- Do not modify the GLC unit.  Doing so may cause a fire or an

electric shock.

- Do not use the GLC in an environment where flammable gasses

are present, since operating the GLC may cause an explosion.

Wiring Warnings:

- To prevent electric shock or equipment damage, prior to install-

ing or wiring the GLC, confirm that the GLC’s power cord is un-
plugged from the power supply.

- After completing any GLC wiring work, be sure the terminal block’s

protective plastic cover is reattached. If this cover is not reat-
tached, an electric shock could easily occur.

- Do not use power levels with the GLC that are outside of the GLC’s

specified power range. Doing so may cause a fire, electric shock
or damage the GLC.

- Do not operate or store the GLC in areas where flammable gas-

ses are present, since operating the GLC may cause an explo-
sion.

Operation and Maintenance Warnings:

- Do not touch a live power terminal. This could cause a shock or

machine malfunction.

- Due to the danger of an electric shock, confirm that the GLC’s

power cord is unplugged before either cleaning the GLC or at-
taching/detaching the power terminal block screws.

- When replacing the GLC’s backlight, be sure to unplug the unit’s

power cord  to prevent a shock, and wear gloves to prevent being
burned.

- The GLC uses a lithium battery for backing up its internal clock

and control memory data. If the battery is incorrectly replaced
(i.e. the + and - sides are reversed), the battery may explode. There-
fore, before changing the battery, Pro-face recommends that you
contact your local GLC distributor for battery replacement instruc-
tions.

- Do not attempt to modify the GLC’s internal parts or wiring in any

way, since this may lead to either a shock or fire.

CAUTIONS

Wiring Layout Cautions:

- Be sure that all GLC input/output signal lines are isolated from all

power wiring or power cables, via a separate wiring duct. This is
to prevent excessive noise, which can cause a unit malfunction.

Installation Cautions:

- Be sure any data cable attached to a GLC connector is securely

attached. If the cable and connector pins do not all make com-
plete contact, incorrect input or output signals can result.e noise,
which can cause a unit malfunction.

Summary of Contents for GLC2500-TC41-200V

Page 1: ...ternal to the GLC 3 If a problem arises with an external unit s relay or transistor causing an output coil to remain either ON or OFF a major accident can occur To prevent this be sure to set up exter...

Page 2: ...ty and reliability When using the GLC with transportation vehicles trains cars and ships disaster and crime prevention devices various types of safety equipment non life support related medical device...

Page 3: ...rm that the GLC s power cord is unplugged before either cleaning the GLC or at taching detaching the power terminal block screws When replacing the GLC s backlight be sure to unplug the unit s power c...

Page 4: ...e a fire accident or malfunction GLC Operation and Maintenance Cautions Be sure to read the GLC s manual and on line help information carefully before performing program changes forced output or utili...

Page 5: ...install it in a vertical panel Also insure that the GLC is mounted at least 100 mm away from any other adjacent structures or machine parts If these conditions are not met the heat generated by the GL...

Page 6: ...00 3 2 EN61000 3 3 EN61000 6 2 and EN60950 For detailed CE marking information please contact your local GLC distribu tor Cautions The GLC unit s rear face is not approved as an enclosure When buildin...

Page 7: ...udes the performance of ladder circuit program features 3 Changing to OFFLINE will release and stop ladder circuit program features Front Rear Bottom C A B D I E F G H J K L M N O P D Power Input Term...

Page 8: ...d Always OFF 3 Reserved Always OFF 4 This setting controls the forced closing of the CF Card cover Forced close enabled Forced close disabled Used when CF Card cover is damaged 3 CF Card Dip Switches...

Page 9: ...rfaces Recommended Connector Dsub 25 pin plug XM2A 2501 made by OMRON Corp Recommended Cover Dsub 25 pin Cover XM2S 2511 madebyOMRONCorp RecommendedScrew JackScrewXM2Z 0071 madebyOMRONCorp Recommended...

Page 10: ...232C 5 SG Signal Ground 6 DR Data Set Ready RS 232C 7 RS Request to Send RS 232C 8 CS Clear to Send RS 232C 9 RI VCC Ring Indicate RS 232C 5V 5 0 25A Recommended Connector Dsub 9 pin socket XM2D 0901...

Page 11: ...sure to change the gasket peri odically or when scratches or dirt become visible Confirm the Installation Gasket s Positioning It is strongly recommended that you use the gasket It absorbs vibration i...

Page 12: ...lation fastener Panel GLC Insertion Slots Insertion Slots Top Bottom Unit mm in 1 0 0 04 0 u n d e r 4 R 3 Panel Panel thickness 1 6mm 0 06in to 10mm 0 39in 301 5 11 87 GLC GLC Panel 1 0 227 5 8 96 0...

Page 13: ...re attach the screws 4 Replace the Power Input Terminal Block s clear plastic cover Confirm that the ring wires are connected correctly The torque required to tighten these screws is 0 5 to 0 6 N m T...

Page 14: ...f the power cord wires before connecting it to the GLC unit The GLC s power supply cord should not be bundled with or kept close to main circuit lines high voltage high current or input output signal...

Reviews: