background image

752496-100 Rev. H

© American Standard Inc. 2003
All product names listed herein are trademarks
of American Standard Inc. unless otherwise noted.

FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.

T H A N K     Y O U . . .

for selecting an American Standard bath. Your new 
bath is shipped to you after careful inspection. The 
whirlpool version is completely assembled with pump, 
motor, and system piping. All you need to finish the 
installation are your selected fittings and electrical 
connections for a whirlpool.

To insure maximum performance and pleasure from 
this product, please follow the instructions and 
cautions. 

GENERAL INSTALLATION INFORMATION

Carefully uncrate and inspect your new bath for any shipping damage. If such damage is found, report it to your vendor 
immediately.

After inspection and during installation, protect the bath from construction damage. After installation, and before 
enclosing with wallboard, tile, etc., water test the unit and check for leaks.

Do not make modifications to the whirlpool system or remove pump from factory mounting. This could adversely affect 
the safety and performance of the whirlpool and void the warranty. Do not handle or move the whirlpool by the pump, 
motor, or piping system.

Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and 
enclosing materials are provided by others. Check for availability of optional American Standard wall tiling bead 
(required for recess installations).

Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth.  

WARNING! Do not lift whirlpool by the piping harness at any time.

List of Optional Components (not included):
•  Safe-T-Heater 9075.120*
•  Tile Bead Kit 751755-100*
•  Apron Kit*
* see your American Standard Distributor
 
List of Required Components (not included):
•  Drain 1583.470*          •  Bath Filler*
* see your American Standard Distributor

List of Required Tools and Supplies:

Tools
•  Level
•  Tape Measure
•  Pipe Wrench
•  Slip Joint Pliers
•  Screw Driver
•  Standard
      Woodworking Tools
•  Personal Safety
      Equipment
•  Caulking Gun

Supplies
•  Nails
•  Putty
•  Caulking (waterproof)
•  1 x 3 or 2 x 2
      Stringers
•  Drop Cloth
•  20 amp GFI
      Outlet
•  Cement, Plaster,
      Grout

INSTALLATION INSTRUCTIONS

HIGH GLOSS ACRYLIC
SHOWN LESS ALL FITTINGS

CADET™
6' x 36"

WHIRLPOOL/BATHING POOL

2773.XXXW SERIES

  72 x 35-3/4 x 19-3/4 In.

(1829mm x 908 mm x 502mm)

101 Lbs. (45 Kg.)

751 Lbs. (341 Kg)

78 Gal. (295 L.)
64 Gal. (242 L.)

23 x 49 In. (584 mm x 1245 mm)

65 x 29 In. (1651 x 737 mm)

13-1/2 In. (343mm)

40 Lbs./Sq. Ft. (190 Kgs/Sq. m.)

23.8
48.3

GENERAL SPECIFICATIONS FOR 2773 WHIRLPOOL

INSTALLED SIZE

WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
MIN. OPERATING GAL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT

3

)

WHIRLPOOL ELECTRICAL SPECIFICATIONS

2.1 HP, 14.4 AMPS, 120V.

PUMP

464 mm
(18-1/4)

38 mm

(1-1/2)

502 mm
(19-3/4)

1-1/2 O.D.TAILPIECE

■ 

LEVELING STRINGER

NOT FOR SUPPORT 

ROUGH

FLOOR

70mm

(2-3/4)

305mm

(12)

OPTIONAL TO 

FINISHED FLOOR 

USUALLY BETWEEN

1651 & 1981mm 

(65 & 78)

C/L OF
OVERFLOW

102 mm

(4)

C/L OF
SPOUT

C/L OF
VALVES

C/L OF
SHOWER ARM

70 mm

(2-3/4)

 117 mm

(4-5/8)

1-1/2 N.P.T.M.

THREADS

INTEGRAL

SUPPORT

FEET

SAFE-T-HEATER
REMOVABLE
BLANK

RECOMMENDED FITTING LOCATION

64 X 330mm (2-1/2 x 13")

FOR PIER OR ISLAND

INSTALLATIONS ONLY

ALT. FITTING

LOCATION #1

1829 mm

(72)

908 mm
(35-3/4)

OUTLINE OF CUTOUT 
1791 mm x 870 mm
(70-1/2 X 34-1/4)

454 mm
(17-7/8)

229mm

(9)

305 mm

(12)

57mm

(2-1/4)

(8) JETS

CUTOUT IN FLOOR
FOR DRAIN

PUMP

FINISHED

WALL

19 mm

(3/4)

229 mm

(9)

C/L OF

SUPPLIES

C/L OF DRAIN

SEE FITTING

SPECS FOR

DIMENSIONS

(2) AIR VALVES

ON/OFF
SWITCH

PROVIDE ACCESS TO PUMP FOR

SERVICING ON ALL INSTALLATIONS

Reviews: