Changing replay speed
To play records at 45 r.p.m. first remove the platter (5). Using the accessory tool provided (3a), hook the belt
(3) over the larger diameter part of the motor pulley (2). Refit the platter. To revert to 33 r.p.m. repeat the
proceedings using the smaller step on the pulley.
Fitting and connecting the cartridge
** All cartridges with half inch mounting holes can be fitted. Leaving the needle's protection cover on, fit the
cartridge to the headshell using the screws supplied with the cartridge by passing one screw through each
slot in the headshell (20). Do not tighten the nuts yet.
Connect the tonearm wires to the cartridge pins as follows:
white
left channel positive (L+)
red
right channel pos. (R+)
green
right channel return (R -)
blue
left channel return (L -)
The full sound quality of the record player can only be achieved if the cartridge is correctly adjusted. Particular
tools like the Pro-Ject alignment tool are required to accomplish this job properly.
If you are not well acquainted with the adjustment of cartridges you are advised to call upon the willing help of
your Pro-Ject dealer to accomplish this task for you.
Please note: Adjusting a cartridge and tonearm calls for the greatest care in order to avoid damaging
the cartridge or tonearm bearings. Leave this work to your dealer if you are in any way unsure of the
necessary steps and precautions to be taken.
Adjusting the azimuth
** The cartridge needle must be vertical in the record groove in order to trace the
groove wall modulations correctly.
A small screw at the bearing end of the arm allows incorrect azimuth to be
corrected if your needle is not mounted exactly perpendicular to the cartridge body
(which is often the case).
Slacken off the screw just enough to be able to revolve the arm tube without
applying force. Please note: do not remove the screw completely!
Screw
With the aid of a good magnifying glass adjust the needle until it is vertical in the groove (i.e. perpendicular
to the record's surface). Ideally this should correspond to the top surface of the cartridge body being parallel
to the record surface.
When you are satisfied that the needle is vertical retighten the screw carefully.
Please note: Under no circumstances should the arm tube be adjusted with the needle still in the
record groove! Irreparable damage may be caused to the cantilever suspension! The arm must be
lifted to make each adjustment and lowered afterwards to check it.
Maintenance and cleaning
Your record player requires little or no regular maintenance. Remove dust with a slightly moistened antistatic
cloth. Never use a dry cloth because this will create static electricity which attract more dust! Antistatic
cleaning fluids are available at specialist stores but must be applied sparingly to avoid damage to rubber
parts. It is recommended to fit the needle cover before cleaning or maintenance is carried out to avoid damage.
If the player is not used over a long period of time the drive belt can be removed to prevent unequal stretching.
!