background image

7

PROBRITE.COM

Please call 1-844-507-5651 or email [email protected] for further assistance.

6

Visit 

www.probrite.com/install

 for installation video tutorials and product support

Installation (continued)

3A

Mounting Direct Surface/
Junction Box

 

Mark mounting holes on the surface 
of the wall or ceiling (outside of the 
internal junction box, if applicable)

 

Pre-drill holes into the mounting          
surface

 

Make electrical connections per the 
wiring instructions on stet 4A. 

 

Use suitable screws/bolts for the 
mounting surface (screws provided by 
others) 

 

Place gasket (CC) between the fixture 
and mounting surface

 

Secure the fixture by tightly screwing it 
into the surface firmly

 

See step 7 for chualking instructions

Wiring instructions

 

If necessary, strip 3/8" of insulation 
from junction box or fixture (A) wires 
(fig 2). 

 

Connect 

fixture black wire to house 

black wire

, the (+) line, and 

fixture 

white wire to house white wire

, the (-) 

common by twisting the exposed wires 
together and using the wire nuts (AA). 
Ensure no loose wires.

 

Connect 

house ground wire to the 

green fixture ground wire

, by twisting 

the exposed wires together and using 
the wire nuts (AA). 

LIGHTING 

FIXTURE

(+) LINE

(-) COMMON

GROUND

BLACK

WHITE

GREEN

(fig 2).

4A

Electrical wiring

Installation (continued)

TIP: 

Hold stripped ends near each other and 

align any frayed strands (do not twist wires).

Push the wires into wire nut (BB) and use your 

fingers to twist the wire nut clockwise until tight. 

Check for tightness by pulling wires.

TURN PAGE

For Side Entry Conduit Surface Mounting

Follow Instructions Below for Direct Surface Mounting

Direct to Surface Mounting

B

CC

Internal Junction Box 

(if present)

Mounting 

screws 

provided 

by others

NOTE: 

Mounting holes should be drilled outside 

internal junction box (if present) for most 

junction boxes

AA

B

(fig 1).

CC

 

Pull the wires from the back of the 
fixture and thread through the gasket 
(DD). (Fig. 1)

 

Make wiring connections (see 
wiring instructions below) and place 
connected wires inside the fixture's 
junction box (B)

Summary of Contents for VPR14-4K-WM-GR

Page 1: ...Parts Need Accessories Visit us online anytime or call us to get information on our product range download detailed spec photometric files find product and mounting accessories view installation tutor...

Page 2: ...e product WARNING Turn the power off at the circuit breaker or fuse Place tape over the circuit breaker switch and verify power is off at the light fixture WARNING Risk of fire Keep the lamp heads at...

Page 3: ...A Direct to Surface Junction Box This fixture includes an external junction box to mount anywhere Fixture can also be mounted on top of recessed junction box may requiring tapping hole in fixture base...

Page 4: ...ouse white wire the common by twisting the exposed wires together and using the wire nuts AA Ensure no loose wires Connect house ground wire to the green fixture ground wire by twisting the exposed wi...

Page 5: ...re guard C from the heat sink D by loosening the locking screw using the allen key BB Fig 1 Remove the globe A from the heat sink D by unscrewing it Fig 1 Remove the reflector from the heat sink D by...