background image

Part No. 138228 G01131AC R0198A

Printed in USA © 1998 Sears, Roebuck and Co.

Model No. 831.210020

QUESTIONS?

As a manufacturer, we are commit-
ted to providing complete customer
satisfaction. If you have questions,
or find that there are missing or
damaged parts, we will guarantee
complete satisfaction through direct
assistance from our factory. 

TO AVOID UNNECESSARY DELAYS,
PLEASE CALL DIRECT TO OUR
TOLL-FREE CUSTOMER HOT LINE.
The trained technicians on our cus-
tomer hot line will provide immedi-
ate assistance, free of charge to
you.  

CUSTOMER HOT LINE:  

1-800-999-3756

Mon.ÐFri., 6 a.m.Ð6 p.m. MST

ORDERING REPLACEMENT
PARTS

To order replacement parts, simply call our Customer Service
Department toll-free at 1-800-999-3756, Monday through Friday, 6
a.m. until 6 p.m. Mountain Time (excluding holidays). To help us
assist you, please be prepared to give the following information
when calling:

1.  The MODEL NUMBER of the product (831.210020).

2.  The NAME of the product (RESTORATION 2.0 by

PROFORM

¨

).

3.  The SERIAL NUMBER of the product (see the front cover of

this manual).

4.  The KEY NUMBER and DESCRIPTION of the desired part(s)

(see the PART LIST on page 18 of this manual).

Summary of Contents for 831.21002

Page 1: ...above CAUTION Read all precautions and instruc tions in this manual before using this equipment Save this manual for future reference Serial Number Decal on the frame behind the access cover SEARS RO...

Page 2: ...r maintenance or any damage to the wood or tile exterior attributable to freight mishandling damage resulting from improper winterization damage to the spa shell resulting from improper chemical treat...

Page 3: ...empty The surface of the spa shell can reach temperatures as high as 150 F in a matter of minutes if exposed to the sun while it is empty These high temperatures can cause significant damage such as b...

Page 4: ...the RESTORATION 2 0 by children Children must always be super vised 28 DANGER To reduce the risk of drowning Never use the RESTORATION 2 0 alone Children should not use the RESTORATION 2 0 unless the...

Page 5: ...an 37 WARNING To reduce the risk of injury It is especially important for persons over the age of 35 or persons with pre existing health problems such as obesity heart disease high or low blood pressu...

Page 6: ...0 gives you the specialized treatment you need to feel your best For your safety and benefit read this manual care fully before using the PROFORM RESTORATION 2 0 If you have additional questions pleas...

Page 7: ...k system that is built flush with the top of the spa provided you leave access to the motor for service 9 Be sure to note any other considerations such as aesthetics or privacy concerns which may affe...

Page 8: ...see step 1 above 3 Wipe out the spa shell using a damp cloth Remove the two warning decals not shown from the spa shell Before you fill the RESTORATION 2 0 be sure that it is in the position you want...

Page 9: ...Position one of the Buckles 2 on the wood panels on the Spa Unit 15 and hold the Buckle in place so the strap on the Spa Cover 13 is tight Note It may be easier to posi tion the Buckles if a second pe...

Page 10: ...t UP However the directions on the bottle of Non chlorine Shox and Bromine Base are correct Always keep the chemicals away from children and pets The first time you use the spa you should test and tre...

Page 11: ...F Do not enter the spa Add cold water to reduce water tempera ture You must unplug the power cord and plug it back in to reset the spa the spa will not operate until it has been reset If the spa repe...

Page 12: ...spa cover into the buckles on the side panels The buckles can be locked by inserting the key and turning it clockwise a quarter turn To unlock the buckles insert the key and turn it counter clockwise...

Page 13: ...THE SPA EXTERIOR The wood panel exterior has been treated with a sealant at the factory to protect the wood from water damage We suggest that you treat the wood finish twice a year with an additional...

Page 14: ...ore The pH reading should be between 7 2 and 7 8 If the level is too low add a pH increaser usually soda ash If the level is too high add a pH reducer usually sodium bisulfate Test the water again aft...

Page 15: ...into the closed position and turn the handles until they lock into place If you are planning to work on the pump motor you will also need to drain the pump see page 14 To open the valves turn the han...

Page 16: ...OT HEAT a The pump in the spa jet unit is the heater If the pump is operating the water should heat Cover the RESTORATION 2 0 with the spa cover The spa cover must be tight with the insulation blanket...

Page 17: ...s will not function properly 10 SYMPTOM THE WATER LEVEL DROPS a Some water loss due to evaporation is normal If rapid water loss occurs or if you notice wet ness on the floor around the RESTORATION 2...

Page 18: ...cal 15 1 Spa Unit 16 1 Sun Warning Decal 17 1 Filter Housing 18 1 Housing Ring 19 2 Cover Screws 20 1 Filter Cover 21 1 Filter 22 1 Suction Cover Screw Key No Qty Description 23 1 Suction Cover 24 1 A...

Page 19: ...33 32 22 23 37 26 27 36 25 35 1 2 3 4 5 6 8 9 10 11 12 13 15 2 14 16 7 19 20 21 17 18 34 30 31 24 28 29 29 28 EXPLODED DRAWING Model No 831 210020 R0198A 19...

Page 20: ...will provide immedi ate assistance free of charge to you CUSTOMER HOT LINE 1 800 999 3756 Mon Fri 6 a m 6 p m MST ORDERING REPLACEMENT PARTS To order replacement parts simply call our Customer Service...

Reviews: