SETUP AND RACK MOUNTING (FIG. 1)

INSTALLAZIONE A RACK (FIG. 1)

FIG.1

LOUDSPEAKER CABLE

CAVO ALTOPARLANTE

ENGLISH: 

Loudspeaker Line Losses

 (maximum permissible line lengths for 0.5dB losses, voltage or spl)

ITALIANO: 

Perdite di collegamento linee Altoparlanti

 (massima lunghezza possibile per perdite inferiori a 0.5dB, tensione o spl)

4 ohm load

8 ohm load

Wire section data

PROEL recommended cables

feet meter feet meter

mm²

AWG

2 wires

4 wires

2 wires Fire-resistant for fixed 

installation

2  wires  Fire-resistant 

with shielding

75

25

150 50

4.0

12

HPC624BK

HPC644

HPC624FT(black) HPC624HT (blue)

HPC624FRS (green)

50

17.5

100 35

2.0

14

HPC620BK

HPC640BK

HPC620FT(black) HPC620HT (blue)

HPC620FRS (green)

30

10

60

20

1.5

16

HPC610BK

HPC610FT(black) HPC610HT (blue)

HPC610FRS (green)

20

7.5

40

15

1.0

18

HPC600

this is a short extraction of the wide assortment of cables available from PROEL, please visit our website at www.proel.com

COLD AIR

FRONTALE

8U OPEN RACK

10U closed RACK

RACK aperto 8U

RACK chiuso 10U

POSTERIORE

FRONT

REAR

FRONTALE

POSTERIORE (chiuso)

FRONT

REAR (closed)

ARIA FREDDA

COLD AIR

ARIA FREDDA

HOT AIR

HOT AIR

ARIA CALDA

ARIA CALDA

15 cm

6 inch

RECOMMENDED INSTALLATION

INSTALLAZIONE RACCOMANDATA

EVENTUAL INSTALLATION WITH CLOSED BACK

EVENTUALE INSTALLAZIONE CON RETRO CHIUSO

Summary of Contents for DPX1200PFC

Page 1: ...DPX1200PFC DPX1700PFC DPX2500PFC 2 channel power amplifiers USER MANUAL MANUALE D USO...

Page 2: ...constitute a risk of electric shock to persons The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instr...

Page 3: ...Ingresso 20 Kohm bilanciato 10 Kohm sbilanciato Input Connectors XLR F INPUT XLR M LINK Connettori Ingresso XLR F INPUT XLR M LINK Output Connectors NL4 Speakon Connettori Uscita NL4 Speakon Controls...

Page 4: ...12 HPC624BK HPC644 HPC624FT black HPC624HT blue HPC624FRS green 50 17 5 100 35 2 0 14 HPC620BK HPC640BK HPC620FT black HPC620HT blue HPC620FRS green 30 10 60 20 1 5 16 HPC610BK HPC610FT black HPC610H...

Page 5: ...2 bridge negative 2 channel 2 positive canale 2 positivo 2 LINK rilancio ingresso XLR bilanciato femmina LINK Balanced female XLR ground hot cold n c INPUT ingresso Jack bilanciato INPUT Jack balanced...

Page 6: ...6 FRONT PANEL FIG 4 PANNELLO FRONTALE FIG 4 DIMENSIONS FIG 3 DIMENSIONI FIG 3 1 2 2 3 3 4 4 5 5 6 6 7 8 44 0 cm 17 3 8 81 cm 3 47 48 0 cm 19 0 23 3 cm 9 2 2 2 cm 0 8...

Page 7: ...7 REAR PANEL FIG 5 PANNELLO POSTERIORE FIG 5 9 10 12 9 10 11 14 13 15 16...

Page 8: ...et as PARALLEL for 2 channel pairs driven from 1 audio channels 1 1 R 1 1 8 minimum set as BRIDGE for doubled power for 1 loudspeakers driven from both audio channels and set as HPF if used in combina...

Page 9: ...ofer driven from both audio channels and set as BI AMP for 100Hz 24 dB oct low pass lter 1 2 IMPORTANT wire as speci ed above 1 1 mid high speaker 4 minimum subwoofer 4 minimum set as PARALLEL for 2 c...

Page 10: ...ng high sound pressure levels use hearing protectors while the equipment is in operation Ear plugs or protectors in the ear canals or over the ears must be worn when operating the equipment in order t...

Page 11: ...r repaired Proel S p A is not responsible for any direct damage or indirect damage caused by product defectiveness INSTALLATION AND DISCLAIMER Proel products have been expressly designed for audio app...

Page 12: ...n and AC power is available 3 Channel LEVEL Control Rotary level control in STEREO and PARALLEL operation it attenuates the level of the signal sent to the correspondent channel of the amplifier while...

Page 13: ...ilter configurations HPF enables a 100Hz LR 24dB Oct High Pass Filter for both channels 1 and 2 this a useful feature for SAT TOP SPEAKERS or STAGE MONITORS see EXAMPLE B NOTE when using HPF in combin...

Page 14: ...ik Speakon NL4FX connector wired in this way PIN 1 connected to POSITIVE output of Channel 2 PIN 1 connected to NEGATIVE output of Channel 2 PIN 2 and 2 NOT connected This is the amplified output of t...

Page 15: ...gerimento viene riportata la tabella dei tempi massimi di esposizione giornaliera al rumore al fine di evitare perdite di udito fonte della tabella l ente per la salute degli Stati Uniti OSHA Si fa pr...

Page 16: ...i esclusivamente ad un utilizzo specifico di tipo sonoro segnali di ingresso di tipo audio 20Hz 20kHz Proel declina ogni responsabilit per danni a terzi causati da mancata manutenzione manomissioni us...

Page 17: ...verde quando acceso indica che l amplificatore stato acceso e l alimentazione AC disponibile 3 Controllo di Livello del Canale Controllo di livello rotativo in modalit STEREO e PARALLEL attenua il li...

Page 18: ...olito cio 1 per il positivo e 1 per il negativo 12 HPF BI AMP FLAT Questo selettore permette la selezione di una delle seguenti configurazioni di filtraggio HPF abilita un filtro passa alto a 100Hz LR...

Page 19: ...usati per microfoni strumenti e apparecchiature audio in generale 14 Uscita SPEAKON Channel 2 o 4 Accetta un connettore Neutrik Speakon NL4FX femmina collegato come segue PIN 1 collegato all uscita PO...

Page 20: ...REV 36 18 CODE 96MAN0137 PROEL S p A World Headquarter Via alla Ruenia 37 43 64027 Sant Omero TE ITALY Tel 39 0861 81241 Fax 39 0861 887862 www proel com...

Reviews: