14
STEP 3CS – Set for STANDARD or PRE SERVICE RINSE. This display is used for setting
pre-service rinse in some applications. Factory default is Std Rinse.
Press NEXT to go to Step 4CS. Press REGEN to return to previous step.
STEP 4CS – The factory default is to set AUX MAV to off, unless the pre-service rinse is used.
STEP 5CS – Press the
or
buttons until selection of first cycle appears in the display, in this
example FILL is selected. Press NEXT to go to Step 6CS. Press REGEN to return to previous
step.
STEP 6CS – Press the
or
buttons until selection of second cycle appears in the display, in
this example SOFTENING is selected. Press NEXT to go to Step 7CS. Press REGEN to return
to previous step.
STEP 7CS – Press the
or
buttons until selection of third cycle appears in the display, in
this example BACKWASH is selected. Press NEXT to go to Step 8CS. Press REGEN to return
to previous step.
STEP 8CS – Press the
or
buttons until selection of fourth cycle appears in the display, in
this example dn BRINE is selected. Press NEXT to go to Step 9CS. Press REGEN to return to
previous step.
STEP 9CS – Press the
or
buttons until selection of fifth cycle appears in the display.
Press NEXT to go to Step 10CS. Press REGEN to return to previous step.
STEP 10CS – Press the
or
button until last regeneration cycle; END appears (up to 9
regeneration modes are possible). End must be selected as last cycle.
STEP 11CS – Set ALT FILL TRIGGER to off using the
or
buttons. Press NEXT to
complete programming.
STANDARD
STEP 3CS
STEP 5CS
1
fill
STEP 8CS
4
dN BRINE
STEP 6CS
2
softening
STEP 7CS
3
BACKWASH
STEP 9CS
5
RINSE
STEP 10CS
6
END
OFF
STEP 4CS
SET TYPE
SET AUX MAV
STEP 11CS
OFF
ALT FILL