background image

8

ENGLISH LANGUAGE
SAFETY AND PRECAUTIONS

• 

 

CAUTION:

 before using this product read carefully the following safety instruc  ons. Take a look of this manual en  rely and preserve it for 

future reference.
  When using any electric product, basic precau  ons should always be taken, including the following:
–  To reduce the risk, close supervision is necessary when the product is used near children.
–  Protect the apparatus from atmospheric agents and keep it away from water, rain and high humidity places.
–  This product should be site away from heat sources such as radiators, lamps and any other device that generate heat. 
–  Care should be taken so that objects and liquids do not go inside the product.
–  The product should be connected to a power supply mains line only of the type described on the opera  ng instruc  ons or as marked on the 
product. Connect the apparatus to a power supply using only power cord included making always sure it is in good condi  ons.
– 

 

WARNING:

 The mains plug is used as disconnect device, the disconnect device shall remain readily operable.

–  Power supply cord should be unplugged from the outlet during strong thunderstorm or when le   unused for a long period of   me.
–  Do not place objects on the product’s power cord or place it in a posi  on where anyone could trip over, walk on or roll anything over it. Do not 
allow the product to rest on or to be installed over power cords of any type. Improper installa  ons of this type create the possibility of 

fi

 re hazard 

and/or personal injury.

IN CASE OF FAULT

•  In case of fault or maintenance this product should be inspected only by quali

fi

 ed service personnel when:

–  There is a 

fl

 aw either in the connec  ons or in the supplied connec  ng cables.

–  Liquids have spilled inside the product.
–  The product has fallen and been damaged.
–  The product does not appear to operate normally or exhibits a marked change in performance.
–  The product has been lost liquids or gases or the enclosure is damaged.
•  Do not operate on the product, it has no user-serviceable parts inside, refer servicing to an authorized maintenance centre.

CE CONFORMITY

•  Proel products comply with direc  ve 2004/108/EC (EMC), as stated in EN 55013 standard and with direc  ve 2006/95/CE (LVD), as stated in EN 
60065 standard.
•  Under the EM disturbance, the ra  o of signal-noise will be changed above 10dB.

PACKAGING, SHIPPING AND COMPLAINT

•  This unit package has been submi  ed to ISTA 1A integrity tests. We suggest you control the unit condi  ons immediately a  er unpacking it.
•  If any damage is found, immediately advise the dealer. Keep all unit packaging parts to allow inspec  on.
•  Proel is not responsible for any damage that occurs during shipment.
•  Products are sold “delivered ex warehouse” and shipment is at charge and risk of the buyer.
•  Possible damages to unit should be immediately no  

fi

 ed to forwarder. Each complaint for package tampered with should be done within eight 

days from product receipt.

WARRANTY AND PRODUCTS RETURN

•  Proel products have opera  ng warranty and comply their speci

fi

 ca  ons, as stated by manufacturer.

•  Proel warrants all materials, workmanship and proper opera  on of this product for a period of two years from the original date of purchase. If 
any defects are found in the materials or workmanship or if the product fails to func  on properly during the applicable warranty period, the owner 
should inform about these defects the dealer or the distributor, providing receipt or invoice of date of purchase and defect detailed descrip  on. 
This warranty does not extend to damage resul  ng from improper installa  on, misuse, neglect or abuse. Proel S.p.A. will verify damage on returned 
units, and when the unit has been properly used and warranty is s  ll valid, then the unit will be replaced or repaired. Proel S.p.A. is not responsible 
for any "direct damage" or "indirect damage" caused by product defec  veness.

INSTALLATION AND DISCLAIMER

•  Proel products have been expressly designed for audio applica  on, with signals in audio range (20Hz to 20kHz). Proel has no liability for damages 
caused in case of lack of maintenance, modi

fi

 ca  ons, improper use or improper installa  on non-applying safety instruc  ons.

•  Proel S.p.A. reserves the right to change these speci

fi

 ca  ons at any   me without no  ce.

•  Proel S.p.A. declines any liability for damages to objects or persons caused by lacks of maintenance, improper use, installa  on not performed 
with safety precau  ons and at the state of the art.

POWER SUPPLY AND MAINTENANCE

•  Clean only with dry cloth.
• Before connec  ng the product to the mains outlet make certain that the mains line voltage matches that shown on the rear of the product, a 
tolerance of up to ±10% is acceptable.

Summary of Contents for M602FX

Page 1: ...M602FX 6 CH 2 BUS MIXER USER MANUAL MANUALE D USO ...

Page 2: ...may be of sufficient magnitude to cons tute a risk of electric shock to persons The exclama on point within an equilateral triangle is intended to alert the user to the presence of important opera ng and maintenance servicing instruc ons in the literature accompanying the appliance The informa on contained in this publica on has been carefully prepared and checked However no responsibility will be t...

Page 3: ...TION AND DISCLAIMER 8 POWER SUPPLY AND MAINTENANCE 8 GENERAL INFORMATION 9 OPERATING INSTRUCTIONS FIG 1 2 9 INDICE SPECIFICHE TECNICHE 4 DIMENSIONI MECCANICHE 5 CONNESSIONI FIG 1 5 PANNELLO DI CONTROLLO FIG 2 6 ESEMPIO CONFIGURAZIONE 7 LINGUA ITALIANA 14 AVVERTENZE PER LA SICUREZZA 14 IN CASO DI GUASTO 14 CONFORMITÀ CE 14 IMBALLAGGIO TRASPORTO E RECLAMI 14 GARANZIE E RESI 14 INSTALLAZIONE E LIMITA...

Page 4: ... TRK nom out level 0 dBu Unbalanced Rca Livello nom 2 TRK OUT 0 dBu Rca Sbilanciato 2 TRK nom in level 0 dBu Unbalanced Rca Livello nom 2 TRK IN 0 dBu Rca Sbilanciato PHONES min impedance 32 ohm Stereo Jack Impedenza min PHONES 32 ohm Jack Stereo PHONES max out level 2x 193 mW Livello max PHONES 2x 193 mW DIGITAL EFFECT PROCESSOR PROFEX DIGITAL EFFECT PROCESSOR PROFEX Presets 256 16 presets x 16 v...

Page 5: ... to make cable from balanced to unbalanced PHONES Jack stereo PHONES Stereo Jack Ɵp leŌ ring right sleeve ground 2TRK IN OUT Jack sbilanciato 2TRK IN OUT Jack unbalanced ground hot cold nota conneƩere insieme cold e ground per cavi da bilanciato a sbilanciato note connect both cold and ground to make cable from balanced to unbalanced MIC INPUT XLR bilanciato maschio MIC INPUT Balanced male XLR gro...

Page 6: ...6 CONTROL PANEL FIG 2 PANNELLO DI CONTROLLO FIG 2 18 17 9 2 4 5 7 10 12 19 8 1 3 6 11 14 13 16 22 21 26 27 15 20 31 33 34 29 37 38 39 23 32 36 30 25 35 24 28 ...

Page 7: ...IC SAX MIC ACOUSTIC GUITAR with amplified pickup HEADPHONES FLASH5A desktop monitors or other AUDIO SYSTEM PERSONAL COMPUTER WITH AUDIO IN OUT CAPABILITY KEYBOARD FLASH12HDA acƟve processed speaker or other AUDIO SYSTEM WEDGE MONITOR or other AUDIO SYSTEM ...

Page 8: ...0065 standard Under the EM disturbance the ra o of signal noise will be changed above 10dB PACKAGING SHIPPING AND COMPLAINT This unit package has been submi ed to ISTA 1A integrity tests We suggest you control the unit condi ons immediately a er unpacking it If any damage is found immediately advise the dealer Keep all unit packaging parts to allow inspec on Proel is not responsible for any damage...

Page 9: ...R input from almost any type of microphone or a line JACK input which accepts a balanced or unbalanced line level input signal from almost any source If the LINE R jack is not inserted this channel operate like a MONO channel with this input as a single signal source Wiring is the same of previous paragraphs 4 LINE R Input This is a 6 3mm jack connector which accepts a balanced or unbalanced line ...

Page 10: ...he preset and the varia on selected in the PROFEX effect are kept in the memory even if you turn off the mixer PRESET DESCRIPTION p 1 BRIGHT HALL This type of reverb simulates the ambience of a grand concert hall Dense smooth reverb with long pre delay and a lot of high frequency reflec ons Works well with vocals electric and acous c guitars strings The VARIATIONS vary the decay me and the hall size...

Page 11: ...an be turned on off also by means of a footswitch connected to the FX MUTE jack socket 18 PEAK detector This LED shows 2 condi ons always lighted signals that the effect is MUTED flashing signals a too high input level near to the overload of the effect input stage In this case reduce the level of the AUX FX sends The PEAK LED flashes when the effect input signal is near to the A D satura on point of ...

Page 12: ...s are made of two columns of of eight LEDs with three colours to indicate different ranges of signal level green shows the normal opera ve level of the signal from 30 to 6 dBu yellow shows the nominal opera ve level of the signal from 0 to 6 dBu red shows a high signal level near 20 dBu CLIP level 34 PHONES stereo jack output STEREO JACK connector for the headphones output only stereo headphones wi...

Page 13: ...13 ...

Page 14: ...ard EN 55013 ed alla dire va 2006 95 CE LVD secondo lo standard EN 60065 Se so oposto a disturbi EM il rapporto segnale rumore può essere superiore a 10dB IMBALLAGGIO TRASPORTO E RECLAMI L imballo è stato so oposto a test di integrità secondo la procedura ISTA 1A Si raccomanda di controllare il prodo o subito dopo l apertura dell imballo Se vengono riscontra danni informare immediatamente il riven...

Page 15: ...n un conne ore XLR un segnale microfonico bilanciato da ogni po di microfono oppure con un conne ore JACK di acce are un segnale di livello linea bilanciato o sbilanciato da ogni po di sorgente Se il jack LINE R non è inserito questo canale opera come un canale MONO con questo ingresso come sorgente unica I terminali sono gli stessi del precedente capitolo 4 LINE R ingresso linea R È un conne ore ...

Page 16: ... LEVEL 24 fino ad udire l effe o regolare i controlli AUX 9 17 prima della saturazione del segnale indicata dal LED di picco 23 regolare nuovamente la manopola FX LEVEL per combinare il segnale dell effe o con il segnale naturale NOTA il PROFEX man ene in memoria il preset e la variazione seleziona anche se il mixer viene spento DESCRIZIONE DEI PRESET p 1 BRIGHT HALL Questo po di riverbero simula l ...

Page 17: ...15 premendo almeno due volte questo pulsante è possibile impostare il tempo di ripe zione desiderato secondo il ritmo musicale e visualizzato dal LED 17 MUTE pulsante per silenziare l effe o Premere questo pulsante se si vuole silenziare il segnale uscente dall effe o interno al MAIN MIX NOTA l effe o può anche essere acceso o spento tramite un pedale connesso alla presa jack FX MUTE 18 PEAK rilevato...

Page 18: ...ata che può inviare il segnale su una linea bilanciata con o senza la phantom power a va Pertanto M602FX può essere u lizzato come una combinazione mixer DI box per inviare il segnale a un mixer principale 33 L R LEVEL METERS indicatori di livello Gli indicatori di livello sono cos tui di due colonne di o o led di tre colori che indicano diversi livelli opera vi verde normale livello opera vo del ...

Page 19: ...19 ...

Page 20: ...REV 50 12 CODE 96MAN0062 PROEL S p A World Headquarter Via alla Ruenia 37 43 64027 Sant Omero TE ITALY Tel 39 0861 81241 Fax 39 0861 887862 www proel com ...

Reviews: