FREQUENTLY ASKED QUESTIONS

Q. How do I know if the battery is charged?

A. The charger’s FULLY CHARGED LED will illuminate (solid). 

Q. I have connected the charger properly but the ‘CHARGING LED’ does not  

come on?

A. In some cases batteries can be flattened to the point where they have very little or no 

voltage. This can occur if a small amount of power is used for a long time, for example 
a map reading light is left on for a week or more. Projecta 5 Stage chargers are 
designed to charge from as little as 2V.

  If the voltage is less than 2.0V this is very low and the battery may not be rechargeable.  

You could try an electronic powersupply to gradually bring the battery voltage above 
2.0V so the charger can then take over or take the battery back to the place of 
purchase so they can try and repair it.

Q. Can I use the charger as a power supply

A. Yes, by selecting Power Supply mode you are able to use the charger as a power supply 

to run an appliance. Ensure the appliance being run is not greater than the charger’s 
output current and where possible connect the charger to a battery, and the battery  
to the appliance.

  The charger may also be used to connect to a vehicle while changing the battery  

to maintain the vehicles computer and radio settings.

Q. Why does the charger reset when I connect a load directly to the battery 

charger in Power Supply mode.

A. The charger will reset when in Power Supply mode if the load exceeds the chargers 

capacity. Some appliances when turned on or first connected to the charger will cause 
the charger to reset and it will re-try by slowly ramping up its output. 

Q. How can I tell what stage the battery charger is in?

A. Below are the conditions that are displayed by the LEDs for each of the charge stages.

14

 

 

   

 

 

Soft Start 1 

Soft Start 2 

Bulk 

Absorption/ 

Float

Blue LED 

Charging

Green LED 

Full

Red LED 

Power

(Fast Flash)

Solid On: Normal
Flashing: Fault (See Faults & Errors, page 13)

(Slow Flash)

(Slow Flash)

Summary of Contents for IC1500L

Page 1: ...INTELLI CHARGE LITHIUM 12 VOLT 5 STAGE SWITCHMODE BATTERY CHARGER P No IC1500L...

Page 2: ...ng rules Do not attempt to charge non rechargeable batteries Never charge a frozen battery If the AC cord is damaged do not attempt to use It must be replaced or repaired by a qualified person Corrosi...

Page 3: ...ltage ABSORPTION Ensures a full charge to the battery without overcharging FLOAT Float charge maintains the battery at 100 charge Soft Start 1 This is a preliminary charge that is for heavily discharg...

Page 4: ...page 13 Slow Flash Slow Flash CHARGING LED blue LED illuminates and flashes during charging process FULLY CHARGED LED green LED illuminates solid when fully charged POLARITY PROTECTION Prevents the ou...

Page 5: ...nce from a remote control display allowing the charger to be flush or surface mounted out of the way and out of sight The battery charger and remote are synchronised for operation either locally or by...

Page 6: ...nt until the battery reaches 8 0V Soft Start 2 Charge at 25 of set current until the battery reaches 10 0V Bulk Set current up to 14 5V Absorption Constant voltage of 14 5V until current drops to the...

Page 7: ...Charged Mounting Flange Temperature Compensation Probe Adjustable Charge Rate Mode Button selects between CHARGE POWER SUPPLY LED s display if in CHARGE or POWER SUPPLY Power Cord DC Leads 7 222 108 6...

Page 8: ...POWER ON CHARGE CHARGING FLOAT 15A 8A 4A 2A CHARGE RATE 12V15A5 Stage I N T E L L I C H A R G E Connection in vehicle negatively earthed STEP 1B CONNECTION IN VEHICLE Determine if the vehicle is Posit...

Page 9: ...ert the data plug into the data socket at the rear of the battery charger Cable length 4 5 metres Warning Ensure the cable is secured safely away from moving parts Installing Temperature Sensor To ins...

Page 10: ...e and the charger can be left connected to the battery without over charging If the POWER LED is flashing there is a fault refer to Fault Codes explanation on page 13 of this manual STEP 7 DISCONNECTI...

Page 11: ...x ring terminals an inline fuse holder and a fuse with a rating equal to or greater than twice the chargers output See below IC1500L 30 Amp fuse Connection 1 Cut off the supplied battery clips ensure...

Page 12: ...iances are drawing power from the battery for example like a Fridge Although the charger is designed to work with a battery connected it can also work without a battery LOCKING THE BATTERY CHARGER SET...

Page 13: ...y has not reached 10 0V after 2 hours Battery may be faulty check the battery or try and charge again F03 Fast Flash ON Fast Flash Absorption has been charging for more than 20 hours and is now in flo...

Page 14: ...er Supply mode you are able to use the charger as a power supply to run an appliance Ensure the appliance being run is not greater than the charger s output current and where possible connect the char...

Page 15: ...ability to accurately measure the battery s response to the charge being applied The battery charger has been designed to accommodate this situation although not recommended For optimum charging it is...

Page 16: ...rchase together with an explanation in writing as to the nature of the claim In the event that the claim is determined to be for a minor failure of the product then BWI reserves the right to repair or...