Structural Specifications
*1
The front face of the GP unit, installed in a solid panel, has been tested using
conditions equivalent to the standards shown in the specification. Even though the
GP unit’s level of resistance is equivalent to these standards, oils that should have
no effect on the GP unit can possibly harm the panel. This can occur in areas where
either vaporized oils are present, or where low viscosity cutting oils are allowed to
adhere to the panel for long periods of time. If the GP unit’s front face protection
sheet peels off, these conditions can lead to the ingress of oil into the GP unit and
separate protection measures are suggested.
Also, if non-approved oils are present, they may cause deformation or corrosion of
the front panel’s plastic cover. Therefore, prior to installing the GP unit, be sure to
confirm the type of conditions that will be present in the GP unit’s operating
environment. If the installation gasket is used for a long period of time, or if the GP
unit and its gasket are removed from the panel, the original level of protection cannot
be kept. To maintain the original protection level, be sure to replace the installation
gasket regularly.
*2
For dimensional tolerance, ever1/-0 mm (+0.04/-0 in.) and R in angle are
below R3 (R0.12 in.)
*3
Even if the installation wall thickness is within the recommended range for the
“Panel Cut Dimensions”, depending on wall’s material, size, and installation location
of the GP unit and other devices, the installation wall could warp. To prevent
warping, the installation surface may need to be strengthened.
The front face of the panel, installed in a solid panel, has been tested using
conditions equivalent to the standards shown in the specification.
Grounding
Functional grounding: Grounding resistance
of 100
Ω
, 2mm
2
(AWG 14) or thicker wire, or
your country’s applicable standard. (Same
for FG and SG terminals)
Cooling Method
Natural air circulation
Structure
*1
IP65F NEMA #250 TYPE 4X/13 (on the front
panel when properly installed in an
enclosure)
External Dimensions
W132 x H106 x D42 mm (W5.2 x H4.17 x
D1.65 in.)
Panel Cut Dimensions
W118.5 x H92.5 mm (W4.67 x H3.64 in.)
*2
Panel thickness area: 1.6...5 mm (0.06...0.2
in)
*3
Weight
0.4 kg (0.9 lb) or less (main unit only)
CAUTION
EQUIPMENT DAMAGE
Ensure that the panel is not in permanent and direct contact with oils.
Failure to follow these instructions can result in injury or equipment damage.
Summary of Contents for GP-4200 Series
Page 1: ...3 6HULHV DUGZDUH 0DQXDO...
Page 10: ...10...
Page 42: ...Parts Functions 42...
Page 58: ...Specifications 58 Dimensions External Dimensions 1 Front 2 Right Side 3 Top PP LQ...
Page 110: ...Specifications 110 External Dimensions GP 4501TW 1 Front 2 Right Side 3 Top PP LQ...
Page 134: ...Specifications 134...
Page 161: ...GP4000 Series Hardware Manual 161 1 USB clamp 2 USB cable 2 1 1...
Page 162: ...Installation and Wiring 162...