4

Installation

 Attach the GP's Installation Fasteners from inside the panel.

Tighten the installation fasteners with a standard screwdriver.

Tightening the fastener screws with too much force can damage the
GP's case. The torque necessary to ensure a waterproof seal is 0.5 to
0.6N•m.

156

under 4-R3

123.5

Panel thickness should be
from 1.6mm to 5.0mm

Unit: mm

 +1

0

 +1

0

GP Unit

 Cut a hole in the metal panel according to the dimensions given below.

Insert the GP into the panel from the front of the panel.

Metal Panel

Please be sure the gasket has been installed on the GP before
installing the GP.

Follow the steps given below when installing the GP unit.

 Confirm the Moisture Resistant Gasket’s Seating

Moisture resistant
gasket

It is strongly recommended that you use
the gasket. When seating the gasket,
place the GP on a level surface with the
display panel facing downward.  Check
that the GP’s moisture resistant gasket is
seated securely into the gasket’s groove,
which runs around the perimeter of the
panel’s frame.

Rear face

Summary of Contents for GP377R-TC11-24V

Page 1: ...on due to a communication fault between the GP and its host controller To Prevent From Damage WARNING Do not strike the GP s touch panel with a hard or heavy object or press on the touch panel too strongly since it may damage the display Do not install the GP where the temperature will exceed its specified range Be sure that water liquids or metal particles do not enter the GP since it may cause a...

Page 2: ...stributor imme diately GP 377R Series User s Manual 1 Sold Separately GP Options Made by Digital Cables Adapters Screen editor software etc For more information on these items please refer to Digital s GP catalogues GP Unit 1 GP377R TC11 24V Installation fasteners 4 Digital GP 377R Series User s Manual 1 Please refer to this manual for detailed product information Installation Guide 1 This Guide G...

Page 3: ...Connects each optional GP Expansion Unit to the GP inside cover F Serial Interface Connects an RS 232C or RS 422 Serial cable from the host PLC to the GP G Tool Connector Connects a Data Transfer Cable Bar Code Reader Memory Loader or other equipment to the GP 1 GP 377R Parts Names and Functions D F E A B C G Unit mm Top View SideView 57 5 123 155 5 170 5 Front View 2 GP 377R External Dimensions L...

Page 4: ... Enable Receive RS 232C 21 CSA Clear to Send A RS 422 22 ERA Enable Receive A RS 422 23 BUZZ GND External Buzzer Ground 24 NC No Connection 25 BUZZ OUT External Buzzer Output This interface is used to connect the GP to the host PLC via either an RS 232C or RS 422 cable 3 Serial Interface Recommended Connector Dsub25pinplug XM2A 2501 made by OMRON Corp Recommended Cover Dsub 25 pin Cover XM2S 2511 ...

Page 5: ...onnecting the 9 TRMX and 10 RDA wires adds a termination resistance of 100Ω Ω Ω Ω Ω between RDA and RDB Use a 4 wire cable when the PLC type is Memory Link and the cable is RS 422 For RS 232C Connectors Do not connect 9 TRMX 10 RDA 11 SDA 15 SDB 16 RDB 18 CSB 19 ERB 21 CSA and 22 ERA Since pin 14 is not protected be sure to use it only within its rated range ...

Page 6: ...ng to the dimensions given below Insert the GP into the panel from the front of the panel Metal Panel Please be sure the gasket has been installed on the GP before installing the GP Follow the steps given below when installing the GP unit Confirm the Moisture Resistant Gasket s Seating Moisture resistant gasket It is strongly recommended that you use the gasket When seating the gasket place the GP...

Page 7: ...touseonlyDC24Vinput Anyother power level can damage both the GP and the power supply Be sure to reattach the Power Terminal s clear plastic cover after con necting the Power Cord s power terminals Connecting the GP s Power Cord When connecting the power cable be sure to follow the procedures given below 1 Confirm that the GP s Power Cord is unplugged from the power supply 2 Use a screwdriver to re...

Page 8: ...ide the GP377R TC 24V unit SG Signal Ground and FG Frame Ground termi nals are connected to each other When attaching an expansion unit to the GP be sure to read the expansion unit s Installation Instructions 8 I O Input Output Signal Line Precautions All GP Input and Output signal lines must be separated from all operating circuit power cables If this is not possible use a shielded cable and grou...