31
•
Main cabin sink in the galley
•
Head sink and/or shower
•
Transom sink
Turn on the fresh water switch located on the AC/DC panel to blow out any air that may be trapped in the
water lines. When you turn on any of the faucets, you will hear the pump run.
Fresh Water Faucet in Main Cabin (Hot & Cold)
The fresh water faucet for the main cabin is located at the galley sink. See the section titled Fresh Water
Pump for operating instructions before using this faucet.
Fresh Water Faucet with Pull Out Shower in Head (Hot & Cold)
The fresh water faucet with pull out shower is located at the head sink. When doubling as a showerhead,
pull the faucet/nozzle from the sink and place it in the fitting on the forward head wall. See the section
titled Fresh Water Pump for operating instructions before using this faucet/nozzle.
Fresh Water Faucet at Transom Sink (Cold)
The fresh water system hose is located in the transom sink behind a
white rubber cap/cover. Pull open the cap and pull out the
faucet/shower nozzle and hose. Press the button on the nozzle to
ensure proper operation (water spraying). When you are finished,
stow away the transom fresh water hose and cover the outlet with the
white rubber cap.
See the section titled Fresh Water Pump for operating instructions before using this shower.
Shower System and Shower Sump Pump
The shower sump pump is used to pump out any gray water (used water)
from the system. The pump is located inside the cabin and is accessible
through the mid-berth access hatch under the mattress. Water from the sink
and floor drains, in the head area, is pumped out via this system. Under
normal operations, as water drains through the sink and shower drains, the
float switch activates the pump and allows the gray/used water to be pumped
overboard.
To operate the shower system and the sump pump, go to the AC/DC panel in the cabin, locate the DC
main, sump pump and fresh water switches and move them all to the on position. Visually inspect the
sump pump to ensure it is properly secured and listen to hear the pump running. When you have finished
using the sump pump system, turn all switches (DC main, sump pump and fresh water) back to the off
position
Water Heater (Optional)
The optional 6-gallon capacity water heater is located in the cabin
behind the hatch mounted on the forward wall in the mid berth.
To operate the water heater, locate the water heater and the AC main
switches on the AC/DC panel and turn them both to the on position.
Allow the water heater pump to operate for a couple of minutes then
turn on the hot water faucet either in the galley or in the head to
check the water temperature. When finished, turn off all the water
faucets along with the water heater and DC main switches on the