8. SERVICING
8QGHUQRUPDOSXPSLQJFRQGLWLRQVWKHSXPSUHTXLUHVQRVHUYLFLQJ)URPDQRSHUDWLQJ
SHULRGZLWKFOHDUZDWHURIDSSUR[KRXUVWKHPHFKDQLFDOFRPSRQHQWVVKRXOGEH
FKHFNHGLPSHOOHUZKHHOVFKDPEHUVVHDOLQJULQJVHWFRQZHDUDQGLIQHFHVVDU\EH
FKDQJHG$IWHUSXPSLQJKRXUVWKHRLOLQWKHFKDPEHUVKRXOGDOVREHFKDQJHGLI
QHFHVVDU\RQO\ZLWKRLOGLSSHGHQJLQHW\SHV3OHDVHRQO\¿OOLWXSWRDQGFKHFN
WKHVHDOLQJULQJVDOZD\VIRUGHQVLW\
:LWKDEUDVLYHPDWHULDOVOLNHVDQGWKHVHUYLFLQJGXUDWLRQFDQEHFRPHVKRUWHU
7KHIROORZLQJFRQWUROVVKRXOGEHFDUULHGRXWUHJXODUO\
z
Intactness of the electric cable
z
That the connection hoses are not bent or broken
z
&OHDQQHVVRIWKHSXPSPHGLXP
0RUHRYHUWKHSXPSVKRXOGEHHPSWLHGZLWKULVNRIIURVWEHZDVKHGRXWZLWKFOHDUZDWHU
DQGVWRUHGGU\
10. RECOGNISING AND REPAIRING OF MISTAKES
Problem
Possible cause
Solution
Pump runs, no water is
being pumped
$LULQWKHV\VWHPFDQQRWHV
cape)
$LULQWKHV\VWHPPXVWEHOHWRXW
Impeller wheel is blocked
Impeller wheel must be cleaned
3XPSGRHVQRWVWDUWRUVZLW
ches itself off
(QJLQHJXDUGKDVVZLWFKHGWKH
pump off
Pump needs to be cooled
1RHOHFWULFLW\
&KHFNHOHFWULFDOFRQQHFWLRQV
3XPSUXQV3XPSFDSDFLW\
slows down or stops
Pump is inserted to deep
Insert pump not so deep
+RVHFRQQHFWLRQVV\VWHPV
have a leak
&KHFNKRVHFRQQHFWLRQV\VWHPV
Impeller wheel is worn down
&KDQJHLPSHOOHUZKHHO
)LOWHUKDVEHFRPHGLUW\
&OHDQ¿OWHU
7. SECURITY TIPS
z
2EH\DEVROXWHO\YDOLGUHJXODWLRQVRQWKHHOHFWULFDOVHFXULW\
z
1HYHUUXQSXPSGU\
z
3XPSLQJLQÀDPPDEOHDVZHOODVDOORWKHUDJJUHVVLYHOLTXLGVLVSURKLELWHG
z
3D\DWWHQWLRQWRWKHPHGLXPWHPSHUDWXUHPD[&
z
Never pull the pump on the electrical cable or pressure hose
z
Avoid cross section narrowing
z
3D\DWWHQWLRQWRWKHJLYHQSDUWLFOHVL]H
z
'XULQJORQJHUXQXVHGWLPHVFOHDQWKHSXPSZDVKLWRXWZLWKFOHDUZDWHUGU\DQGVWRUH
it at room temperature
z
7HVWZHOOVIRUHQRXJKÀRZLQJZDWHUGU\UXQGDQJHU
z
7KHSXPSLVWREHVHFXUHGWKURXJKD5&'FLUFXLWEUHDNHUZLWKDUHOHDVHFXUUHQW
RIP$
z
7KHHOHFWULFDOFRQQHFWLRQVDUHDOZD\VWREHFDUULHGRXWE\DQDXWKRULVHGSURIHVVLRQDO
z
7KHSXPSPD\EHXVHGE\FKLOGUHQDJHG\HDUVDQGDERYHDVZHOODVSHUVRQVZLWK
UHGXFHGSK\VLFDOVHQVRU\RUPHQWDODELOLWLHVRUWKRVHZKRODFNVNLOOVH[SHULHQFHDQG
NQRZOHGJHRQO\LIWKH\DUHVXSHUYLVHG7KHVHDIRUHPHQWLRQHGSHUVRQVVKRXOGRQO\XVH
WKHDSSOLDQFHZKLOHDGKHULQJWRVDIHLQVWUXFWLRQVDQGUHVXOWLQJGDQJHUV
z
&OHDQLQJDQGPDLQWHQDQFHPXVWQRWEHFDUULHGRXWE\FKLOGUHQZLWKRXWVXSHUYLVLRQ
z
7KHSXPSPXVWQRWEHXVHGRURSHUDWHGXQGHUDQ\FLUFXPVWDQFHVZKHQWKHUHDUH
SHRSOHLQWKHVDPHZDWHU
z
8QGHUFHUWDLQFLUXPVWDQFHVLWLVSRVVLEOHWKDWFRQWDPLQDWLRQRIZDWHULVFDXVHG
E\OHDNDJH
THE MANUFACTURER EXPLAINS:
z
7RWDNHRYHUQRUHVSRQVLELOLW\LQWKHFDVHRIDFFLGHQWVRUGDPDJHVRQWKHEDVLVRIFDUHOHVV
QHVVRUGLVUHJDUGWRWKHLQVWUXFWLRQVLQWKLVERRN
z
7RUHMHFWHYHU\UHVSRQVLELOLW\IRUWKHGDPDJHVZKLFKRULJLQDWHIURPWKHLPSURSHUXVHRIWKHSXPS
9. GUARANTEE REGULATIONS
)RUDOOPDQXIDFWXULQJDQGPDWHULDOGHIHFWVWKHVWDWXWRU\ZDUUDQW\DSSOLHV,QWKHVHFDVHVZH
WDNHWKHUHSODFHPHQWRUUHSDLURIWKHSXPS6KLSSLQJFRVWVVKDOOEHERUQHE\RXUFRPSDQ\
H[FHSWDVUHTXLUHGE\ODZ3OHDVHUHSRUWWKHZDUUDQW\RQRXUVHUYLFHSODWIRUPKWWSZZZSUR¿
SXPSHGHVHUYLFHSKS:HZLOOLQIRUP\RXKRZWRSURFHHGZLWKFDVHUHODWHG5HWXUQVSOHDVH
VXI¿FLHQWSRVWDJH8QIRUWXQDWHO\QRWSUHSDLGUHWXUQVFDQQRWEHDFFHSWHGEHFDXVHWKH\DUH
¿OWHUHGRXWEHIRUHGHOLYHU\2XUVHUYLFHZHSURYLGHLQ*HUPDQ\
7KHZDUUDQW\GRHVQRWFRYHU
z
,PSURSHULQVWDOODWLRQVHOILQVWDOODWLRQXQDXWKRUL]HGSHUVRQV
z
0DWHULDOZHDUVHDOLQJULQJVLPSHOOHUZKHHOVLPSHOOHUFKDPEHUV
z
8QMXVWL¿HGLQWHUYHQWLRQVRUFKDQJHVLQWKHSXPS
z
'DPDJHVE\VHOIIDXOW
z
Improper servicing and improper use
z
'5<5811,*$OVRSDUWLDOO\RIWKHSXPS
Moreover, we give no damage compensation for secondary damages!
4 English
English 5
6. INSTALLATION SCHEME
7KHLQVWDOODWLRQPXVWEHFDUULHGRXWDVVKRZQLQ)LJD:HUHFRPPHQGWKHLQVWDOODWLRQRID
SUHVVXUHVZLWFK)LJEZKLFKPRQLWRUVWKHIXQFWLRQRIWKHSXPSDQGSURWHFWVLWIURPGDPDJH
Towing rope
Zugseil
Pressure switch
Druckschalter
Flexible hose
Panzerschlauch
Switch box
Schalterbox
Flexible hose
Panzerschlauch
Towing rope
Zugseil
Switch box
Schalter-Box
)LJD
)LJE
The pressure switch
shown in the picture is not
included.
A collection of powerful
pressure switches can be
found on our website:
http://www.profi-pumpe.de