14
COZEBURN INSTALLATION AND OPERATION MANUAL
INSTALLATION
Optional Heat Exchanger
Stainless Steel Water to Water Heat Exchanger,
Figure 2, can be used in place of a side arm.
COLD
WATER
MIXED
WATER
TEMPERING VALVE
Hot water
Used for
bleeding air
WATER HEATER
Use for
filling system
Supply
from
furnace
To heating
system
Water heater drain
CAUTION
Do not eliminate
the existing
temperature relief
valve.
SIDE
ARM
HEA
T
EX
CHANGER
NOTE
: Keep bottom loop (and side arm) as low as possible.
PUMP
BALL VALVE
THERMOMETER
BOILER DRAIN
TEMPERING OR
MIXING VALVE
SYMBOL INDEX
Have a qualified electrician
and plumber check to ensure
all connections to the furnace
are in accordance with the
manufacturer’s specifications and
performed by qualified, licensed
personnel in accordance with
local building codes.
Side Arm Installation
To heating
system
Hot water in
from
furnace
To top of hot water tank
From bottom of hot water tank
Figure 1
Figure 2
IMPORTANT
When hooking up
the Cozeburn to a
domestic hot water heater,
a tempering valve must be
installed, to prevent scalding
hot water from reaching the
hot water outlets.
Valve