °C (159.8 °F) during operation. Avoid
contact with people and materials.
Maintenance
•
Warning! Disconnect the fixture from AC mains power and allow to cool for at least
10 minutes before handling.
•
Only technicians who are authorized by PROLIGHTS or Authorised service partners
are permitted to open the fixture.
•
Users may carry out external cleaning, following the warnings and instructions pro
-
vided, but any service operation not described in this manual must be referred to a
qualified service technician.
•
Important! Excessive dust, smoke fluid, and particle build up degrades performance,
causes overheating and will damage the fixture. Damages caused by inadequate
cleaning or maintenance is not covered by the product warranty.
Photobiological safety
•
This device emits potentially dangerous optical radiation and is identified in the cat
-
egory of Risk Group 2 according to EN 62471.