12
DIAGNOSTICS
STEP 1D
STEP 2D
2
➔
REGEN
DAY
STEP 3D
342
➔
REGEN
GAL
STEP 4D
A- 6
➔
DAY
33
GAL
75
GAL
STEP 5D
- 1
➔
REGEN
DAY
STEP 6D
12.7
➔
GAL
MIN
RETURN TO NORMAL MODE
=
Up Arrow =
Down Arrow
Reset Diagnostic Values: Hold NEXT/DOWN buttons for 3 seconds, then hold UP/DOWN buttons for 3 seconds.
STEP 4D – Volume of reserve capacity used for last 7 days: If the
unit is set up as a softener, a meter is installed and Set Volume Capac-
ity is set to "Auto", this display shows 0 day (for today) and flashes the
reserve capacity. Pressing the
button will show day 1 (which would
be yesterday) and flashes the reserve capacity used. Pressing the
button again will show day 2 (the day before yesterday) and the reserve
capacity used. Keep pressing the
button to show the capacity for
days 3, 4, 5 and 6. The
button can be pressed to move backwards in
the day series. Press NEXT button at any time to go to Step 5D. Press
REGEN to return to previous step.
STEP 5D – Volume of water used, 63-day usage history: This
display shows day 1 (for yesterday) and flashes the volume of water
treated yesterday. Pressing the
button will show day 2 (which would
be the day before yesterday) and flashes the volume of water treated
on that day. Continue to press the
button to show the volume of
water treated for the last 63 days. If a regeneration occurred on the
day the word "REGEN" will also be displayed. This display will show
dashes if a water meter is not installed. Press the NEXT button at any
time to go to Step 6 D. Press REGEN to return to the previous step.
STEP 1D – Press
or
simultaneously for three seconds. If screen in step 2D does not appear
in 5 seconds the lock on the valve is activated.
STEP 2D – Days, since last regeneration: This display shows the days since the last regeneration
occurred. Press the NEXT button to go to Step 3D. Press REGEN to exit Diagnostics.
STEP 3D – Volume, since last regeneration: This display shows gallons of water that has been
treated since the last regeneration. This display will equal zero if a water meter is not installed.
Press the NEXT button to go to Step 4D. Press REGEN to return to previous step.
STEP 6D – Flow rate, maximum last seven days: The maximum flow rate in gallons per minute that
occurred in the last seven days will be displayed. This display will equal zero if a water meter is not
installed. Press the NEXT button to exit Diagnostics. Press REGEN to return to the previous step.
To reset diagnostic data push "Next" and
button for 3 seconds, release when softening appears
in window, then press "
&
"
button simultaneously for 3 seconds.