background image

 

 

 

 

 

 

 

 

 

 

 

 INSTRUCTION 

 

 MANUAL 

   

 

 

 

            VERSION 4 

 

 
 
 

INDEX 

 

Sec.  

Theme 

Page 

 

INDEX / PRESENTATION 

1. 

BASIC FUNCTIONAL DESCRIPTION 

2. 

INTRODUCTION TO THE MANUAL 

 

Sections for the installer 

3. 

DIMENSIONS 

4. 

INSTALLATION 

4.1 

Placing the unit 

4.2 

Connection 

4.3 

Guide to malfunctions 

4.4 

Additional information for the instal-
lation of options 

5. 

TECHNICAL CHARACTERISTICS 

10 

6. 

PARAMETERS 

11 

6.1 

Fertilizer parameters 

11 

6.2 

Filter cleaning parameters 

12 

6.3 

Various parameters 

12 

6.4 

Clock parameters 

14 

6.5 

Additional information for diesel op-
tion parameters 

15 

 
 

Sections for the user

 

7. 

USE 

16 

7.1 

Programs 

16 

7.2 

Manual  

19 

7.3 

Totals 

19 

7.4 

Consultation 

20 

8. 

ADDITIONAL INFORMATION FOR 
VOLUME 

22 

8.1 

Parameters 

22 

8.2 

Programs 

22 

8.3 

Totals 

22 

8.4 

Consultation 

22 

8.5 

Anomalies 

22 

9. 

ADDITIONAL INFORMATION FOR 
DIESEL OPTION 

23 

9.1 

Consultation 

23 

9.2 

Anomalies 

23 

9.3 

Malfunctions 

23 

 

NOTES 

24 

 
 

 
 

 

PRESENTATION 

 

We wish to take this opportunity to thank you for the confidence in us which you have demonstrated in ex-

pressing interest or acquiring the AGRÓNIC 2000. 

This confidence, for our part, stimulates our efforts to meet and surpass the expectations of our clients to jus-

tify the traditional quality of our products. 

This manual will explain the specification of the equipment as well as its installation and use. 
However, if after reading this you still have any doubts, contact us and we will happily answer them.
 

Summary of Contents for Agronic 2000 Series

Page 1: ...Manual 19 7 3 Totals 19 7 4 Consultation 20 8 ADDITIONAL INFORMATION FOR VOLUME 22 8 1 Parameters 22 8 2 Programs 22 8 3 Totals 22 8 4 Consultation 22 8 5 Anomalies 22 9 ADDITIONAL INFORMATION FOR DIE...

Page 2: ...ttempts pre heating automatic stop malfunction detection etc CLEANING OF FILTERS This can be configured from 0 to 9 filters with variable washing time Pause time between filters The washing sequence c...

Page 3: ...e identifica tion labels correspond with the desired model To decide on the necessary model number of outlets the irrigation sectors needed the number of fertilizers mixers fertilizer pump and filters...

Page 4: ...n housing In the model with 26 outlets a second additional box is pro vided To maintain the isolation of the unit it is essential to keep the panels closed as well as to install cable glands at the ca...

Page 5: ...ne working that this one works without the battery as the alternator would increase the equipment power tension mo mentarily To replace the fuse half turn the fuse cover and insert another of the same...

Page 6: ...more intensity insert external re lays The outlet fuse protects from overloads and short circuits To change it just half turn the cover of the fuse holder take it out and replace it with a similar one...

Page 7: ...Electro pump 24V Rest Sectors and general outlets 24 V 1 26 26 Start 25 Stop Pre heating Electro pump Rest Sectors and general outlets 26 Start 12 V 25 Stop 12 V Pre heating 12V Electro pump 24V Rest...

Page 8: ...of 20 to 30 amps Its outlet has to be connected to the terminal cable 50 of the key If the engine stops by electromagnet a supple mentary relay will be installed between the former one and the stop o...

Page 9: ...l be con nected to the controller to the outlet corresponding to its sector or to the M general valve outlet 4 4 3 Two pump option In this option the second pump or general valve 2 will be connected t...

Page 10: ...ion for the Fulfillment of the Product Security The fulfillment of the following specifications was demonstrated as indicated in the Official Diary of the European Communities Emissions EN 50081 1 94...

Page 11: ...utes Stop of sectors when cleaning filters yes or no VARIOUS By volume yes or no Irrigation pulse value 0 to 10000 liters Fertilizer pulse value 0 to 1000 cl Assignation of functions to the inputs Del...

Page 12: ...9 Number of filters 3 If the previous screen shows that there are filters the following question corresponds to the working time for everyone of them 3 to 999 seconds and the pause between them from 0...

Page 13: ...has changed minute The input will not start again until the pro gram or its sequences of programs have finished IC FC SC TM GM CS PS 1 2 0 5 0 3 4 The following screens correspond to the detec tion de...

Page 14: ...s chosen then if the cut in the supply is less than 24 hours when it returns the unit will take up the program at the corresponding chronological point If the shortcut is for more than 24 hours when i...

Page 15: ...ations of the unit in the fol lowing screen St Start outlet Sp Stop outlet Pr Pre heating outlet Ep Electro pump outlet St Sp Pr Ep 18 17 16 15 In the diesel version it asks for the start and stop tim...

Page 16: ...hen the program has been chosen and the ENTER key pressed we are now inside and the screen will ask for the remaining details placing the cursor _ on every one of the values After introducing the firs...

Page 17: ...efined that the fer tilizers will be injected like this The programming will be the same as in series The fertilization in parallel can be done through a multihead injector or with one injector for ea...

Page 18: ...different irrigations activations in one sector or in a group of sectors only the program 1 have the variable of activation number and frequency between them The frequency time between activations ma...

Page 19: ...option has to be used very carefully due to the fact that when an outlet is activated in this way the control of malfunctions anomalies totals etc is not carried out To cancel them enter the outlet nu...

Page 20: ...F2 0 19 I 01 58 F3 0 21 F4 0 15 For every two activated sec tors a screen with their valves will be displayed In the first line shows the sector n program n with the values of the F1 F2 units left an...

Page 21: ...the unit does not allow any activation of the irrigation programs If the general malfunction input was activated all the outlets will be deactivated and the screen will show this message with the day...

Page 22: ...ing cycles 0 to 9999 m3 In various parameters the irrigation and the fertili zation are configured plus the value of the counters as already explained in section 6 1 8 2 PROGRAMS The differences in an...

Page 23: ...carried out prior to starter 9 1 CONSULTATION In the first screen of consult the letters OP will be shown at the end of the first line to indicate that the engine is working and there is oil pressure...

Page 24: ...24 NOTES R 1189 3...