4D
¥
Weight
:
2.5KG (Color Par 56)
3 KG
(Color Par 64)
5D
3. Installation
Please checkout the voltage before applying power.
Do not connect the fixture to an electrical dimmer
System which it could damage the inside electronics
4. DMX512 Address Setting
Each fixture needs to have a start address set to receive the data sent by the controller. The
address number is between 0-511 (usually 0 & 1 are equal to 1). The address, also know as
the start channel, is the first channel used to receive instructions from the controller.
There are four ways to set the fixture DMX start address:
A. DMX address setting by dip-switches
B. Automatic
DMX-addressing
C. Remote DMX address setting by CA-T DMX TESTER
D. Remote DMX address setting by universal DMX controller
If you use the function B, C or D to set the DMX start address, the fixtures of the chain
all DIP switch MUST be set to OFF).
A. DMX address setting by dip-switches
1. Select the channels of DMX controller
2. Dipswitches
Dip
# 1
# 2
# 3
# 4
# 5
# 6
# 7
# 8
# 9
# 10
Value 1 2 4 8 16 32 64 128
256
No
Function
•
Examples:
Channel 01
:
dip / on : # 1
(
=1
)
Channel 05
:
dip / on : # 1, # 3
(
1+4=5
)
Channel 09
:
dip / on : # 1, # 4
(
1+8=9
)
Channel 13
:
dip / on : # 1, # 3, # 4
(
=13
)