1.  Do not place Propane/LP supply tank(s) inside any structure. Propane/LP supply tank(s) must be placed 

outdoors. 

2.  This heater shall not be installed in a bedroom or bathroom. 
3.  Do not use this heater as a wood-burning heater. Use only the logs provided with the heater. 
4.  Do not add extra logs or ornaments such as pine cones, vermiculite, or rock wool. Using these added items 

can cause sooting. Do not add lava rock around base. Rock and debris could fall into the control area of heater. 
After servicing, always replace screen before operating heater. 

5.  Make sure the heater screen is in place before running the heater. 
6.  This  heater  is  designed  to  be  smokeless.  If  logs  ever  appear  to  smoke,  turn  off  heater  and  call  a  qualified 

service  person. 

Note:

  During  initial  operation,  slight  smoking  could  occur  due  to  log  curing  and  the  heater 

burning manufacturing residues.  

7.  To prevent the creation of soot, follow the instructions in 

Care and Maintenance

 (page 19). 

8.  Before  using  furniture  polish,  wax,  carpet  cleaner,  or  similar  products,  turn  heater  off.  If  heated,  the  vapors 

from these products may create a white powder residue within burner box or on adjacent walls or furniture. 

9.  This heater needs fresh air ventilation to run properly. This heater has an Oxygen Depletion Sensing (ODS) 

safety  shutoff  system.  The  ODS  shuts  down  the  heater  if  not  enough  fresh  air  is  available.  See 

Air  for 

Combustion and Ventilation

, pages 7 through 9. If heater keeps shutting off, see 

Troubleshooting

, pages 20 

through 22.  

10.  Do not run heater: 

 

Where flammable liquids or vapors are used or stored. 

 

Under dusty conditions. 

11.  Do not use this heater to cook food or burn paper or other objects. 
12.  Do  not  use  this  heater  if  any  part  has  been  under  water.    Immediately  call  a  qualified  service  technician  to 

inspect  the  room  heater  and  replace  any  part  of  the  control  system  and  any  gas  control  which  has  been 
underwater. 

13.  Turnoff and unplug heater and let cool before servicing. Only a qualified service person should service and 

repair heater. 

14.  Operating heater above elevations of 4,500 feet could cause pilot outage. 

15.  Do not operate heater if any log is broken. Do not operate heater if any log is chipped (dime-sized or larger). 

16.  To prevent performance problems, do not use a propane/LP fuel tank of less than 100 lbs capacity. 
 

QUALIFIED INSTALLING AGENCY 

Installation  and  replacement  of  gas  piping,  gas  utilization  equipment  or  accessories  and  repair  and  servicing  of 
equipment shall be performed only by a qualified agency. The term 

qualified agency

 means any individual, firm, 

corporation, or company that either in person or through a representative is engaged in and is responsible for:  

a)  The installation, testing, or replacements of gas piping or

 

b)

 

The connection, installation, testing, repair, or servicing of equipment; that is experienced in such work; that is 
familiar  with  all  precautions  required;  and  that  has  complied  with  all  the  requirement  of  the  authority  having 
jurisdiction.

 

 

Summary of Contents for EDP200T2-C

Page 1: ...y or the gas supplier INSTALLER DO NOT DISCARD THIS MANUAL LEAVE FOR HOMEOWNER S FUTURE REFERENCE WARNING IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY A FIRE MAY RESULT CAUSING PROPERTY D...

Page 2: ...ONS MODEL EDP200T2 C EDP200T2 O EDS200T2 HC Input Max 20 000 BTU Hr 19 000 BTU Hr 20 000 BTU Hr 19 000 BTU Hr Input Min 11 500 BTU Hr 16 500 BTU Hr 11 500 BTU Hr 16 500 BTU Hr Gas Type Natural LP Prop...

Page 3: ...It is your guide to safe and proper operation of this heater Make certain you read and understand all warnings Keep this manual for reference It is your guide to safe and proper operation of this hea...

Page 4: ...mbustion and Ventilation pages 7 through 9 If heater keeps shutting off see Troubleshooting pages 20 through 22 10 Do not run heater Where flammable liquids or vapors are used or stored Under dusty co...

Page 5: ...ts The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts Sellers of unvented propane or natural gas fired supplemental room heaters shall provide to ea...

Page 6: ...eater produces approximately one 1 ounce 30ml of water for every 1 000 BTU s 3KW s of gas input per hour Unvented room heaters are recommended as a supplemental heater for a room rather than a primary...

Page 7: ...onstruction unless provisions are provided for adequate combustion and ventilation air Adjoining rooms are communicating only if there are doorless passageways or ventilation grills between them Unusu...

Page 8: ...r from Outdoors page 9 b Vent room directly to the outdoors See Ventilation Air from Outdoors page 9 c Install a lower BTU hr heater if lower BTU hr size makes room unconfined If the actual Btu Hr use...

Page 9: ...ater in a bedroom or bathroom in a recreational vehicle where curtains furniture clothing or other flammable objects are less than 42 inches from the front top or sides of the heater in high traffic a...

Page 10: ...must be installed INSTALLATION ITEMS NEEDED Before installing heater make sure you have the items listed below piping check local codes sealant resistant to propane LP gas equipment shutoff valve tes...

Page 11: ...RTANT Install equipment shutoff valve in an accessible location The equipment shutoff valve is for turning on or shutting off the gas to the appliance Apply pipe joint sealant lightly to male threads...

Page 12: ...election valve must be locked into either the NG position Do not operate heater between locked positions 3 Rotate and close cover over gas selection valve and reinstall screw 4 Remove steel or metal h...

Page 13: ...quid soap and water to all joints Bubbles forming show a leak Correct all leaks immediately Pressure Testing Heater Gas Connections 1 Open equipment shutoff valve see Figure 11 2 Open gas supply tank...

Page 14: ...so reposition logs according to the log installation instructions in this manual Flames contacting logs will create soot IMPORTANT Make sure log does not cover any burner ports see Figure 13 It is ver...

Page 15: ...rebox floor STEP 5 Insert the recessed hole on the bottom of log 5 onto the pin on log 2 with the other end of log 5 placed on log 3 as shown STEP 4 Insert the recessed hole on the bottom of log 4 ont...

Page 16: ...our hand to push in control knob Never use tools If the appliance could not operate do not try to repair it Call a qualified service technician or gas supplier Forced or attempted re pair may result i...

Page 17: ...n released contact a qualified service person or gas supplier for repairs 8 With control knob pressed in push and hold ignitor button This will light pilot The pilot is attached to the rear of the fro...

Page 18: ...ows an incorrect pilot flame pattern The incorrect pilot flame is not touching the thermocouple This will cause the thermocouple to cool When the thermocouple cools the heater will shut down If the pi...

Page 19: ...ow air through the ports slots and holes in the burner 4 Check the injector holder located at the end of the burner tube again Remove any large particles of dust dirt lint or pet hair with a soft clot...

Page 20: ...s broken 3 Ignitor electrode is not connected to ignitor cable 4 Ignitor cable is pinched 5 Damaged ignitor cable 6 Bad piezo ignitor 7 Low battery 1 Replace ignitor 2 Replace electrode 3 Reconnect ig...

Page 21: ...aintenance Page 19 replace 2 Contact Dealer or Customer Service 3 Replace gas regulator High yellow flame during burner combustion 1 Gas selection valve not set correctly 2 Dirty or clogged burner 3 N...

Page 22: ...while pressing ignitor button 3 Air in gas lines when installed 4 ODS pilot is clogged 5 Gas regulator setting is not correct 6 Bad piezo ignitor 7 Depleted gas supply 1 Turn on gas supply of open eq...

Page 23: ...ervice or your dealer have ready Your name Your address Model and serial number of your heater How heater was malfunctioning Type of gas used Propane LP or Natural gas NG Purchase date Usually we will...

Page 24: ...SCRIPTION QTY 1 PSD20T230 Burner Assembly 1 2 NDD0308 DF ODS 1 3 SIT545 200 T Stat Valve 1 4 AL092 01 Piezo Ignitor 1 5 RV83FI 4 9 DF Regulator 1 6 YDF06 Gas Selection Valve 1 7 ED200T2320 Main Outlet...

Page 25: ...1 13 ED200L14 04 O Decorative Column Caps 4 14 ED200L14 04 C Decorative Column Caps 4 15 ED200T2002 Top Panel 1 1 16 ED200T2001 Body Boarding 1 1 17 ED200T2003 Bottom Panel 1 1 18 ED200T2040 Firebox...

Page 26: ...EDP200T2 O EDP200T2 C 26...

Page 27: ...D200T2003 Bottom Panel 1 9 ED200T2040 Firebox Assembly 1 10 EL010 01C 01 Top Decorative Panel 1 11 EL002 01A 01 Upper Louver 1 12 EL003 01A 01 Mid Louver 1 13 PSD20T201 Burner Pan 1 14 AN LI200MV 202...

Reviews: