Pro Charging Systems 4818CC Safety, Installation And Operating Instructions Download Page 7

 

7

 
PROBLEM: A green LED was illuminated before disconnecting the power from the charger, but upon reconnection, 
red LEDs appear and remain on. 

 
This is the normal operating procedure for the system. It indicates that a reanalysis of the battery status was initiated and 
after a series of steps the green LED will illuminate. 

 
LIGHT EMITTING DIODES (LED) FAULT CODE INDICATIONS  

 

The microprocessor is constantly monitoring the charger circuitry and will both detect and display blinking LED indications if a 
fault is detected.  The battery type LED will be 

OFF

 during a fault code condition.   

 
30% RED LED BLINKING .....................................................NO BATTERY DETECTED  
This indication occurs whenever the charger circuitry cannot detect a battery.  The charger circuitry will not allow charge 
current to flow under this condition.  With the AC power supply cord unplugged, check the connection to the batteries for 
proper polarity (black wire to negative or -).  Also check for corrosion free secure connections to the battery.  Please call 
technical support for further assistance (800.742.2740). 
 
30 & 60% RED LEDS BLINKING …………FORMING STAGE TIMEOUT SHUTDOWN  
This indication occurs if the battery voltage has not risen above 1.75 volts per cell within the first 3 hours of charging.  This 
indicates that a possible battery problem exists and that the charge cycle has been terminated at this point.  Please call 
technical support for further assistance (800.742.2740). 
 
30, 60 & 90% RED LEDS BLINKING............................OVERALL TIMER SHUTDOWN  
This indication occurs if the charger has not completed the charge cycle within the allowable factory set time period.  This 
indicates that a possible battery problem exists and that the charge cycle has been terminated at this point.  Please call 
technical support for further assistance (800.742-2740). 
 
30 & 90% RED LEDS BLINKING …..…....................INTERNAL OVERTEMP SHUTDOWN  
This indication occurs if the charger circuitry has detected operating temperatures inside the charger enclosure that are 
above factory specified levels.  This could indicate that a possible charger problem exists and that the charge cycle has been 
terminated.  Please call technical support for further assistance (800.742.2740). 
 
Note: Disconnecting and reconnecting the AC power supply cord will reset the charger. 
 
 

 

LIMITED WARRANTY 

 
Pro Charging Systems, LLC (PCS) makes this Limited Warranty only to the original retail purchaser.   
 
PCS warrants this battery charger for three years from the date of retail purchase against defective materials and/or 
workmanship.  If such defects should occur, this unit will either be repaired or replaced at the discretion of the manufacturer.  
It is the responsibility of the original purchaser to return the charger along with proof of purchase, transportation, and/or any 
mailing or handling charges prepaid to the manufacturer or its authorized representative. 
 
This limited warranty is void if the product is misused, improperly maintained, handled carelessly or incorrectly operated.  
Additionally, this warranty is void if the charger is disassembled, the charger’s charge cables are cut, the power cord is cut 
off, the charger is altered without authorization from PCS, the serial number is removed, or repair is attempted by anyone 
other than an authorized representative.   
 
PCS makes no other warranty other than this limited warranty and expressly excludes any implied warranty, including 
warranty for any incidental or consequential damages. 
 
This is the only expressed limited three year warranty authorized by PCS and does not authorize anyone to assume or make 
any other obligation towards the product other than this three year Limited Warranty.  Some states do not allow limitation of 
incidental or consequential damages. 
 
This warranty gives you specific legal rights and you may also have other rights which vary from state to state. 
 

Summary of Contents for 4818CC

Page 1: ...815OBCC Club Car Applications ________________________________________ 091710 IMPORTANT NOTICE Please save and read these safety operating and installation instructions before installing or applying A...

Page 2: ...ult Code Indications Page 7 Limited Warranty Information Page 7 Special Instructions Page 8 IMPORTANT SAFETY INSTRUCTIONS INSTRUCTIONS IMPORTANTES CONCERNANT LA S CURIT SAVE THESE INSTRUCTIONS This ma...

Page 3: ...Keep work area well lit 8 Do not overreach Keep proper footing and balance at all times Do not reach over or across electrical cables or frames 9 Avoid electrical shock To reduce risk of electrical s...

Page 4: ...ufacturers specific precautions such as removing or not removing cell caps while charging and recommended rates of charge When using an extension cord make sure that pins on plug of extension cord are...

Page 5: ...ce sulfation on the lead plates of the batteries and allow your PCS charging system to keep your batteries fully maintained and ready to perform at their best To reduce the risk of fire use only on ci...

Page 6: ...uitry has determined the batteries to be fully charged The green LED will blink during the finishing stage of the charge cycle After the completion of the charge cycle the green LED will remain on ste...

Page 7: ...L OVERTEMP SHUTDOWN This indication occurs if the charger circuitry has detected operating temperatures inside the charger enclosure that are above factory specified levels This could indicate that a...

Page 8: ...ofile be used instead In our opinion the superior profile provided by DeltaVolt will promote higher specific gravity levels for the batteries which will result in more range and longer battery life Ou...

Reviews: