background image

1)

 

Press “ON/OFF”

turn off the IR Remote

 

Press “ON/OFF” again

recover to the previous state. 

2)

  When in OFF state, press down 

“9” + “8” + “7” respectively to recover factory settings. 

3)

  Once recover the factory settings, wireless DMX is open to receive signals. Need to reset the 

parameter according to your application.   

 

Operation Instruction 

1. Charging: 

1)  The device equipped with a 11.1V/12AH lithium battery; 

2)  Please recharge in time when the battery is in low power or out of power; if does not use this device 

for long time, please charge at least once within one month, in order to prevent the lithium electricity 

from causing and damaging because of excessive consumption. 

3)  Lithium battery charging time should not more than 24 hours. 

4)  After cycle use 300 times, battery capacity will be reduced to about 8AH

70% of the total capacity

please reduce the charge and discharge times, to extend battery lifetime; after 300 times charging 

and discharging, need to replace the battery, in order not to affect use. 

5)  Lithium battery cannot separate charge take out from the device. 

 

2. Temperature Control Protection 

1) When the temperature of LED board is more than 60 Celsius degree, or the Thermistor check fails, the 

device will start the high temperature protection, reduce power output automatically. 

Thermistor  test  failures:  Thermistor  damaged,  or  the  Thermistor  connected  abnormally,  or  single  chip 

microcomputer port damaged. 
2) “Detection” and display when device power on:   
When  the  device  power  off,  then  turning  on  the  power  supply  in  two  seconds,  the  device  will  detect 

temperature control work condition. 

3) The Red Indicator Light 

Two seconds prior to power, the Thermistor test failures, the red light will light up.   

The Thermistor is working normally, the light is off.   

4) LCD display 
Press  the  “MODE”  button  and  then  power  on.  If  the  temperature  control  working  normal,  will  display 
“Check-up Tr1:    xx”

xx is the current LED board temperature value

; if the temperature control working 

abnormal, will display 

“Check-up Tr1: Er”. 

5) In the process of using, the brightness of abnormal device is far below the normal device. Please test 

the temperature condition before use. 

 

3. Wireless DMX connection 

The device using 2.4GHz wireless r

eceiving module “Pico G4 Receiver, 2.45GHz”, provided by Swedish 

WIRELESS SOLUTION, with only a 2.45 GHz wireless signal receiving function. In order to match using, 
please choose “Black Box F-1 G4 MK2” provided by WIRELESS SOLUTION; 
The status indicator of wireless communication: through an LED indicator light display 

1) No emitter matching: indicator light goes out for a long time; 

2) Matching with one emitter, but loss signal communication: the indicator light will lighting for 100ms, and 

then put out for 100ms, will flicker quickly. 