ENERGY CONSUMPTION METER
UK - 1
PCF-605
Thank you for purchasing this Profile product. Please
note: It is important that you read this manual before
using the product. And be sure to save this manual for
possible use later.
Please note
The Energy Meter must be charged before use. After
15 minutes, the LCD screen will be operational, but
to fully charge the battery, the device must be
plugged into the mains for at least 12 hours.
The Energy Meter is the easiest way for you to measure
the energy costs of connected appliances.
Correct use
The measurement range of the Energy Meter is 5W to
3680W. Exact measurement of values below or above
this range is not possible. Use outside this range can
overload and damage the unit.
The Energy Meter was designed to monitor and
measure electric appliances.
The Energy Meter is approved only for use with 230V
AC.
Only 230V AC, 50/60Hz electric appliances may be
connected.
The maximum power of the connected loads may not
exceed 3680W (maximum amperage 16A).
Use of the Energy Meter is only allowed indoors in
dry environments. Use in the open air is strictly
prohibited!
Always heed the instructions on the identification
label located on the connected power cables.
Use other than that described above can result in
damage to the product and the risk of short circuit,
fire, electric shocks, etc.
The product as a whole may not be converted or
modified. The safety instructions must be followed
strictly.
Safety instructions
The manufacturers accept no liability for damage to
objects or persons that arises from incorrect use or
noncompliance with the safety prescriptions. All
damage claims resulting in such cases are void.
The Energy Meter may only be connected to
regulated outlets (230V AC, 50/60Hz- 10/16A) with a
ground.
The connected appliances may not use more than
3680W (16A).
The operating temperature of the connected
appliance must be between 10º and 40º.
High temperatures, especially when measuring high
levels of electrical power, can result in overheating
and damage to the Energy Meter.
Avoid use in extreme weather conditions and in the
vicinity of inflammable gases, moisture and dust.
For safety reasons, the unit may never be operated in
a wet or damp environment.
During cleaning or maintenance, disconnect each
source of power from the Energy Meter. The battery
and the LCD screen can retain a charge, even when
the unit is disconnected from all sources of power.
Insert no metal parts or other objects in the Energy
Meter.
If it is established that safe use is no longer possible,
take the Energy Meter out of operation and ensure
that it is not mistakenly put back into operation by
someone else. If there is visible damage to the Energy
Meter, it must be taken out of service immediately.
Features
Display of current time (24-hour clock), day, energy
consumption in Watts and billing rate.
Display of total time connected, energy consumed
and the cost of energy consumed.
Display of total registered times, total time and
percentages.
Programmable day and night rates.
Configuration, connection and operation
The procedure for setting the time and the billing rate
is the following:
Setting the current time and day
1. Simultaneously press the “MODE”,
“+” and ”-“ buttons to enter the
system configuration. The first setting
is the current time.
2. Use the “+” button to increase the
value of the flashing position from 0
to 9; use the “-“ button to decrease the value of the
flashing position.
3. Press the “MODE” button to move the next position.
4. After setting the day, push the “MODE” button again –
billing rate 1 for the system can now be configured.
Setting billing rate 1 (day
rate)
1. Set the start time for billing
rate 1. For example day rate
starts at 7.00 a.m.
2. Set rate 1. For example €
0.10 per Kwh.
3. Use the “+” button to increase the value of the
flashing position from 0 to 9; use the “-“ button to
decrease the value of the flashing position.
4. Press the “MODE” button to move to the next
position.
5. Press the “MODE” button - billing rate 2 for the
system can now be configured.
Setting billing rate 2 (night
rate)
1. Set the start time for billing
rate 2. For example, the night
rate starts at 9.00 p.m.