35
Bilge Pump 2 is a high water bilge pump. The float switch for this pump is located aft of the port battery
trays.
Fish Boxes with Macerator Pumps
Your boat is equipped with port and starboard fish boxes with a
total capacity of 125 gallons. Two 5.0 macerator pumps drain the
fish boxes and/or macerate any fish particles. The pumps are
mounted to the outside of the port and starboard aft stringers.
As the fish boxes drain, water and/or debris travels to the pump
where any debris is macerated and then pumped overboard.
The fish box macerator pumps operate on individual 2-way rocker switches located on the switch panel.
They are labeled port fishbox pump out and starboard fishbox pump out. To properly operate the fish box
macerator pump, fill one of the fish boxes with water. Then, press the applicable fish box switch on the
switch panel in the forward position to operate the pump. The water and fish particles will be pumped out
of the tub and will be routed through the macerator pump and then overboard via the applicable fish box
thru hull on the side of the boat. When you are finished emptying the fish box, place the fish box switch in
the aft position to turn off the fish box macerator pump. Repeat this process for the other fish box.
Washdown Pump and Raw Water Washdown
The washdown pump is
mounted on the starboard aft stringer and is equipped with a pressure switch.
This pump shares the same seacock with the baitwell pump and is accessible via the bilge hatch.
Note: Before operating the washdown pump, make sure that the seacock at the baitwell
pump is in the open position before turning on the pump. The seacock is wide open
when the seacock lever is in the vertical position. When the seacock lever is in the
horizontal position, the seacock is closed. The seacock should remain closed when the
baitwell or washdown pumps are not in use.
The washdown fitting is mounted below the bait station, aft of the helm seat. Just attach a garden hose to
the fitting and the washdown system is ready for use. To turn on the washdown pump, locate the
washdown switch on the instrument panel and press the switch to the forward position. If you do not feel
pressure after pressing the washdown pump switch, the seacock may not be open. Verify that the
Forward Bilge
Pump with
Float Switch
Bilge Pump 2
(High Water Pump)
Float Switch is
mounted aft of the
port battery tray
Bilge Pump 1
with Float
Switch
Raw Water
Washdown
Fitting
Raw Water
Washdown