Procom EDP200T2-C Manual Download Page 1

 
 
 

                               

 
 
 
 
 

 

 

 

 

 

 

 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 

Questions about installation, operation, or troubleshooting?

 

 Before returning to your retailer, contact our  

customer service department at 1-877-886-5989, 8:00 a.m. - 4:30 p.m., EST, Monday-Friday or e-mail 
[email protected]   

 

ED200T2 651-0903 

 

CAUTION 

 FOR YOUR SAFETY

 

 

 

 
 
 
 

 

 

Do not store or use gasoline or other flammable vapors and liquids in vicinity of 
this or any other appliance. 

 

WHAT TO DO IF YOU SMELL GAS 

·

 

Do not try to light any appliance. 

·

 

Do not touch any electrical switch; do not use any phone in your building. 

·

 

Immediately call your gas supplier from a neighbor

s phone. Follow the gas 

supplier

s instructions. 

·

 

If you cannot reach your gas supplier, call the fire department. 

 

   Installation and service must be performed by a qualified installer, service agency 

or the gas supplier. 

INSTALLER: DO NOT DISCARD THIS MANUAL 

 LEAVE FOR HOMEOWNER

FUTURE REFERENCE. 

 

WARNING: IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED 
EXACTLY, A FIRE MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL 
INJURY, OR LOSS OF LIFE.

 

This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is 
installed. Provisions for adequate combustion and ventilation air must be provided. 
Refer to 

Air for Combustion and Ventilation

 section on page 7 of this manual. 

This appliance may be installed in an aftermarket*, permanently located manufactured 
(mobile) home, where not prohibited by local codes. This appliance is only for use with 
the type of gas indicated on the rating plate. This appliance is not convertible for use 
with other gases. 

WARNING:  

This appliance is 

equipped for (Natural and 
Propane) gas. Field conversion is 
not permitted other than between 
natural or propane gases. 

VENT-FREE FIREPLACE 

MODEL # EDP200T2-O 
                 EDP200T2-C 
                 EDS200T2-HC 

Summary of Contents for EDP200T2-C

Page 1: ...y or the gas supplier INSTALLER DO NOT DISCARD THIS MANUAL LEAVE FOR HOMEOWNER S FUTURE REFERENCE WARNING IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY A FIRE MAY RESULT CAUSING PROPERTY D...

Page 2: ...ONS MODEL EDP200T2 C EDP200T2 O EDS200T2 HC Input Max 20 000 BTU Hr 19 000 BTU Hr 20 000 BTU Hr 19 000 BTU Hr Input Min 11 500 BTU Hr 16 500 BTU Hr 11 500 BTU Hr 16 500 BTU Hr Gas Type Natural LP Prop...

Page 3: ...It is your guide to safe and proper operation of this heater Make certain you read and understand all warnings Keep this manual for reference It is your guide to safe and proper operation of this hea...

Page 4: ...mbustion and Ventilation pages 7 through 9 If heater keeps shutting off see Troubleshooting pages 20 through 22 10 Do not run heater Where flammable liquids or vapors are used or stored Under dusty co...

Page 5: ...ts The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts Sellers of unvented propane or natural gas fired supplemental room heaters shall provide to ea...

Page 6: ...eater produces approximately one 1 ounce 30ml of water for every 1 000 BTU s 3KW s of gas input per hour Unvented room heaters are recommended as a supplemental heater for a room rather than a primary...

Page 7: ...onstruction unless provisions are provided for adequate combustion and ventilation air Adjoining rooms are communicating only if there are doorless passageways or ventilation grills between them Unusu...

Page 8: ...r from Outdoors page 9 b Vent room directly to the outdoors See Ventilation Air from Outdoors page 9 c Install a lower BTU hr heater if lower BTU hr size makes room unconfined If the actual Btu Hr use...

Page 9: ...ater in a bedroom or bathroom in a recreational vehicle where curtains furniture clothing or other flammable objects are less than 42 inches from the front top or sides of the heater in high traffic a...

Page 10: ...must be installed INSTALLATION ITEMS NEEDED Before installing heater make sure you have the items listed below piping check local codes sealant resistant to propane LP gas equipment shutoff valve tes...

Page 11: ...RTANT Install equipment shutoff valve in an accessible location The equipment shutoff valve is for turning on or shutting off the gas to the appliance Apply pipe joint sealant lightly to male threads...

Page 12: ...election valve must be locked into either the NG position Do not operate heater between locked positions 3 Rotate and close cover over gas selection valve and reinstall screw 4 Remove steel or metal h...

Page 13: ...quid soap and water to all joints Bubbles forming show a leak Correct all leaks immediately Pressure Testing Heater Gas Connections 1 Open equipment shutoff valve see Figure 11 2 Open gas supply tank...

Page 14: ...so reposition logs according to the log installation instructions in this manual Flames contacting logs will create soot IMPORTANT Make sure log does not cover any burner ports see Figure 13 It is ver...

Page 15: ...rebox floor STEP 5 Insert the recessed hole on the bottom of log 5 onto the pin on log 2 with the other end of log 5 placed on log 3 as shown STEP 4 Insert the recessed hole on the bottom of log 4 ont...

Page 16: ...our hand to push in control knob Never use tools If the appliance could not operate do not try to repair it Call a qualified service technician or gas supplier Forced or attempted re pair may result i...

Page 17: ...n released contact a qualified service person or gas supplier for repairs 8 With control knob pressed in push and hold ignitor button This will light pilot The pilot is attached to the rear of the fro...

Page 18: ...ows an incorrect pilot flame pattern The incorrect pilot flame is not touching the thermocouple This will cause the thermocouple to cool When the thermocouple cools the heater will shut down If the pi...

Page 19: ...ow air through the ports slots and holes in the burner 4 Check the injector holder located at the end of the burner tube again Remove any large particles of dust dirt lint or pet hair with a soft clot...

Page 20: ...s broken 3 Ignitor electrode is not connected to ignitor cable 4 Ignitor cable is pinched 5 Damaged ignitor cable 6 Bad piezo ignitor 7 Low battery 1 Replace ignitor 2 Replace electrode 3 Reconnect ig...

Page 21: ...aintenance Page 19 replace 2 Contact Dealer or Customer Service 3 Replace gas regulator High yellow flame during burner combustion 1 Gas selection valve not set correctly 2 Dirty or clogged burner 3 N...

Page 22: ...while pressing ignitor button 3 Air in gas lines when installed 4 ODS pilot is clogged 5 Gas regulator setting is not correct 6 Bad piezo ignitor 7 Depleted gas supply 1 Turn on gas supply of open eq...

Page 23: ...ervice or your dealer have ready Your name Your address Model and serial number of your heater How heater was malfunctioning Type of gas used Propane LP or Natural gas NG Purchase date Usually we will...

Page 24: ...SCRIPTION QTY 1 PSD20T230 Burner Assembly 1 2 NDD0308 DF ODS 1 3 SIT545 200 T Stat Valve 1 4 AL092 01 Piezo Ignitor 1 5 RV83FI 4 9 DF Regulator 1 6 YDF06 Gas Selection Valve 1 7 ED200T2320 Main Outlet...

Page 25: ...1 13 ED200L14 04 O Decorative Column Caps 4 14 ED200L14 04 C Decorative Column Caps 4 15 ED200T2002 Top Panel 1 1 16 ED200T2001 Body Boarding 1 1 17 ED200T2003 Bottom Panel 1 1 18 ED200T2040 Firebox...

Page 26: ...EDP200T2 O EDP200T2 C 26...

Page 27: ...D200T2003 Bottom Panel 1 9 ED200T2040 Firebox Assembly 1 10 EL010 01C 01 Top Decorative Panel 1 11 EL002 01A 01 Upper Louver 1 12 EL003 01A 01 Mid Louver 1 13 PSD20T201 Burner Pan 1 14 AN LI200MV 202...