background image

 Page 4

WARNING
INHALATION HAZARD: Welding and Plasma 

Cutting Produce
TOXIC FUMES.

Exposure to welding or cutting exhaust fumes can increase 

the risk of developing certain cancers, such as cancer of 

the larynx and lung cancer. Also, some diseases that may 

be linked to exposure to welding or plasma cutting exhaust 

fumes are:
a. Early onset of Parkinson’s Disease
b. Heart disease
c. Ulcers
d. Damage to the reproductive organs 
e. Inflammation of the small intestine or stomach 
f. Kidney damage
g. Respiratory diseases such as emphysema, bronchitis, or 

pneumonia
Use natural or forced air ventilation and wear a respirator 

approved by NIOSH to protect against the fumes produced 

to reduce the risk of developing the above illnesses.
Avoid overexposure to fumes and gases. Always keep your 

head out of the fumes. Do not breathe the fumes. 

1. Use enough ventilation or exhaust, or both, to keep 

fumes and gases from your breathing zone and general 

area.

a. Where ventilation is questionable, have a qualified 

technician take an air sampling to determine the need for 

corrective measures. Use mechanical ventilation to improve 

air quality. If engineering controls are not feasible, use an 

approved respirator.
b. Work in a confined area only if it is well ventilated, or 

while wearing an air-supplied respirator.
c. Follow OSHA guidelines for Permissible Exposure Limits 

(PEL’s) for various fumes and gases.
d. Follow the American Conference of Governmental 

Industrial Hygienists recommendations for Threshold Limit 

Values (TLV’s) for fumes and gases.
e. Have a recognized specialist in Industrial Hygiene or 

Environmental Services check the operation and air quality 

and make recommendations for the specific welding or 

cutting situation.

2. Always keep hoses away from welding/cutting spot. 

Examine all hoses and cables for cuts, burns, or worn areas 

before each use. If any damaged areas are found, replace 

the hoses or cables immediately.
3. Read and understand all instructions and safety 

precautions as outlined in the manufacturer’s Manual for 

the material you will weld or cut.

1. Proper cylinder care.

 Secure cylinders to a cart, wall, or 

post, to prevent them from falling. All cylinders should be 

used and stored in an upright position. Never drop or strike 

a cylinder. Do not use cylinders that have been dented. 

Cylinder caps should be used when moving or storing 

cylinders. Empty cylinders should be kept in specified areas 

and clearly marked “empty.”

2. Never use oil or grease on any inlet connector, outlet 

connector, or cylinder valves.
3. Use only supplied Torch on this Inverter Air Plasma 

Cutter.

 Using components from other systems may cause 

personal injury and damage components within.
People with pacemakers should consult their physician(s) 

before using 1.  this product. Electromagnetic fields 

in close proximity to a heart pacemaker could cause 

interference to, or failure of the pacemaker.

2. USE PROPER EXTENSION CORD.

Make sure your extension cord is in good condition. 

When using an extension cord, be sure to use one heavy 

enough to carry the current your product will draw. An 

undersized cord will cause a drop in line voltage resulting 

in loss of power and overheating. We recommend that 

a 15amp extension cord be used with the 1.5mm

2

 cable. 

The following Toolex Industrial Extension Leads would be 

suitable 594530 10 metre, 594531 20 metre & 594532 30 

metre.

Summary of Contents for 511464

Page 1: ...or serious injury SAVE THESE INSTRUCTIONS Keep this manual for the safety warnings and precautions assembly operating inspection maintenance and cleaning procedures Write the product s serial number...

Page 2: ...If it still does not fit contact a qualified electrician to install a polarized outlet Do not change the plug in any way Double insulation eliminates the need for the three wire grounded power cord an...

Page 3: ...t eye injury and burns Wearing and using the approved personal safety clothing and safety devices reduce the risk for injury a Wear the approved safety impact eye goggles with a welding helmet featuri...

Page 4: ...l Hygiene or Environmental Services check the operation and air quality and make recommendations for the specific welding or cutting situation 2 Always keep hoses away from welding cutting spot Examin...

Page 5: ...means that it is easier to design into welding machine with different dynamic characteristics and it even can be adjusted for specialty to make arc softer or harder MMA welding machine has the follow...

Page 6: ...age V Output Current A Rated Input Current A Frequency hz Power Voltage V MODELS Parameters Weight kg Housing Protection Grade 345 x 230 x 235 450 x 300 x 305 330 x 290 x 250 22 1 24 4 20 140 20 180 2...

Page 7: ...clockwise and the earth clamp at the other terminal clamps the work piece 5 Please pay attention to the connecting polarity DC welding machine has two connecting ways positive connection and negative...

Page 8: ...Page 8 511464 Panel Instruction 511465 Panel Instruction 511466 Panel Instruction MODEL 511465 INVERTER MMA TIG 220i...

Page 9: ...precautions staring on page 1 and especially the section Specific Safety Rules starting on page 3 Put the metal to be welded on the metal weeding cutting table Ensure the metals to 1 be welded are cle...

Page 10: ...ess to the internal components of the unit remove screws from Main Body Cover The home user is strongly advised not to remove the tool covers and not to attempt any electronic repairs Any repairs must...

Page 11: ...electrode and causes droplets of the electrode to be passed from the electrode to the weld pool As the electrode melts the flux covering disintegrates giving off shielding gases that protect the weld...

Page 12: ...Line broken Check connection Fuse 10A is broken Change fuse Gas switch on back panel is broken when in normal working IGBT module rectifier bridge output diode or other components may damaged Check u...

Page 13: ...ble Earth Clamp 500892 511464 140i MMA TIG 511465 220i MMA TIG 511466 180i MMA TIG INCLUDED STANDARD ACCESSORIES 4m Cable Electrode Holder 500891 4m Cable Earth Clamp 500893 INCLUDED STANDARD ACCESSOR...