TRI-1R and TRI-P-1R Series 

Modbus / BACnet / Analogue 

Touchscreen Room Interfaces

The TRI-1R series Modbus / BACnet / Analogue Touchscreen 
Room Interfaces provide modern looking thin profile user interface 
and I/O-module for flush mounting in room spaces.

The TRI series interfaces have attractive 3.5" backlit touchscreen 
with smart designer interface. TRI-P-1R/TRI-3A versions have 
7-day time clock to provide network clock facility.

The MOD models have built-in Modbus RTU communications and 
the BAC models provide BACnet MS/TP communications. The 
analogue versions can be used with BMS 0-10Vdc input cards.

Features

• 24VAC/DC Power Supply
• 3.5" Inch Backlit Touchscreen Display
• BACnet and Modbus Communication Models, Analogue Version
• P-Versions have 7 Day and 5+2 Day Schedule
• Flush Mounting in the UK, EURO and US Wall Mounting Box
• Attractive Modern Designer Look

• Built-In Temperature Sensor
• 2 x Remote NTC10 Sensor Inputs
• 250Vac Switched Network Relay (TRI-1R)
• 3 x 0-10Vdc Outputs (TRI-3A) 
• Digital Input for Overrides / Measuremen
• Modbus Models integrate with Produal CU Control Units 

Designed for Room Control Applications

Product sheet   

6001TRI

Type 

TRI

O rdering   guide

Type

0

1

2

3

4

5

6

0

Touchscreen room units

6001

0

1

Device type

Room unit, 2RI, 1DI, 1RO

TRI-1R

6

Room unit, 2RI, 1DI, 1RO, 7-days schedule

TRI-P-1R

7

Room unit, 2RI, 1DI, 3AO

TRI-3A

8

2

Communication

No Communication (only TRI-3A)

A

Modbus

-MOD

M

BACnet

-BAC

B

3

Power supply

24 Vac/dc

-24

2

12 Vdc (only TRI-1R)

-12

1

4

Additional measurements

0

Relative humidity

-RH

1

CO

2

-CO2

2

Relative humidity and CO

2

-RH-CO2

3

5

Reserved

0

6

Body colour

Chrome

0

White (RAL 9010)

-W

W

Black (RAL 8022)

-B

B

No additional measurement

Summary of Contents for TRI-1R Series

Page 1: ...dbus Communication Models Analogue Version P Versions have 7 Day and 5 2 Day Schedule Flush Mounting in the UK EURO and US Wall Mounting Box Attractive Modern Designer Look Built In Temperature Sensor 2 x Remote NTC10 Sensor Inputs 250Vac Switched Network Relay TRI 1R 3 x 0 10Vdc Outputs TRI 3A Digital Input for Overrides Measuremen Modbus Models integrate with Produal CU Control Units Designed fo...

Page 2: ...via Touchscreen Communication 9k6 19k2 38k4 57k6 76k8 Baud Parity None Even Odd 1 or 2 Stop Bits adjustable through Touchscreen BACnet BAC models Protocol BACnet MS TP Interface RS485 maximum 63 devices segment MAC Addressing 0 to 127 via Touchscreen Device ID Default 651000 MAC Address User Configured Communication 9k6 19k2 38k4 57k6 76k8 Baud Parity None Even Odd 1 or 2 Stop Bits Connections Ter...

Page 3: ...Contact 24V 24Vac dc Supply 0V 0V Supply Rin1 Remote NTC10 Temperature Sensor Input 1 Rin2 Remote NTC10 Temperature Sensor Input 2 Din Volt Free Digital Input Contact 485A Modbus BACnet MS TP RS485 A Connection 485B Modbus BACnet MS TP RS485 B Connection G0 0V Common CONN DESCRIPTION Y1 0 10Vdc Analogue Output 1 default fan speed Y2 0 10Vdc Analogue Output 2 default setpoint Y3 0 10Vdc Analogue Ou...

Page 4: ...WITH FAN SPEED 21 5 C Room 20 1 C A CONTROL MODE AUTO HEATING COOLING FAN VENTILATION FAN The TRI 1R room interface home screen has four touch sensitive areas that allow the system settings to be altered All parameter values are available as Modbus BACnet network variables Fan speed and setpoint are available as 0 10Vdc outputs with TRI 3A UP and DOWN arrows to alter the current target temperature...

Page 5: ...splayed on the screen Note If all sensor displays are Disabled the ACTION CIRCLE displays the last drawn image Setpoint Mode Inside the large circle on the HOME SCREEN the TRI 1R TRI 3A shows the target setpoint value As default the units are in temperature Celcius Fahrenheit It is possible to change the units to percentage to display the target values for percentage based control or to show tempe...

Page 6: ...yed here only if OFF icon has been enabled and the PARTY BOOST button has also been enabled LOCK icon is used to lock the device Number of different lock modes options exist CLEANING icon is used to enable timed cleaning mode CLOCK icon is used to set the time TRI P 1R only CALENDAR icon is used to enter the programming screens to set the switching times the tem perature targets TRI P 1R only COG ...

Page 7: ...0 Speed 1 Speed 2 Speed 0 Speed 3 A Auto SPEED SET BY NETWORK To set the fan speed or the line bar to a position touch the line bar fan icon area and the line icon and network variable is set according the configuration e g 1 step 2 step etc The options for the FAN MANUAL CONTROL operating the FAN speed manually are DISABLED Default 1 STEP fan speed rotates between OFF and 6 segments 2 STEP fan sp...

Page 8: ...Speed Night parameter value When returning from night the speed goes to 100 if fan mode is set to any of the auto options If the fan mode is configured for non auto options then the fan speed returns to speed 1 Operating Mode Icon The interface unit has Operating Mode icon that allows the unit operating mode to be set network variable 21 5 C Room 23 8 C CONTROL MODE PRESS ING ICON ROTATES BETWEEN ...

Page 9: ...sible default ENABLED OFF Icon is displayed in the HOME SCREEN in the FUNCTION BASED ICON area if the PARTY MODE has not been enabled Otherwise it is displayed in the FURTHER SET TINGS SCREEN Night Mode Digital Input Override The TRI 3A 1R can be switched to Night mode via the Digital Input In the Night mode the target display is dimmed like in OFF mode and the Fan Speed is set as per the Fan Nigh...

Page 10: ... screen 21 5 C Room 20 1 C LIGHTS STATUS AND ON OFF SWITCH LIGHTS ON LIGHTS OFF A C STATUS AND ON OFF SWITCH A C ON A C OFF When touching the buttons the Lights and or AC Icon are either swithed ON or OFF The status of the buttons is available over the network It is also possible to override the Icons ON or OFF over the network The buttons are enabled through the Maintenance Mode in the Display se...

Page 11: ...or 2 Res2 fault when activated not connected Built in sensor fault Digital Contact Fault Time Lost TRI P 1R only Note If the sensor source has been set to Network then the alarm is inhibited External Sensor RI1 and RI2 Inputs A remote NTC10k3 sensor can be connected to the RI1 and RI2 input and used for the monitoring purposes The measurement is always available over the communications network in ...

Page 12: ...te humidity sensor for room space humidity measurement The humidity reading is displayed inside the SMALL ACTION CIRCLE display as default enabled option to disable through configuration pages With MOD BAC models the humidity reading is available over the communication network as a network variable With TRI 3A models the humidity measurement can be sent to any of the analogue 0 10Vdc outputs Y1 Y2...

Page 13: ... SWITCHING TIME TOUCH TARGET TO SELECT SWITCH ING TARGET 7 4 1 0 8 9 5 6 2 3 Esc Enter Del 7 4 1 0 ENTER SELECTED PERIOD SWITCHING TIME Monday Set Switching Time 07 40 0 12 24 18 6 Mon On Off On 06 30 Off 13 00 On 18 00 Off 22 30 Off 23 30 Language Selection The TRI user pages can be displayed in different languages by selecting the language from the System Configuration pages By enabling the Show...

Page 14: ...work is always active 0 Hardware Built In Sensor Default 1 Network Digital Input Mode Digital Input Operation status monitoring over the network is active for all modes 0 Disabled no TRI effect 1 Close for ECO 2 Open for ECO 3 Close for OFF 4 Open for OFF 5 DI Contact Alarm 6 Network 7 Close for Night 8 Disabled Digital Input Delay Digital Input Delay Timer transition from active to non active 0 7...

Page 15: ...or 1 9 Sensor 2 10 Sensor 3 Default OPERATING MODES Parameter Name Description Range DISPLAY Parameter Name Description Range Brightness Backlight Brightness 0 20 default 5 Enable Lights Enable Lights Icon Network Variable 0 Disabled default 1 Enabled Enable AC Enable AC Icon Network Variable 0 Disabled default 1 Enabled Fan Speed Display Enable Fan Speed Display and Line Bar Icon Display 0 Disabl...

Page 16: ...tion Range SYSTEM Parameter Name Description Range Address Modbus Address Only Modbus versions BACnet MAC Address Only BACnet versions 0 247 Default 1 0 127 Default 1 Baud Rate Modbus BACnet Baud Rate 0 9600 Default 1 19200 2 38400 3 57600 4 76800 5 115200 Parity Parity 0 None Default 1 Odd 2 Even Stop Bits Stop Bits 0 1 Stop Bit Default 1 2 Stop Bits Device ID Only BACnet versions BACnet Device I...

Page 17: ...s to be entered Register Parameter Description Data Type Raw Data Range FUNCTION CODE 01 READ COILS FUNCTION CODE 05 WRITE SINGLE COIL FUNCTION CODE 15 WRITE MULTIPLE COILS 100 Off Mode Override last transition commands 0 1 Off On 101 ECO Mode Override last transition commands 0 1 Off On 102 Show Frost Icon 0 1 Off On 103 Boost Override Override Boost Icon 0 1 Off On FUNCTION CODE 02 READ DISCRETE...

Page 18: ...ect 102 Sensor 3 Source Unsigned 16 0 1 0 Buillt In Sensor Default 1 Network Sensor 103 Sensor 3 Network Temperature Signed 16 580 1220 58 0 122 0 C F Default 0 0 104 Minimum Setpoint Unsigned 16 0 990 0 0 99 9 C F Default 14 C 105 Maximum Setpoint Unsigned 16 0 990 0 0 99 9 C F Default 30 C 106 Colour Ring Mode Unsigned 16 0 10 0 White 1 Red 2 Blue 3 Green 4 Orange 5 Yellow 6 Magenta 7 Cyan 8 Sen...

Page 19: ...tion 125 Party Mode Boost Time Unsigned 16 0 480 0 480 minutes Default 0 0 Disabled 126 Backlight Brightness Unsigned 16 0 20 0 20 default 5 127 Relay Control Mode Control Controlled by the time schedule party mode boost Network Controlled by network Unsigned 16 0 1 0 Control Normally Open Default 1 Control Normally Closed 2 Network 128 Lock Mode Password Unsigned 16 0 9999 0000 9999 129 Maintenan...

Page 20: ... 0 59 146 Current Day P version Unsigned 16 1 31 1 31 147 Current Month P version Unsigned 16 1 12 1 12 148 Current Year P version Unsigned 16 2015 2099 2015 2099 149 Current Hour Update Register P version Unsigned 16 0 23 0 23 150 Current Minute Update Register P version Unsigned 16 0 59 0 59 151 Current Day Update Register P version Unsigned 16 1 31 1 31 152 Current Month Update Register P versi...

Page 21: ...Tuesday Switching Time 4 Target Unsigned 16 0 1 0 1 Default 0 219 Tuesday Switching Time 5 Target Unsigned 16 0 1 0 1 Default 0 220 Wednesday Switching Time 1 Unsigned 16 0 2400 0 2400 Default 0600 221 Wednesday Switching Time 2 Unsigned 16 0 2400 0 2400 Default 1000 222 Wednesday Switching Time 3 Unsigned 16 0 2400 0 2400 Default 1300 223 Wednesday Switching Time 4 Unsigned 16 0 2400 0 2400 Defau...

Page 22: ...witching Time 1 Unsigned 16 0 2400 0 2400 Default 0600 261 Sunday Switching Time 2 Unsigned 16 0 2400 0 2400 Default 1000 262 Sunday Switching Time 3 Unsigned 16 0 2400 0 2400 Default 1300 263 Sunday Switching Time 4 Unsigned 16 0 2400 0 2400 Default 1700 264 Sunday Switching Time 4 Unsigned 16 0 2400 0 2400 Default 1700 265 Sunday Switching Time 1 Target Unsigned 16 0 1 0 1 Default 0 266 Sunday S...

Page 23: ...DE 3 ECO ECO MODDE 4 CO2 Sensor Measurement Unsigned 16 0 5000 0 5000ppm 5 Humidity Measurement Unsigned 16 0 1000 0 100 0 rH FUNCTION CODE 03 READ HOLDING REGISTERS For Modicon Addressing Add 40 000 FUNCTION CODE 06 WRITE SINGLE HOLDING REGISTER FUNCTION CODE 16 WRITE MULTIPLE HOLDING REGISTERS 1 Setpoint Center Nominal Setpoint Unsigned 16 0 990 0 99 9 Default 21 0 C F 2 Setpoint Limits Sets the...

Page 24: ...V 1 Sensor 1 Temp AV 2 Sensor 2 Temp AV 3 Sensor 3 Temp AV 4 Brightness AV 5 Y1 Output AV 6 Y2 Output AV 7 Y3 Output Binary Input 5 BI 0 Digital Input DI1 BI 1 Boost Party Mode Status BI 2 Schedule Status only TRI P 1R BI 3 Time Lost only TRI P 1R BI 4 Auto Fan Status Binary Output 11 BO 0 Relay BO 1 OFF Status 1 BO 2 ECO Status 1 BO 3 Lights 2 BO 4 AC 2 BO 5 Lock 1 BO 6 Frost Icon BO 7 Non Volati...

Page 25: ...ct type and MAC address i e TRI_001 Object Type R Device System Status R STATUS_OPERATIONAL Vendor Name R Produal Oy Vendor Identifier 783 Model Name R TRI7 Protocol Version R 1 Protocol Revision R 10 Max APDU Length R 480 Segmentation Support R No APDU Timeout R 6000 ms Number APDu Retries R 3 MaxMaster R 127 Max_Info_Frames R 1 Database Revision R 0 Property Name ID Attributes Range Default Requ...

Page 26: ...d 0 Disabled default 1 Enabled 40117 Lock Mode Unsigned 0 Lock mode disabled default 1 On Off Boost workable only 2 Temp settings only available 3 All buttons disabled 40118 Show Temperature Unit Selection Icon Centigrade Fahrenheit Unsigned 0 Disabled default 1 Enabled 40119 Built In Sensor Calibration REAL 10 0 10 0 C F 40120 RI1 Sensor Calibration REAL 10 0 10 0 C F 40121 RI2 Sensor Calibration...

Page 27: ...he display Unsigned 40142 Sensor 2 Source Unsigned 0 RI1 1 Network Sensor Default 40159 Disable ECO Button User Cancel Unsigned 0 Enabled 1 Disabled 40160 CO2 Calibration REAL 500 500 ppm 40161 Y1 Output Mode Default Fan Unsigned 0 Network 1 Sensor1 RI1 2 Sensor2 RI2 3 Sensor3 Built In 4 Setpoint 5 Fan 6 Humidity 7 CO2 40162 Y2 Output Mode Default Setpoint Unsigned 40163 Y3 Output Mode Default Sen...

Page 28: ...1 93 28 5mm 1 22 20 5mm 0 81 28 5mm 1 22 With CO2 Sensor Fitted Standard Unit Dimensions Produal Oy Copyright 2020 Produal Oy All rights reserved 07 2020 PS 6001TRI 28 28 Web site www produal com Enquiries T 358 10 219 9100 E info produal fi NOTE Information is subject to change without prior notice ...

Reviews: