- Option with outlets for latch valves (pulses) and 

minimum electric consumption. Due to its low elec-
tric consumption of the equipment and its electro-
valves, this version is very suitable for installations 
which work with a battery and which have not got 
diesel engines or solar panels. 

- Optional distance management via SMS mes-

sages, with modem GSM/GPRS included. Also, op-
tional links to a PC or an irrigation network pro-
gram. 

 

WARRANTY 

The AGRÓNIC 2000 irrigation controller meets all 

the norms set by the EC.  

The products created by PROGRÉS enjoy a two-

year warranty against all manufacturing defects. 

Compensation for direct or indirect damage 

caused by the use of the equipment is excluded from 
the warranty. 

 
 

2. INTRODUCTION TO THE MANUAL 

 

is a complete irrigation system whose 

capacity an specifications the user and installer 
should know in order to get the most out of it. For this, 
we recommend a detailed reading of this manual. 

 

The most important chapters are: 

 

2 Introduction 
4 Installation 
6 Parameters 
7 Use 

 

The INTRODUCTION is where you are at this 

moment and we recommend a thorough reading both 
for installers and users. 

The INSTALLATION is the chapter directed at the 

installer who has to connect the equipment to the 
other elements, which comprise the automatic irriga-
tion system. 

PARAMETERS is the chapter which explains how 

to configure and set up the system for the particular 
needs of each installation. This is work for the installer 
but it is also interesting for the user in case any pa-
rameters have to be modified after the installation of 
the equipment. 

The USE is the chapter aimed basically at the 

user where all the instructions for programming will be 

found. 

Start reading the chapter which best suits you, 

according to your condition of installer or user. 

Before installing the unit, it should be checked to 

see that it corresponds with your requirements. 

This can be done by checking that the identifica-

tion labels correspond with the desired model. 

To decide on the necessary model (number of 

outlets), the irrigation sectors needed, the number of 
fertilizers, mixers, fertilizer pump and filters which are 
to be used, have to be added up. 

 

 
Examples: 

-

 

If we have 2 irrigation sectors, 1 fertilizer and 2 
filters, the model 2006 is sufficient (2+1+2 
=5). 

-

 

If we have 3 sectors, 2 fertilizers, 1 mixers and 
2 filters, the model 2012 is needed (3+2+1+2 
=8). 

 

The equipment has an alphanumeric screen with 

40 characters, which shows: the questions that the 
controller asks the user, his answers, the stored pa-
rameters and programs, the current performances, the 
applied water and fertilizer quantities, the malfunctions 
and incidents, etc.  

It has also got a keyboard with 14 keys, which is 

used to access the equipment, to configure, program, 
correct, consult, erase, activate, deactivate, etc. 

The keys from 0 to 9 should be pressed when-

ever it is necessary to enter a number. 

The same keys also show the initials of the days 

of the week and they will be used whenever it is nec-
essary to enter one day in the controller. 

There are two keys with the words "YES" and 

"NO" which will be pressed, in a few cases, when one 
option or other has to be chosen (and when indicated 
on the screen) . 

There is also a key with an arrow which is used 

for moving fast through the sector numbers and pro-
grams as will be explained later. 

The "ENTER" key is used to confirm the validity of 

the data previously entered and shown on the screen 
with the cursor below it or displayed intermittently on 
the screen. This key is bigger as it is used constantly. 

The "VIEW" key is used to consult anomalies 

stored in the controllers memory, the current state of 
the inputs/outlets, etc. 

The "FUN" key is used for entering into the four 

basic functions of the controller: PROGRAMS (auto-
matic control by means of the programs entered), 
MANUAL (control by manual orders to be carried out 
immediately), PARAMETERS (configuration of the 
equipment to the particular needs of the installation) 
and TOTALS (access to the internal counters for the 
time and volume of the water and the fertilizer ap-
plied). 

 
 

Summary of Contents for Agronic 2000 Series

Page 1: ...Manual 19 7 3 Totals 19 7 4 Consultation 20 8 ADDITIONAL INFORMATION FOR VOLUME 22 8 1 Parameters 22 8 2 Programs 22 8 3 Totals 22 8 4 Consultation 22 8 5 Anomalies 22 9 ADDITIONAL INFORMATION FOR DIE...

Page 2: ...ttempts pre heating automatic stop malfunction detection etc CLEANING OF FILTERS This can be configured from 0 to 9 filters with variable washing time Pause time between filters The washing sequence c...

Page 3: ...e identifica tion labels correspond with the desired model To decide on the necessary model number of outlets the irrigation sectors needed the number of fertilizers mixers fertilizer pump and filters...

Page 4: ...n housing In the model with 26 outlets a second additional box is pro vided To maintain the isolation of the unit it is essential to keep the panels closed as well as to install cable glands at the ca...

Page 5: ...ne working that this one works without the battery as the alternator would increase the equipment power tension mo mentarily To replace the fuse half turn the fuse cover and insert another of the same...

Page 6: ...more intensity insert external re lays The outlet fuse protects from overloads and short circuits To change it just half turn the cover of the fuse holder take it out and replace it with a similar one...

Page 7: ...Electro pump 24V Rest Sectors and general outlets 24 V 1 26 26 Start 25 Stop Pre heating Electro pump Rest Sectors and general outlets 26 Start 12 V 25 Stop 12 V Pre heating 12V Electro pump 24V Rest...

Page 8: ...of 20 to 30 amps Its outlet has to be connected to the terminal cable 50 of the key If the engine stops by electromagnet a supple mentary relay will be installed between the former one and the stop o...

Page 9: ...l be con nected to the controller to the outlet corresponding to its sector or to the M general valve outlet 4 4 3 Two pump option In this option the second pump or general valve 2 will be connected t...

Page 10: ...ion for the Fulfillment of the Product Security The fulfillment of the following specifications was demonstrated as indicated in the Official Diary of the European Communities Emissions EN 50081 1 94...

Page 11: ...utes Stop of sectors when cleaning filters yes or no VARIOUS By volume yes or no Irrigation pulse value 0 to 10000 liters Fertilizer pulse value 0 to 1000 cl Assignation of functions to the inputs Del...

Page 12: ...9 Number of filters 3 If the previous screen shows that there are filters the following question corresponds to the working time for everyone of them 3 to 999 seconds and the pause between them from 0...

Page 13: ...has changed minute The input will not start again until the pro gram or its sequences of programs have finished IC FC SC TM GM CS PS 1 2 0 5 0 3 4 The following screens correspond to the detec tion de...

Page 14: ...s chosen then if the cut in the supply is less than 24 hours when it returns the unit will take up the program at the corresponding chronological point If the shortcut is for more than 24 hours when i...

Page 15: ...ations of the unit in the fol lowing screen St Start outlet Sp Stop outlet Pr Pre heating outlet Ep Electro pump outlet St Sp Pr Ep 18 17 16 15 In the diesel version it asks for the start and stop tim...

Page 16: ...hen the program has been chosen and the ENTER key pressed we are now inside and the screen will ask for the remaining details placing the cursor _ on every one of the values After introducing the firs...

Page 17: ...efined that the fer tilizers will be injected like this The programming will be the same as in series The fertilization in parallel can be done through a multihead injector or with one injector for ea...

Page 18: ...different irrigations activations in one sector or in a group of sectors only the program 1 have the variable of activation number and frequency between them The frequency time between activations ma...

Page 19: ...option has to be used very carefully due to the fact that when an outlet is activated in this way the control of malfunctions anomalies totals etc is not carried out To cancel them enter the outlet nu...

Page 20: ...F2 0 19 I 01 58 F3 0 21 F4 0 15 For every two activated sec tors a screen with their valves will be displayed In the first line shows the sector n program n with the values of the F1 F2 units left an...

Page 21: ...the unit does not allow any activation of the irrigation programs If the general malfunction input was activated all the outlets will be deactivated and the screen will show this message with the day...

Page 22: ...ing cycles 0 to 9999 m3 In various parameters the irrigation and the fertili zation are configured plus the value of the counters as already explained in section 6 1 8 2 PROGRAMS The differences in an...

Page 23: ...carried out prior to starter 9 1 CONSULTATION In the first screen of consult the letters OP will be shown at the end of the first line to indicate that the engine is working and there is oil pressure...

Page 24: ...24 NOTES R 1189 3...

Reviews: