Industrial Personal Computer Connections
100
The following figure shows the USB cable wiring:
Notes:
1. The following table gives the Non-incendive Circuit Parameters:
The Entity Concept allows interconnection of non-incendive apparatus with
associated apparatus – not specifically examined combinations – as a system when
the approved values of V
oc
(or U
o
) and I
sc
(or I
o
) for the associated apparatus are
less than or equal to Vmax (U
i
) and Imax (I
i
) for the non-incendive apparatus, and
the approved values of C
a
(C
o
) and L
a
(L
o
) for the associated apparatus are greater
than or equal to C
i
+ C
cable
and L
i
+ L
cable
, respectively, for the non-incendive field
wiring apparatus.
2. Associated Non-incendive Field Wiring Apparatus shall satisfy the following:
3. If the electrical parameters of the cable are unknown, the following values may be
used:
C
cable
= 196.85 pF/m (60 pF/ft)
L
cable
= 0.656
H/m (0.20
H/ft)
4. Wiring methods must be in accordance with the electrical code of the country in
use.
The Industrial Personal Computer must be installed in an enclosure. If installed in a
Class I, Division 2 Location, the enclosure must be capable of accepting one or
more Division 2 wiring methods.
Circuit Parameters
USB ports 1 and 3 USB ports 2 and 4 USB port 5
Open-circuit voltage = V
oc
5.066 V
5.26 V
5.089 V
Short-circuit current = I
sc
1320 mA
830 mA
1322 mA
Associated
capacitance = C
a
20
F
20
F
20 µF
Associated inductance = L
a
16.8
H
16.8
H
16.8 µH
Industrial Personal Computer
-
Associated Non-incendive Field Wiring
Apparatus (Mouse, Keyboard)
V
oc
I
sc
C
a
L
a
V
max
I
max
C
i
+ C
cable
L
i
+ L
cable
Summary of Contents for PS-4700 Series
Page 1: ...PS 4700 4800 Series User Manual Atom N270 Core 2 Duo P8400 Pre installed Model...
Page 14: ...General Overview 14...
Page 62: ...Characteristics 62...
Page 86: ...Implementation 86...
Page 120: ...Configuration of the BIOS 120...
Page 138: ...Installation 138...
Page 160: ...Appendices 160...
Page 164: ...After sales service 164...