 Working in the vicinity of a lead-acid battery is dangerous.  Batteries generate explosive gases 

during normal operation.  For this reason it is of the utmost importance that prior to each use of your charger, you 
read and follow the instructions provided exactly. 
 
Il est dangereux de travailler a proximité d’une batterie au plomb.  Les batteries produisent des gaz explosifs en service 
normal.  Il est aussi important de toujours relire les instructions avant d’utiliser le chargeur et de les suivre à la lettre.   
 

CHARGING INDICATIONS 

When your battery charging system is activated, the battery status indicator provides charging information utilizing a 
combination of six LED indicators to display the battery type being charged and the percent of charge on the battery pack. 

 

Battery Type Indicators 

Two LED indicators are provided in order to display what type of charge profile is being 
applied.  

NOTE:

 For information on reconfiguring the charge profile, please contact 

technical support (800.742.2740).  Also see special instructions on page 8.   

Battery System Percent Charged Indicators  

Four LED indicators are provided in order to display the progress of the charge cycle in 
percentage of charge.   

 
Indications are as follows: 
 
1

ST

 LED . . . .  . …. . . . . . 

Illuminated configured for Wet Cell and AGM batteries(Using our DeltaVolt Profile) 

2

ND

 LED ... . . . . . . . . . . . . 

Illuminated configured for Wet Cell and AGM batteries(Using the Club Car Processor)  

3

RD

 LED . . . . . . . . . . . . .  

Charging - Initial Charging Up To 30%  

3

RD

 & 4

TH

 LEDS  . . . . . . .  

Charging - 60% Complete  

3

RD

, 4

TH

 & 5

TH

 LEDS  . . . . 

Charging - 90% Complete  

BLINKING GREEN LED  . . . .   Finishing Stage   
STEADY GREEN LED  . . . . . .  Charge Complete - Monitoring Batteries 
 
The green LED is illuminated whenever the charge cycle has terminated and the internal circuitry has determined the 
batteries to be fully charged. The green LED will blink during the finishing stage of the charge cycle.  After the completion of 
the charge cycle, the green LED will remain on steady during the float-maintenance stage.  

During this final stage current 

is only flowing to the battery system for 5 minutes and then current will stop completely for 60 minutes.   
 
Your system provides an equalization stage every 30 days while plugged in.  If the charger is normally disconnected 
from A/C after completing charge, equalization can be accomplished by plugging back into A/C whenever this stage 
is desired. Battery manufacturers recommend that equalization is done once a month in order to further reduce 
sulfation on the lead plates of a battery, which helps promote longer battery life.  Note:  During this process the 
LEDs will go through their normal routine(Red LEDs counting up for % of charge along with the illuminated  LED 
Battery Type) and then the Green LED and Battery Type LED will blink) until the unit returns to the maintenance 
mode and a steady Green LED and steady Battery Type LED. (Not applicable to Gel Profile) 

TROUBLESHOOTING  

 
PROBLEM: No LED indicators illuminated on battery status indicator. 
 

Solution Sequence: 
1. Confirm that current is being delivered to the charger. Use a meter or test light to check the AC power supply from its 
source through all connecting points up to the charger. 
 
2. Check that the AC circuit breaker (on front of the unit) is depressed. 
 
3. Call technical support for further assistance (800.742.2740). 

 
PROBLEM: The charge status indicator changes rapidly back and forth from red to green or the green LED will not 
illuminate after excessive charging time (24 hours or more). 

 
Solution Sequence: 
1. Disconnect AC power from the charging system. This indication may signify a possible battery problem. 
 
2. Call technical support for further assistance (800.742.2740). 

Summary of Contents for 4818CC

Page 1: ...815OBCC Club Car Applications ________________________________________ 091710 IMPORTANT NOTICE Please save and read these safety operating and installation instructions before installing or applying A...

Page 2: ...ult Code Indications Page 7 Limited Warranty Information Page 7 Special Instructions Page 8 IMPORTANT SAFETY INSTRUCTIONS INSTRUCTIONS IMPORTANTES CONCERNANT LA S CURIT SAVE THESE INSTRUCTIONS This ma...

Page 3: ...Keep work area well lit 8 Do not overreach Keep proper footing and balance at all times Do not reach over or across electrical cables or frames 9 Avoid electrical shock To reduce risk of electrical s...

Page 4: ...ufacturers specific precautions such as removing or not removing cell caps while charging and recommended rates of charge When using an extension cord make sure that pins on plug of extension cord are...

Page 5: ...ce sulfation on the lead plates of the batteries and allow your PCS charging system to keep your batteries fully maintained and ready to perform at their best To reduce the risk of fire use only on ci...

Page 6: ...uitry has determined the batteries to be fully charged The green LED will blink during the finishing stage of the charge cycle After the completion of the charge cycle the green LED will remain on ste...

Page 7: ...L OVERTEMP SHUTDOWN This indication occurs if the charger circuitry has detected operating temperatures inside the charger enclosure that are above factory specified levels This could indicate that a...

Page 8: ...ofile be used instead In our opinion the superior profile provided by DeltaVolt will promote higher specific gravity levels for the batteries which will result in more range and longer battery life Ou...

Reviews: