Night light analysis
Phenomenon
Possible cause
Night light is not ON.
Knob light is not ON
Power cord of night light shows poor contact
Power cord of knob light shows poor contact
Night light is damaged
Common fault diagnosis
1.
If power supply is under normal state.
2.
If
surge
protector trips
1.
If water supply is under normal state.
2.
If
water inlet
valve is closed.
If the following occurs, cut off the power supply immediately.
The buzzer continues to beep
The
surge
protector trips frequently
Note: When water leakage occurs, close the
water inlet
valve
and
cut off the power supply.
Seat heating failure a
nalysis
Cut off the power supply, close the
water inlet
valve and contact
an
authorised technician
.
Cut off the power supply,
close the
water inlet valve and contact an
authorised technician
.
Reset
Control K
nob to OFF
Phenomenon
Possible cause
Solution
Base gap leakage
Flushing module
leakage
Pressure maintaining valve is
damaged
Control
Knob is not
reset to OFF position
Control valve is failed
Flushing failure analysis
Water leakage analysis
Phenomenon
Possible cause
Solution
Seat temperature is
not sufficient
Seat temperature is set at low
gear
Adjust seat temperature to higher gear.
Seat temperature is
too high
Seat temperature is set at high
gear
Adjust seat temperature to lower gear.
Temperature is too
low when
making
contact with
the
seat
S
eat heating function
not enabled
Cut off power supply
and contact an
authorised technician
.
Enable seat heating function in advance.
No seat heating
function
Seat heating coil in poor contact.
If
you think
the bidet seat ha
s a fault, try some of the following process methods. If the product is
still not
working properly, contact
an authorised technician or electrician
.
Check power supply
Check water supply
Phenomenon
Possible cause
Solution
Spray tube extends too
slowly
Cool water should be released
from front end before flushing.
Insufficient water amount
Control
Knob is not
completely turned on.
Insufficient water
temperature
Water temperature is set at low
gear.
W
ater temperature
too low
Water temperature is set at
lowest gear.
Automatic protection for
over-high temperature
Water flow
s
out
when seated
Self-cleaning function is enabled.
It is normal, and provides normal flushing
about 5 s
econds
later.
Increase
Control K
nob regulating angle.
Adjust water temperature to higher gear.
Adjust water temperature to higher gear.
Restart water temperature adjustment.
It is normal, and
water flow
automatically
stop
s
about 5 s
econds
later.
Water is not heated
Breathing light not flash
ing
The flowmeter is abnormal
Cut off power supply
and contact an
authorised technician
.
Faults & Troubleshooting
16