background image

2

Part Names and Functions

Name

Description

A Status  LED

B CF Card Access LED

Lit in green when the CF Card is inserted and the cover 
is closed, or when the CF Card is being accessed.

C Power Connector (Socket)

-

D USB Host Interface (USB)

USB1.1 Host I/F
Connector: USB TYPE-A x 1
Power supply voltage: 5VDC±5%
Output current: 500mA (max.)
The maximum communication distance: 5m

E Serial Interface (COM1)

Dsub 9-pin plug type. RS232C is supported.

F Serial Interface (COM2)

Dsub 9-pin plug type. RS422/RS485

*1

 is supported.

*1 RS485 is compliant with ST-3400 series units with revision code “A” or later.

 

 

Revision (page 11)

G CF  Card  Cover

-

H Dip Switches

Located inside the CF Card Cover.

Front

Rear

Right Side

Bottom

(CF Card Cover Open)

A

B

E

F

C

D

G

H

LED

ST Status

Green (lit)

Normal operation (power is ON.) or 
OFFLINE operation.

Orange

 

(blinking)

During software startup.

Red (lit)

When power is turned ON. 

Not lit

Power is OFF.

SEE

Summary of Contents for ST-3400 Series

Page 1: ...with special attention to quality However should you find anything damaged or missing please contact your local ST distributor immediately About the Manual For the detailed information on ST3000 serie...

Page 2: ...tion distance 5m E Serial Interface COM1 Dsub 9 pin plug type RS232C is supported F Serial Interface COM2 Dsub 9 pin plug type RS422 RS485 1 is supported 1 RS485 is compliant with ST 3400 series units...

Page 3: ...mA for 1minute between charging and FG terminals Insulation Resistance DC500V 10M min between charging and FG terminals Physical Surrounding Air Temperature 0 to 50 C Storage Temperature 20 to 60 C Am...

Page 4: ...2 01 on COM1 COM1 Recommended Cable Connector XM2D 0901 made by OMRON Corp Recommended Jack Screw XM2Z 0073 made by OMRON Corp Recommended Cable Cover XM2S 0913 made by OMRON Corp Interfit Bracket 4 4...

Page 5: ...inch screws are used Pin RS422 RS485 1 1 RS485 is compliant with ST 3400 series units with revision code A or later Revision page 11 Signal Name Meaning 1 RDA Receive Data A 2 RDB Receive Data B 3 SDA...

Page 6: ...tallation 1 Create a Panel Cut following the dimen sions in the table below 2 Confirm that the installation gasket is attached to the ST unit and then place the ST unit into the Panel from the front I...

Page 7: ...ble Power Cord Specifications Use copper conductors only Power Connector Plug Specifications The power connector plug is CA5 DCCNM 01 made by Pro face or MSTB2 5 3 ST 5 08 made by Phoenix Contact Inse...

Page 8: ...e bundled with or kept close to main circuit lines high voltage high current or input output signal lines To reduce noise make the power cord as short as possible If the supplied voltage exceeds the S...

Page 9: ...ire with a thicker wire and place it in a duct 4 Input Output Signal Line Cautions All ST Input and Output signal lines must be separated from all operating circuit power cables If this is not possibl...

Page 10: ...wing items when building the ST into an end use product The ST unit s rear face is not approved as an enclosure When building the ST unit into an end use product be sure to use an enclosure that satis...

Page 11: ...o higashi Suminoe ku Osaka 559 0031 JAPAN TEL 81 0 6 6613 3116 FAX 81 0 6 6613 5888 http www pro face com Copyright 2007 Digital Electronics Corporation All rights reserved 085893E AST3400 MT01E BTH 2...

Reviews: