background image

Additional Memory Function of the Profoscope

+

Select memory card symbol to activate the data storage 
mode. 

Minimum cover function is automatically deactivated if the 
memory function is turned on.

Two different memory functions are supported:

Manual:

 After locating, cover value and rebar diameter can 

be stored by the operator.   

Auto: 

Used for surface scans. Every time a rebar is de-

tected, the cover value is stored automatically.

After selecting the memory function, the status line on the measuring screen is modified: 

 Manual Storage Mode
 Automatic Storage Mode
 Memory card missing or defective

Object number  

 

(max.500)  

Measurement number 

(max.99)

It is recommended to set up a separate object for each structural element (e.g. column, wall). Every 
measuring position on this object can then be assigned to a measurement number.

 

Manual Storage Mode: 

Estimate diameter and store values

Delete last measurement

Open next object

Automatic Storage Mode:

Start / Stop automatic storage 
(  blinking while recording)

Open next object

Delete last object

 

Rebar diameter is not stored in the automatic mode. 

Quick Reference Guide to the ProfoLink

Installation

Locate the file „Profolink_Setup“ on your computer or the CD and follow the installation wizard. 
Open the battery compartment and connect the Profoscope

+

 to the USB port. If the icon 

 appears 

on the Profoscope

+

 screen, the connection is established properly.

1

6

5

4

2

3

8

7

1.  Download objects from the Profoscope

+

2.  Expand object to see details
3.  Measurement number
4.  Cover value

5.  Rebar diameter
6.  Add object name
7.  Switch between regional settings or units
8.  Add comments 

“Add” function synchronizes data between PC 
and Profoscope

+

. In addition, locally stored data 

files can be added to an existing project.  

Select the menu “delete all objects” to delete all 
data stored on Profoscope

+

. This will delete all 

objects and cannot be undone. 

Data Management and File structure:

Profoscope

+

Measurements
(max.99)

Objects (*.csv)
(max.500)

PC / ProfoLink

Objects (*.csv)

Projects (*.pqs)

Reviews: