User manual Profline SFM.
© Profline
Specifications are subject to change without notice
COMM
The submenu "COMM" is used for communication through the RCDS-bus at the back. RCDS stands for Remote Control and
Diagnostics System and is used for complete remote controlling of the SFM.
When selecting the submenu "COMM" the following subjects can be adjusted:
-
MESSAGES Disabled/Enabled
-
BAUD
1200
-
19200 ( 1200,2400,4800,9600,19200)
-
ADDRESS 00 - 3F (Hex)
-
TEST MESSAGE When activating this function, the SFM is announced to the RCDS-system
ALARM
When selecting the Alarm submenu the following alarm-outputs/messages can be installed:
-
PLL
OFF/ -A- / -B-
-
INPUT
OFF/ -A- / -B-
-
TEMP
OFF/ -A- / -B-
-
ASD
OFF / -A- / -B- (when installed)
-
IQD
OFF/ -A- / -B- (when installed)
The alarm will become active when:
-
PLL: When the PLL is out of lock
-
INPUT: When for a period of 5 minutes no audio is detected
-
TEMP: When the internal temperature of the SFM becomes higher then 65°C
-
ASD: When RF-input level drops under the Squelch level
-
IQD: When there is a loss of sync (no-data / corrupt-data)
When an alarm has been detected and the submenu "ALARM" is selected, there is an indication wilt "* *" which indicates
that this alarm is active (example *A* = alarm A is active).
Alarm connector: Sub D9 Female:
Connections:
-A alarm: 7= Common 8=NO 9=NC
-B alarm: 3= Common 4=NO 5=NC
Connections at the back
From left to right:
Mains connection
IEC panel mount plug with fuse or DIN 11122 when using 48VDC
Alarm A/B
Sub D9 female
RCDS
Sub D9 male
RF-test output - 20 dB
BNC
RF output
BNC
Audio input right
XLR male
Audio input left
XLR male
Coder I/O
Sub D9 female
Input option
BNC (ASD) XLR-male (IQD)
COM-RDS
Sub D9 male (when installed)
Ground chassis
M6