1. It is strictly prohibited to move the product from the toilet cover, otherwise easy
to cause mechanical failure.
2. It is strictly prohibited to connect hot water above 40
℃
and cold water that may
lead to icing.
Prohibit
ed
5.Slightly push the
bidet seat
into
the fixing
plate in the specified direction until
a
"click"
sound is heard, indicating that the
bidet seat
has been installed in place.
CLIC
K
4.The installation template is designed for
one- time use. Please discard it after the
installation is completed.
Connect water pipes
3B.
Turn on the water supply and check for
water leakage.
Note:There are two methods of pipe connecting
1A.
Turn off the water supply
and remove the
water
supply hose connected to the water
tank.
Connect t
he three-way
T-junction
to
the angle valve
,
ensur
ing
the rubber
sealing ring is
properly seated.
2A.
Install
the filter and rubber
sealing ring
on
the water inlet hose
and
connect
as shown.
3A.
Turn on the water supply
and
check for
water leakage.
Rubber
gasket
Filter
1B.Turn off the water supply.
2B.
Connect the three-way T-junction to the
bottom of the water inlet valve on the
toilet. Install the filter and rubber sealing
ring on the water inlet hose and connect
as shown.
E
A
D
B
C
Gasket
Filter
Installation Steps
11