1.  To reduce the risk of electric shock, insure electricity has been 

turned off at the circuit breaker or fuse box before beginning.

2.  All wiring must be in accordance with the National Electrical 

Code ANSI/NFPA 70-1999 and local electrical codes. Electrical 

installation should be performed by a qualified licensed 

electrician.

3.  CAUTION: To reduce the risk of personal injury, use only the 

screws provided with the electrical box. 

4.  The outlet box and support structure must be securely mounted 

and capable of reliably supporting 35 lbs. (15.9 kg). Use only 

UL Listed outlet boxes marked “Acceptable for Fan Support of 

35 lbs. (15.9 kg) or less.”

5.  CAUTION: The fan must be mounted with a minimum of 7 

feet clearance from the trailing edge of the blades to the floor.

6.  Do not operate reversing switch while fan blades are in motion. 

Fan must be turned off and blades stopped before reversing 

blade direction.

7.  Avoid placing objects in path of the blades.

8.  To avoid personal injury or damage to the fan and other items, be 

cautious when working around or cleaning the fan.

9.  Do not use water or detergents when cleaning the fan or fan 

blades. A dry dust cloth or lightly dampened cloth will be suitable 

for most cleaning. 

10. After making electrical connections, spliced conductors should 

be turned upward and pushed carefully up into electrical box. The 

wires should be spread apart with the grounded conductor and the 

equipment-grounding conductor on one side of the electrical box 

and ungrounded conductor on the other side of the electrical box.

11. Electrical diagrams are for reference only. Light kits that are not 

packed with the fan must be UL Listed and marked suitable for 

use with the model fan you are installing. Switches must be UL 

General Use Switches. Refer to the instructions packaged with the 

light kits and switches for proper assembly.

12. All set screws must be checked and retightened where necessary 

before installation.

13. WARNING: To reduce the risk of fire or electric shock, this fan 

should only be used with fan speed control part no. UC9031, 

manufactured by Rhine Electronic Co., Ltd.

14. Suitable for use in wet locations when installed in a GFCI 

protected branch circuit.

15. Use only with light kits marked “Suitable for use in wet 

locations”.

 1. Safety Rules

READ AND SAVE THESE INSTRUCTIONS

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL 

INJURY, MOUNT TO OUTLET BOX MARKED “ACCEPTABLE FOR 

FAN SUPPORT OF 35 LBS. (15.9 KG) OR LESS”, AND USE SCREWS 

PROVIDED WITH THE OUTLET BOX.

TO REDUCE THE RISK OF PERSONAL INJURY, DO NOT BEND THE 

BLADE BRACKETS (ALSO REFERRED TO AS (“FLANGES”) DURING 

ASSEMBLY OR AFTER INSTALLATION. DO NOT INSERT OBJECTS IN 

THE PATH OF THE BLADES.

TO REDUCE THE RISK OF SHOCK, THIS FAN MUST BE INSTALLED 

WITH AN ISOLATION CONTROL/SWITCH.

Summary of Contents for AirPro P2576

Page 1: ...P2576 93089913_A...

Page 2: ...r replacement After 30 days the original purchaser MUST contact Progress Lighting at 864 678 1000 for repair or replacement which shall be determined in Progress Lighting s sole discretion and shall b...

Page 3: ...Safety Rules Unpacking Your Fan Installing Your Fan Making the Electrical Connections Operating Your Fan Care of Your Fan Troubleshooting Specifications Table of Contents 1 2 3 6 9 10 10 11...

Page 4: ...urned upward and pushed carefully up into electrical box The wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the electrical box and ungrou...

Page 5: ...t Pan 8 Light Kit Fitter Assembly 9 Glass Shade with frame 10 Wall Control 1 Mounting Bracket inside canopy 2 6 Ball Downrod Assembly hanger pin and locking pin pre attached 3 Canopy with Canopy Ring...

Page 6: ...trical box Note You may need a longer downrod to maintain proper blade clearance when installing on a steep sloped ceiling The maximum angle allowable is 30 If the canopy touches downrod remove the de...

Page 7: ...assembly Figure 7 Remove Loosen but Do Not Remove Turn Canopy Ring to Remove Figure 5 Figure 6 5 Loosen but do not remove the set screws on the collar on the top of the motor housing 6 Align the hole...

Page 8: ...electrical box Note that the flat side of the mounting bracket is toward the electrical box Figure 8 3 Tighten the two screws on the electrical box securely 4 Carefully lift the fan assembly up to th...

Page 9: ...in fuse box or circuit breaker panel remove the existing wall plate and switch 2 Proceed to make the wire connector as follows make sure the fan and light slide switches of the wall control are set in...

Page 10: ...e within 1 8 Run the fan for 10 minutes Finishing the Fan Installation STANDARD CEILING MOUNTING 1 Align the locking slots of the ceiling canopy with the two screws in the mounting bracket Push up to...

Page 11: ...not remove the other two screws Connect the wires from the light kit fitter assembly to the wires from the fan motor assembly by connecting the molded adaptor plugs together Carefully tuck all wires a...

Page 12: ...ocated at the top of the motor housing refer to figure 7 on page 4 to opposite position and turn fan on again The fan blades will turn in the opposite direction and reverse airflow Figure 16 Figure 17...

Page 13: ...TION MAKING ELECTRICAL CONNECTIONS Fan will not start Fan sounds noisy 1 Check main and branch circuit fuses or breakers 2 Check line wire connections to the fan and switch wire connections in the swi...

Page 14: ...LIGHTS WATTS AIRFLOW CFM AIRFLOW EFFICIENCY HIGHER IS BETTER CFM WATT NET WEIGHT GROSS WEIGHT CUBE FEET 52 Low 120 11 1773 161 22 05 Lbs 24 47 Lbs 2 1 Med 36 3591 100 High 58 4586 79 2017 Progress Lig...

Page 15: ...Manual de instalaci n del ventilador de techo P2576 93089913_A...

Page 16: ...as siguientes a la compra Pasados 30 d as el comprador original TIENE que contactar a Progress Lighting llamando al 864 678 1000 para reparaci n o reposici n seg n determine Progress Lighting a su en...

Page 17: ...C mo desempacar el ventilador C mo instalar el ventilador C mo hacer las conexiones el ctricas C mo usar el ventilador Cuidado del ventilador Soluci n de problemas Especificaciones Tabla de contenido...

Page 18: ...empujarse con cuidado dentro de la caja el ctrica Los cables deben estar separados con el cable y el conductor a tierra del equipo hacia uno de los lados de la caja el ctrica y el conductor sin conexi...

Page 19: ...kit de luces 9 Pantalla de vidrio con armaz n 10 Control de pared 1 Soporte de montaje dentro de la cubierta 2 Conjunto de tubo bajante bola de 6 15 24 cm con pasadores de soporte y de cierre prefijad...

Page 20: ...un techo de inclinaci n pronunciada El ngulo m ximo permitido es 30 Si la cubierta toca el tubo bajante retira la cubierta inferior decorativa y gira la cubierta 180 antes de fijarla a la placa de mo...

Page 21: ...de la parte superior de la carcasa de motor 6 Alinea los orificios en la parte inferior del tubo bajante con aquellos del collar n en la parte superior de la carcasa de motor Figura 7 Insertaconcuidad...

Page 22: ...t hacia la caja el ctrica Figura 8 3 Aprieta bien los dos tornillos en la caja el ctrica 4 Con cuidado alza el conjunto del ventilador hasta el soporte de montaje en el techo Aseg rate de que la pesta...

Page 23: ...e la forma siguiente aseg rate de que los interruptores deslizantes de la luz y el ventilador en el control de pared est n en la posici n de APAGADO OFF conecta el cable de color negro entero del cont...

Page 24: ...deben pasar de 1 8 3 2 mm Deja que el ventilador funcione por 10 minutos C mo finalizar la instalaci n del ventilador MONTAJE EST NDAR EN TECHO 1 Alinea las ranuras de cierre de la cubierta de techo c...

Page 25: ...to motor ventilador uniendo los enchufes moldeados del adaptador Coloca con cuidado todos los cables y empalmes dentro de la caja del interruptor Figura 14 4 Empuja el conjunto del soporte del kit de...

Page 26: ...do en la caja de interruptores consulta la Figura 7 de la p gina 4 hacia la direcci n opuesta y a continuaci n vuelve a encender el ventilador Las aspas del ventilador girar n en sentido contrario e i...

Page 27: ...tores principales y secundarios 2 Verifica las conexiones de cables en l nea al ventilador y de cables del interruptor en la caja de interruptores PRECAUCI N Aseg rate de que la fuente principal de el...

Page 28: ...IOS W FLUJO DE AIRE EN CFM EFICIENCIA DE FLUJO DE AIRE M S ALTO ES MEJOR CFM W PESO NETO PESO PESO BRUTO PESO PIES C BICOS 52 1 32 m Baja 120 11 1773 161 22 05 Lbs 24 47 Lbs 2 1 Media 36 3591 100 Alta...

Reviews: