7. maIntenanCe

7.1 CLEANING AIr INTAKE FILLEr

Air intake fi lter will become blocked and start to reduce the performance of the pump over time, 

therefore it is necessary to check it frequently and replace it when you fi nd it blocked or dirty.

l

  Simply remove the air intake cover in rear 

of the pump base.

l

  remove and replace the air intake fi lter

l

  repeat step 1 and 2 in reverse order to 

reassemble.

7.3 FrOST

Frost can cause damage to the pump. In freezing the pump and pipes must be 

emptied, rinsed with clean water and stored dry.

7.2 rEPLACING BATTErY (OXYGEN 4) 

rechargeable battery will become less effi cient with repeated charge and discharge cycles.The 

capacity of the battery may also reduce over time, therefore it is necessary to replace battery 

every 12-18 months as a minimum or more frequently depending on daily using conditions.

l

  remove the base screw x4pc from the 

pump base.

l

  Partially remove the pump cover lid

l

  Slightly Disconnect the battery lead from 

the pump cover lid, then remove and 

replace the battery.

l

  repeat the step 1 and 2 and 3 in reverse 

order to reassemble.

Tools Need:
Small sized Philips head screwdriver.
Dispose of old battery according to your 

local regulations, recycle when possible.
Only the original battery should be used 

for replacement as other alternatives may 

damage the product and will void the 

guarantee.

8. troublesHootInG

8.1 LOW AIr OUTPUT / NOISY OPErATION

l

   Is the pump on a sounding board, such as a wooden shed fl oor, if so place the pump on a 

patio slab that will reduce the effect (see section 5)

l

  Are the air lines kinked

l

  Placing the air stones deeper in the water increases the back-pressure on the pump, as it 

must work harder it may become noisy (see section 4.3)

l

  Check and replace old blocked and dirty air stones

l

  Check and clean blocked and dirty air intake fi lter (see section 7.1)

8.2 NO AIr OUTPUT / PUMP STOPPED

l

  Check connections between pump and solar panel

l

  Check solar panel positioned correctly to receive direct sun light (see section 4.2), leave it 

charging under good direct sun light for a while and recheck later.

l

  Intake fi lter may be severely blocked, need to clean the air intake fi lter (see section 7.1)

l

  Battery (only Oxygen 4) may have reached its life span, need to replace the battery (see sec-

tion 7.2)

9. seCurIty tIPs

 

l

 Obey absolutely valid regulations on the electrical security 

 

l

 Pumping infl ammable, as well as all other aggressive liquids is prohibited

 

l

 Never pull the pump on the electrical cable or hose

 

l

 Avoid cross section narrowing

 

l

  During longer unused times, clean the air pump and store it at room temperature

 

l

  The pump may be used by children aged 8 years and above as well as persons with 

reduced physical, sensory or mental abilities or those who lack skills, experience and 

knowledge only if they are supervised. These aforementioned persons should only use 

the appliance while adhering to safe instructions and resulting dangers.

 

l

  Cleaning and maintenance must not be carried out by children without supervision.

tHe manuFaCturer exPlaIns:

l

  To take over no responsibility in the case of accidents or damages on the basis of careless-

ness or disregard to the instructions in this manual.

l

  To reject every responsibility for the damages which originate from the improper use of the 

device.

10. Guarantee reGulatIons

For all manufacturing and material defects, the statutory warranty applies. In these cases we 

take the replacement or repair of the device. Shipping costs shall be borne by our company, 

except as required by law. Please report the warranty on our service platform http://www.profi -

pumpe.de/service.php. We will inform you how to proceed with case-related. returns please 

suffi cient postage. Unfortunately not prepaid returns can not be accepted because they are 

fi ltered out before delivery. Our service we provide in Germany.

The warranty does not cover:

l

 Material wear (sealing rings, impeller wheels, impeller chambers)

l

 Unjustifi ed interventions or changes in the pump

l

 Damages by selffault

Air 

intake 

cover

Air intake 

filter

Pump 

cover lid

Battery

connector

Battery

Pump base

Base screw x4

Air 

pump

Motor connector

Summary of Contents for Oxygen-3.1

Page 1: ...s misprints and mistakes reserved Newest information about our products can be found online Technische änderungen Druckfehler und Irrtümer vorbehalten Aktuelle Informationen zu unseren Produkten finden Sie auf http www profi pumpe de teichbelüfter set solar oxyGen 3 1 SP01130 teichbelüfter set solar oxyGen 4 SP01131 ...

Page 2: ...ase observe all safety precautions and instructions for proper use of the pump Failure to follow the instructions and safety precautions can result in inju ry or property damage Please keep this manual with the instructions and safety instructions carefully in order to at any time you can restore them 3 delivery and construction Unpack all components carefully You should have received the followin...

Page 3: ...battery runs out of all power The pump will automatically re start when the battery has been re charged The Pulse timing mode is designed to save the battery power when poor weather We recom mend you use this mode to extend the pump s daily working time in winter or in cloudy days l Battery power low When you find the indicator light is red light blinking on that means the battery power is too low...

Page 4: ...oned correctly to receive direct sun light see section 4 2 leave it charging under good direct sun light for a while and recheck later l Intake filter may be severely blocked need to clean the air intake filter see section 7 1 l Battery only Oxygen 4 may have reached its life span need to replace the battery see sec tion 7 2 9 seCurIty tIPs l Obey absolutely valid regulations on the electrical sec...

Page 5: ...rmonized standards EN 55014 1 2006 A1 2009 A2 2010 EN 55014 2 2015 Wiesbaden 12th November 2017 ppa Peter Neumüller l Improper servicing and improper use l DRY RUNNIG Also partially of the pump Moreover we give no damage compensation for secondary damages 1 Vorwort Zum Kauf unserer Teichbelüfters möchten wir Sie recht herzlich beglückwünschen Wir wissen Ihr Vertrauen zu schätzen Aus diesem Grund s...

Page 6: ...Sie diesen Vorgang für den anderen Ausgang Befestigen Sie den Luftansaugdeckel am Pumpenfuß Schließen Sie die Teichbelüfter mit dem mitgelieferten Ka bel an das Solarmodul an Um eine maximale Belüf tung des Teiches zu ge währleisten empfehlen wir die Luftsteine mit Hilfe der mitgelieferten Schwimmer innerhalb von 30 cm Tiefe unter dem Teichwasser spiegel zu platzieren 4 Montage 4 1 Solarpanel Verb...

Page 7: ...dus wurde entwickelt um die Batterieleistung bei schlechtem Wetter zu schonen Wir empfehlen Ihnen diesen Modus zu verwenden um die tägliche Betriebszeit der Pumpe im Winter oder an bewölkten Tagen zu verlängern l BATTErIELEISTUNG GErING Wenn Sie feststellen dass die Anzeigelampe rot blinkt d h die Batterieleistung zu niedrig ist schaltet sich die Pumpe kurzzeitig ab um die Batterie zu schützen Lad...

Page 8: ... dies gesetzlich vorgeschrieben ist Im Garantiefall bitte über unsere Serviceplattform http www profi pumpe de service php den Fall an melden Dann teilen wir Ihnen die weitere Vorgehensweise fallbezogen mit Rücksendungen bitte ausreichend frankieren Unfreie Rücksendungen können leider nicht angenom men werden da diese vor Zustellung rausgefiltert werden Unsere Serviceleistung erbringen wir in Deut...

Page 9: ...umpe de weitere Zubehör und Ersatzteile erhältlich English Deutsch Teichbelüfter OXYGEN 3 1 SP01130 Teichbelüfter OXYGEN 4 SP01131 Pump Power Leistung 1 4Watt 2 5Watt Max pump capacity Max Fördermenge 2x60l h 2x60l h Max water temperature Max Wassertemperatur 40 C 40 C Solar module Rated voltage Nennspannung 5V 5V Amperage Stromstärke 320mA 500mA Power Wattleistung 1 6Watt 2 5Watt Dimension LxWxH ...

Reviews: