ST-3400 Series

Installation Guide

Package Contents

(1) ST Unit (1)

(2) English and Japanese Installation Guides 

(one of each) <This Guide>

(3) Warning/Caution Information (1)

(4) Installation Gasket (1) 

 

(Attached to the ST unit)

(5) Installation Fasteners (Set of 4) 

(6) Power Connector (1) 

(7) USB Cable Clamp (1 set)

 

(Holder: 1, Cover: 1)

This unit has been carefully packed, with 
special attention to quality. However, should 
you find anything damaged or missing, 
please contact your local ST distributor 
immediately.

About the Manual

For the detailed information on ST3000 
series, refer to the following manual.

ST3000 Series Hardware Manual

Maintenance/Troubleshooting

ST3000 Series Hardware Manual can be 
selected from the help menu of GP-Pro EX or 
downloaded from Pro-face Home Page.

URL

http://www.pro-face.com/otasuke/

Caution

Be sure to read the “Warning/Caution 
Information” on the attached sheet before 
using the product.

Summary of Contents for ST-3400 Series

Page 1: ...with special attention to quality However should you find anything damaged or missing please contact your local ST distributor immediately About the Manual For the detailed information on ST3000 serie...

Page 2: ...tion distance 5m E Serial Interface COM1 Dsub 9 pin plug type RS232C is supported F Serial Interface COM2 Dsub 9 pin plug type RS422 RS485 1 is supported 1 RS485 is compliant with ST 3400 series units...

Page 3: ...mA for 1minute between charging and FG terminals Insulation Resistance DC500V 10M min between charging and FG terminals Physical Surrounding Air Temperature 0 to 50 C Storage Temperature 20 to 60 C Am...

Page 4: ...2 01 on COM1 COM1 Recommended Cable Connector XM2D 0901 made by OMRON Corp Recommended Jack Screw XM2Z 0073 made by OMRON Corp Recommended Cable Cover XM2S 0913 made by OMRON Corp Interfit Bracket 4 4...

Page 5: ...inch screws are used Pin RS422 RS485 1 1 RS485 is compliant with ST 3400 series units with revision code A or later Revision page 11 Signal Name Meaning 1 RDA Receive Data A 2 RDB Receive Data B 3 SDA...

Page 6: ...tallation 1 Create a Panel Cut following the dimen sions in the table below 2 Confirm that the installation gasket is attached to the ST unit and then place the ST unit into the Panel from the front I...

Page 7: ...ble Power Cord Specifications Use copper conductors only Power Connector Plug Specifications The power connector plug is CA5 DCCNM 01 made by Pro face or MSTB2 5 3 ST 5 08 made by Phoenix Contact Inse...

Page 8: ...e bundled with or kept close to main circuit lines high voltage high current or input output signal lines To reduce noise make the power cord as short as possible If the supplied voltage exceeds the S...

Page 9: ...ire with a thicker wire and place it in a duct 4 Input Output Signal Line Cautions All ST Input and Output signal lines must be separated from all operating circuit power cables If this is not possibl...

Page 10: ...wing items when building the ST into an end use product The ST unit s rear face is not approved as an enclosure When building the ST unit into an end use product be sure to use an enclosure that satis...