www.usaprocom.com
11
200044-01A
Figure 4 - Mounting Clearances as
Viewed From Front of Heater
INSTALLATION
2. Take out the bulb clip from the hardware
package and insert it into the square hole.
Insert the sensing bulb into the bulb clip
(see Figure 5).
FASTENING HEATER TO WALL
Mounting Bracket
The mounting bracket is located on back panel
of heater (see Figure 6). It has been taped
there for shipping. Remove mounting bracket
from back panel.
Figure 6 - Mounting Bracket Location
Figure 5 - Moving Thermostat Sensing
Bulb
Removing Front Panel of Heater
1. Remove two screws near bottom corners
of lower front panel.
2. Pull bottom of lower front panel forward,
then down (see Figure 7).
Figure 7 - Removing Front Panel Of
Heater
Mounting Bracket
Pull
Out
Hole for Installing Clip
CEILING
36"
Minimum
6"
Minimum
From
Sides of
Heater
Left
Side
Right
Side
2" Minimum to Top Surface of Carpeting,
Tile or Other Combustible Material
FLOOR
LOCATING HEATER
This heater is designed to be mounted on a
wall. You can locate heater on the floor, away
from a wall. An optional floor mounting stand
is needed. See
Accessories
, page 30.
For convenience and efficiency, install heater:
1. Where there is easy access for operation,
inspection, and service.
2. In the coldest part of room.
An optional fan kit is available from your dealer
See
Accessories
, page 30. If planning to use
fan, locate heater near an electrical outlet.
INSTALLING THERMOSTAT
SENSING BULB (OPTIONAL)
1. Pull out the sensing bulb from the two clips
located in the shipping position according
to the direction as shown by the arrow.
There is no need to take out the two bulb
clips.